GE Fanuc IS200TBCIS2CCD – Redundant Fault-Tolerant Processor Module | Mark VI Control System
Engineering Background
The IS200TBCIS2CCD is a critical processor board within GE Fanuc’s Mark VI Turbine Control platform — one of the most widely deployed distributed control architectures in power generation, oil & gas, and heavy industrial environments. Designed for triple-redundant (TMR) and dual-redundant (DMR) configurations, this module ensures continuous process availability even under single-point hardware failure conditions.
Product Positioning
Engineered for procurement engineers and reliability engineers who require a verified, drop-in replacement for aging Mark VI control infrastructure. The IS200TBCIS2CCD eliminates costly OEM lead times while maintaining full backward compatibility with existing I/O racks, communication backplanes, and HMI software environments.
Complete Technical Specifications
- Part Number: IS200TBCIS2CCD
- Manufacturer: GE Fanuc (General Electric Energy Controls)
- Platform / Series: Mark VI Turbine Control System
- Module Type: Redundant Fault-Tolerant Processor / Control Board
- Redundancy Architecture: TMR (Triple Modular Redundancy) / DMR (Dual Modular Redundancy) compatible
- Backplane Interface: Mark VI VME-based I/O backplane
- Communication Protocols: Ethernet (IONET / ARCNET), RS-485 serial
- Operating Voltage: 24 VDC (supplied via backplane)
- Operating Temperature: 0°C to +60°C
- Storage Temperature: -40°C to +85°C
- Humidity: 5% to 95% non-condensing
- Weight: Approx. 300 g
- Form Factor: Single-slot VME board
- Firmware: Compatible with Mark VI standard firmware revisions
- Certifications: CE, UL (per GE Mark VI platform certification)
- HS Code: 8537.10
- Country of Origin: United States
Proven Application Environments
- Gas turbine and steam turbine control (GE Frame 5, 6, 7, 9 series)
- Combined-cycle power plant DCS integration
- Offshore and onshore oil & gas compressor control
- Petrochemical plant safety instrumented systems (SIS) integration
- Industrial boiler management and burner management systems (BMS)
- Water treatment and pumping station automation
- Steel mill and heavy manufacturing process control
Engineering Advantages
- Zero-downtime redundancy: Hot-standby switchover in <1 ms under TMR configuration
- Full backward compatibility: Drop-in replacement for existing Mark VI racks without firmware re-flashing in most configurations
- Diagnostic transparency: Onboard LED fault indicators and self-test routines accessible via ToolboxST
- Long service life: Industrial-grade components rated for 10+ years continuous operation
- Reduced MTTR: Module-level swap reduces mean time to repair versus board-level repair
- Inventory efficiency: Single SKU covers both TMR and DMR slot positions
System Architecture & Signal Flow
Within the Mark VI architecture, the IS200TBCIS2CCD resides in the controller chassis and interfaces with I/O terminal boards (TBCI series) via the VME backplane. The processor executes control logic compiled in ToolboxST, communicates with the IONET Ethernet network for HMI and historian data exchange, and synchronizes with redundant peer modules via the dedicated inter-controller bus. In TMR mode, three IS200TBCIS2CCD modules vote on output commands — any single module failure is masked transparently without process interruption.
Sourcing & Quality Verification
- Source: Decommissioned OEM-maintained plant spares and authorized surplus channels
- Inspection: Full visual inspection, board-level cleaning, and functional power-on test
- Testing: Bench-tested against Mark VI backplane simulator prior to shipment
- Condition: Refurbished / Tested — equivalent to OEM spare performance
- Warranty: 12-month operational warranty from Konmask.com
- Packaging: ESD-safe anti-static bag + foam-lined carton for international transit
- Documentation: Certificate of testing available upon request
Procurement Process
- Confirm compatibility: Verify your Mark VI chassis revision and firmware version with our technical team before ordering.
- Request a quote: Contact support@konmask.com for volume pricing, lead time, and export documentation (CO, packing list, commercial invoice).
- Place order: Secure checkout via Konmask.com — accepts T/T wire transfer, credit card, and PayPal.
- Shipping: DHL / FedEx Express worldwide; typical transit 3–7 business days. Air freight and sea freight available for bulk orders.
- After-sales: 12-month warranty with RMA support. Technical assistance available via email and WhatsApp.
Technical FAQ
Q: Is the IS200TBCIS2CCD compatible with both Mark VI and Mark VIe?
A: The IS200TBCIS2CCD is designed for the Mark VI platform. Mark VIe uses a different controller architecture (IS420 series). Please confirm your system generation before ordering.
Q: Can this module be used in a simplex (non-redundant) configuration?
A: Yes. The module operates in simplex mode when installed as a single controller, though redundancy features will not be active.
Q: Do you provide firmware or ToolboxST configuration support?
A: We supply hardware only. Firmware loading and ToolboxST configuration should be performed by a qualified GE Mark VI system integrator. We can recommend certified partners upon request.
Q: What is the lead time for this part?
A: In-stock units ship within 1–2 business days. Contact us to confirm current stock availability.
Q: Do you accept returns?
A: Yes, within 30 days of receipt for unused/untampered units. Tested units are covered under our 12-month warranty RMA policy.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com