Process Safety Solution – Honeywell 2MLR-CPUH/S-CC | FSC Fail Safe Controller Series
Where This Product Is Used
The Honeywell 2MLR-CPUH/S-CC High Speed CPU Module is the central processing unit of Honeywell’s FSC (Fail Safe Controller) platform — a dedicated safety PLC designed for Safety Instrumented Systems (SIS) in high-hazard process industries. Typical deployment environments include:
- Oil & Gas: Emergency Shutdown Systems (ESD), High Integrity Pressure Protection Systems (HIPPS), and Burner Management Systems (BMS) on offshore platforms and onshore terminals.
- Petrochemical & Refining: Reactor trip systems, compressor protection, and fired heater safety logic.
- Power Generation: Turbine protection, boiler safety interlocks, and grid-connected generator trip logic.
- Chemical Processing: Toxic release prevention, pressure relief override logic, and SIL 2/3 interlock systems.
- LNG & Pipeline: Leak detection, valve control, and station ESD for transmission infrastructure.
Technical Specifications
| Part Number | 2MLR-CPUH/S-CC |
| Manufacturer | Honeywell Process Solutions |
| Series / Platform | FSC – Fail Safe Controller |
| Module Type | High Speed CPU / Safety CPU Module |
| Architecture | Triple Modular Redundancy (TMR) compatible |
| Safety Integrity Level | SIL 2 / SIL 3 capable |
| Communication | CC (Control Communication) backplane interface |
| Certification | IEC 61508, IEC 61511 |
| HS Code | 853710 |
| Condition | New / Surplus / Refurbished (specify on inquiry) |
Why Engineers Specify This Model
- High-Speed Execution: The CPUH/S variant delivers faster scan cycle performance versus standard FSC CPUs, critical for fast-acting ESD and HIPPS applications where response time is a safety parameter.
- Proven FSC Platform: Honeywell FSC is one of the most widely deployed safety PLCs globally, with decades of field validation in SIL 3 environments.
- TMR Fault Tolerance: Supports triple redundant configurations, enabling 2oo3 voting logic for continuous availability without spurious trips.
- Seamless Integration: Native compatibility with Honeywell FSC I/O modules, FSC Manager engineering software, and Experion PKS DCS integration.
- Long Service Life: Designed for 10–20 year operational lifecycles typical of process plant safety systems.
Complete System Bill of Materials
The 2MLR-CPUH/S-CC is typically deployed alongside the following FSC components. Contact Konmask for complete system sourcing:
- FSC Power Supply Modules (e.g., 2MLR-PS)
- FSC Digital Input / Output Modules
- FSC Analog Input / Output Modules
- FSC Communication Modules (Profibus, Modbus, Ethernet)
- FSC Chassis / Rack (2MLR series)
- FSC Manager Engineering Workstation Software
- Honeywell Experion PKS Integration Gateway (optional)
Compliance & Industry Standards
- IEC 61508 – Functional Safety of E/E/PE Safety-related Systems
- IEC 61511 – Functional Safety for the Process Industry Sector
- NFPA 72 / NFPA 85 – Applicable BMS deployments
- API 670 / API 14C – Machinery and wellhead protection applications
- CE Marking – EU machinery and low voltage directive compliance
Quality Assurance & Sourcing
Konmask.com specializes in industrial automation components for mission-critical applications. Every unit offered is:
- Inspected and tested prior to shipment
- Sourced from authorized distributors or verified surplus channels
- Shipped with original packaging where available
- Supported by documentation including datasheets and certificates on request
- Backed by our quality guarantee and post-sale technical support
How to Source This Part
To request a quote or check live stock for the Honeywell 2MLR-CPUH/S-CC:
- 📧 Email: support@konmask.com
- 📞 Phone / WhatsApp: +0086 19859288691
- 🌐 Web: https://Konmask.com
Lead time, condition (new / surplus / refurbished), and quantity pricing available on request. Expedited shipping to global destinations supported.
Application-Specific FAQ
Q: Is the 2MLR-CPUH/S-CC compatible with all FSC chassis?
A: It is designed for the 2MLR series FSC rack. Confirm chassis revision compatibility with your system integrator or contact Konmask for cross-reference support.
Q: Can this CPU be used in a TMR (Triple Modular Redundant) configuration?
A: Yes. The FSC platform supports TMR architecture. Three CPU modules operate in parallel with 2oo3 voting for maximum fault tolerance in SIL 3 applications.
Q: What is the difference between CPUH and CPUH/S?
A: The /S suffix denotes the High Speed variant, offering faster logic execution cycles — critical for applications with tight process safety time (PST) requirements such as HIPPS.
Q: Do you supply the FSC Manager software license?
A: We can assist with hardware sourcing. Software licensing is managed through Honeywell’s official channels. Contact us and we will advise accordingly.
Q: What warranty applies to this module?
A: Warranty terms depend on unit condition (new vs. surplus). Contact Konmask for specific warranty documentation prior to purchase.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691