Power Protection Solution — GE UR RHH | Universal Relay Series
The GE UR RHH Universal Relay Digital I/O Module is a high-density input/output expansion card engineered for GE’s UR-series protection relay platform. Designed for mission-critical power system environments, this module extends the relay’s I/O capacity to support complex protection schemes, interlocking logic, and SCADA-driven automation across transmission and distribution networks.
Where This Product Is Used
The UR RHH module is deployed wherever engineers require reliable, high-count digital I/O within a UR-series relay chassis:
- Substation Automation: Expanding relay I/O for bay-level control, breaker status monitoring, and trip/close command execution in 110 kV–500 kV substations.
- Feeder Protection Panels: Adding discrete inputs for external protection signals (e.g., SOTF, arc flash detection) and outputs for lockout relay (86) coil drives.
- Transformer Differential Protection: Providing additional binary inputs for Buchholz relay, winding temperature, and pressure relief device contacts.
- Generator Protection Systems: Interfacing with AVR, governor, and excitation system discrete signals requiring expanded I/O beyond the base relay card set.
- Industrial Power Distribution: Cement plants, steel mills, petrochemical facilities, and mining operations using GE UR-series relays for motor and feeder protection.
- SCADA & EMS Integration: Providing hardwired status and control points to RTUs and DCS systems where IEC 61850 GOOSE messaging is supplemented by physical I/O.
Technical Specifications
- Model: UR RHH
- Series: GE Universal Relay (UR) Platform
- Module Type: Digital I/O Expansion Card
- Form Factor: UR-series plug-in module (horizontal card)
- Digital Inputs: High-density opto-isolated contact inputs
- Digital Outputs: Form-A / Form-C relay output contacts
- Input Voltage Range: Compatible with 24 VDC – 250 VDC / 120 VAC – 240 VAC wet contact inputs (per UR platform standard)
- Output Contact Rating: 8 A continuous / 30 A make (resistive), per IEC 60255
- Operating Temperature: –40°C to +85°C
- Weight: 268 g
- Compatibility: GE UR-series relay chassis (T35, T60, L90, D60, C60, F60, G60, M60, B30, etc.)
- Communication: Integrated via UR backplane bus — no external wiring required between modules
- Standards Compliance: IEC 60255, IEEE C37.90, UL 508, CE Marking
Why Engineers Specify This Model
- Platform Scalability: The UR RHH slots directly into the UR chassis backplane, enabling I/O expansion without additional external marshalling panels or terminal blocks — reducing panel footprint and wiring complexity.
- High Contact Density: Maximizes the number of protection and control signals per chassis slot, critical in space-constrained relay panels.
- Proven Field Reliability: GE UR-series modules are installed in thousands of substations globally, with a documented MTBF exceeding 200,000 hours under continuous service conditions.
- Seamless Firmware Integration: I/O points are natively mapped in UR’s EnerVista configuration software — no third-party driver or mapping table required.
- Backward Compatibility: Interoperable with legacy UR chassis firmware versions, protecting existing capital investment during relay upgrades or panel refurbishments.
- Reduced Commissioning Time: Plug-and-play module recognition by the UR CPU card eliminates manual I/O address configuration at the hardware level.
Complete System Bill of Materials
For a complete UR-series protection relay system, engineers typically specify the following alongside the UR RHH module:
- GE UR CPU Module (e.g., 9G-UR-CPU-A or equivalent per relay model)
- GE UR Power Supply Module (24/48/125/250 VDC input variants)
- GE UR AC/DC Analog Input Module (for CT/VT signal acquisition)
- GE UR Communications Module (IEC 61850, DNP3, Modbus — e.g., 9G-UR-COM-A)
- GE UR Chassis (4-slot, 8-slot, or 12-slot horizontal/vertical)
- GE EnerVista UR Setup Software (for configuration and commissioning)
- Panel-mount relay test plug (Omicron CMC or equivalent for FAT/SAT)
Contact support@konmask.com for a complete BOM quotation tailored to your protection scheme.
Compliance & Industry Standards
- IEC 60255: Measuring relays and protection equipment
- IEEE C37.90: Relays and relay systems associated with electric power apparatus
- IEC 61850: Communication networks and systems for power utility automation (platform-level)
- UL 508: Industrial control equipment
- CE Marking: Conformity with EU Low Voltage Directive and EMC Directive
- RoHS Compliant: Restriction of Hazardous Substances Directive 2011/65/EU
- NERC CIP: Compatible with cyber-secure substation architectures when deployed within compliant UR relay systems
Quality Assurance & Sourcing
Konmask.com sources GE UR-series modules through verified industrial automation supply channels. Every unit offered is:
- Inspected for physical integrity, connector condition, and label authenticity prior to listing
- Tested for basic functional continuity where test equipment permits
- Stored in ESD-safe, climate-controlled warehouse conditions
- Shipped with anti-static packaging and shock-absorbing outer cartons
- Traceable to documented procurement records available upon request for regulated utility procurement processes
We supply both new surplus and refurbished/tested units. Condition is clearly stated on each listing. Refurbished units carry a 90-day functional warranty.
How to Source This Part
- Confirm Compatibility: Verify your UR chassis model and firmware version against GE’s UR module compatibility matrix (available in the UR Installation Manual, GEK-113000 series).
- Request a Quote: Email support@konmask.com with your chassis model, required quantity, and delivery timeline. We respond within 1 business day.
- Place Order: Add to cart directly on Konmask.com, or request a formal proforma invoice for utility/corporate procurement workflows.
- Expedited Shipping: DHL Express, FedEx International Priority, and sea freight options available. Export documentation (commercial invoice, packing list, COO) provided for all international shipments.
- Technical Support: Post-delivery configuration questions answered by our automation engineering team at no additional charge.
Application-Specific FAQ
Q: Is the UR RHH compatible with all GE UR relay models?
A: The RHH module is designed for the GE UR platform and is compatible with most UR-series relay chassis. Compatibility depends on chassis slot type and firmware version. Contact us with your specific relay model for confirmation before ordering.
Q: Can this module be used as a standalone I/O unit?
A: No. The UR RHH is a plug-in expansion module that requires a GE UR relay chassis and CPU module to operate. It communicates via the UR backplane bus and cannot function independently.
Q: What is the lead time for this module?
A: In-stock units ship within 1–3 business days. For large quantities or specific firmware/hardware revisions, lead time is typically 5–10 business days. Contact us for current stock status.
Q: Do you provide GE EnerVista configuration support?
A: Yes. Our engineering team can assist with I/O mapping, FlexLogic configuration, and settings file review for UR-series relays. Contact support@konmask.com to discuss your project requirements.
Q: Is export to my country permitted?
A: GE UR-series relay modules are subject to export control regulations (EAR/ECCN classification). Konmask.com complies with all applicable export laws. We will confirm export eligibility for your destination country prior to shipment.
Q: Can you supply a Certificate of Conformance (CoC) or test report?
A: Yes, for new surplus units we provide manufacturer CoC where available. For refurbished units, we provide our internal inspection and test report. Requests must be made at time of order.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691


