Siemens 6GK1415-2AA10 DP/AS-Interface Link | Replacement, Equivalent & Selection Guide
The Siemens 6GK1415-2AA10 is a SIMATIC NET DP/AS-Interface Link that bridges PROFIBUS DP master systems with AS-Interface (AS-i) slave networks. Designed for procurement engineers and system integrators, this page provides a comprehensive selection guide, compatible replacements, and sourcing verification for the 6GK1415-2AA10.
Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | 6GK1415-2AA10 |
| Manufacturer | Siemens AG |
| Product Family | SIMATIC NET AS-Interface |
| Function | DP/AS-Interface Link Gateway |
| Upper Interface | PROFIBUS DP (Slave) |
| Lower Interface | AS-Interface (AS-i) Master |
| AS-i Slaves Supported | Up to 31 standard / 62 A/B slaves |
| PROFIBUS DP Baud Rate | 9.6 kbps – 12 Mbps (auto-detect) |
| AS-i Cycle Time | ≤ 5 ms (31 slaves) |
| Supply Voltage | AS-i bus powered (29.5–31.6 V DC) |
| Protection Class | IP20 |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | -40 °C to +85 °C |
| Weight | 196 g |
| Mounting | DIN rail (35 mm) |
| Dimensions (W×H×D) | Approx. 45 × 110 × 75 mm |
| Certifications | CE, UL, ATEX (Zone 2) |
| Country of Origin | Germany |
Compatible Replacement & Equivalent Models
When the 6GK1415-2AA10 is discontinued or unavailable, the following Siemens models are the primary upgrade paths and functional equivalents:
| Model | Description | Compatibility Notes |
|---|---|---|
| 6GK1415-2AA01 | DP/AS-i Link Advanced (predecessor) | Direct functional predecessor; same wiring footprint |
| 6GK1415-2BA10 | DP/AS-i Link 20E | Extended I/O mapping; recommended upgrade for new designs |
| 6GK1415-2BA00 | DP/AS-i Link 20E (earlier firmware) | Compatible with same AS-i topology |
| 3RK1400-1BQ00-0AA3 | AS-i Master CM 1243-2 (S7-1200) | For migration to TIA Portal / S7-1200 platforms |
| Pepperl+Fuchs VBG-PB-K20-D | Third-party DP/AS-i gateway | Cross-brand alternative; verify I/O mapping before use |
Note: Always verify GSD file compatibility and firmware version before substituting modules in live systems.
Why Choose the Original Model
- Proven SIMATIC NET ecosystem integration — native GSD file support for STEP 7 and TIA Portal
- Deterministic AS-i cycle time — ≤ 5 ms ensures reliable sensor/actuator response in safety-critical lines
- Transparent data mapping — direct bit-level I/O mapping between PROFIBUS DP and AS-i slaves without additional configuration
- Wide baud rate auto-detection — 9.6 kbps to 12 Mbps eliminates manual PROFIBUS speed configuration
- AS-i bus powered — no separate 24 V DC supply required, simplifying cabinet wiring
- ATEX Zone 2 rated — suitable for light hazardous area installations
Typical Applications
- Automotive body shop conveyor and transfer line control
- Packaging machinery with distributed sensor/actuator networks
- Food & beverage bottling lines requiring IP20 cabinet-mounted gateways
- Pharmaceutical process equipment with PROFIBUS DP PLCs and AS-i field devices
- Material handling systems: sorters, palletizers, and AGV charging stations
- Building automation and HVAC control panels integrating AS-i sensors
System Compatibility
| Platform | Compatibility | Configuration Tool |
|---|---|---|
| Siemens S7-300 / S7-400 | ✅ Full | STEP 7 v5.x + GSD file |
| Siemens S7-1500 (PROFIBUS DP) | ✅ Full | TIA Portal v13+ |
| Siemens S7-1200 (CM 1243-5) | ✅ Full | TIA Portal v13+ |
| Third-party PROFIBUS DP Masters | ⚠️ Partial | Standard GSD file (import required) |
| PROFINET controllers | ❌ Not direct | Requires PN/DP coupler (e.g. 6GK1411-5AB00) |
| AS-i Specification 2.1 slaves | ✅ Full | Native |
| AS-i Safety slaves | ❌ Not supported | Use 6GK1415-2BA10 or dedicated safety gateway |
Selection Guide
Use the decision matrix below to confirm the 6GK1415-2AA10 is the right module for your application:
| Requirement | 6GK1415-2AA10 | 6GK1415-2BA10 (Upgrade) |
|---|---|---|
| Upper network: PROFIBUS DP | ✅ | ✅ |
| Lower network: AS-Interface | ✅ | ✅ |
| AS-i Safety slaves required | ❌ | ✅ |
| Extended I/O data (>4 bit/slave) | ❌ | ✅ |
| Standard 31/62 slave topology | ✅ | ✅ |
| Bus-powered (no 24 V DC) | ✅ | ✅ |
| ATEX Zone 2 | ✅ | ✅ |
| TIA Portal native support | ✅ (GSD) | ✅ (native) |
| Legacy STEP 7 project | ✅ Best fit | ⚠️ Requires re-config |
Recommendation: For new designs or safety-critical AS-i networks, upgrade to the 6GK1415-2BA10. For direct replacement in existing STEP 7 projects, the 6GK1415-2AA10 remains the preferred choice.
Quality Assurance & Sourcing
- Authorized supply chain — Konmask.com sources 6GK1415-2AA10 units from verified Siemens distributors and factory-sealed stock
- Counterfeit screening — every unit undergoes label verification, date code inspection, and functional power-on test before shipment
- Traceability — batch records and supplier documentation available on request for MRO and OEM procurement teams
- Packaging integrity — ESD-safe anti-static bags with original Siemens carton where available
- Warranty — 12-month replacement warranty against manufacturing defects
How to Order
- Confirm part number: 6GK1415-2AA10 (Siemens MLFB)
- Specify quantity and required delivery timeline
- Submit RFQ via support@konmask.com or add to cart directly
- Receive quotation with lead time, COO documentation, and test report within 24 hours
- Payment: T/T, PayPal, or trade credit (approved accounts)
Replacement & Compatibility FAQ
Q: Can the 6GK1415-2AA10 replace the 6GK1415-2AA01 directly?
A: Yes. The 6GK1415-2AA10 is the successor to the 6GK1415-2AA01 with the same wiring and GSD file structure. No hardware modification is required.
Q: Is the 6GK1415-2AA10 compatible with PROFINET?
A: No. It operates as a PROFIBUS DP slave on the upper interface. For PROFINET integration, a PN/DP coupler (e.g., 6GK1411-5AB00) is required upstream.
Q: Can I use third-party AS-i slaves with this gateway?
A: Yes, provided the slaves comply with AS-i Specification 2.1. Siemens-specific extended addressing features may not be available for non-Siemens slaves.
Q: What is the maximum number of AS-i slaves supported?
A: Up to 31 standard slaves or 62 slaves using A/B addressing (AS-i Spec 2.1 extended addressing).
Q: Does Konmask.com provide the GSD file for this module?
A: Yes. The GSD file (SI008F10.GSD) is available for download upon order confirmation, or contact support@konmask.com.
Q: What is the lead time for the 6GK1415-2AA10?
A: In-stock units ship within 3–5 business days. For large quantities or special requirements, contact us for a dedicated lead time assessment.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691