W&T 58631 Communication Server – Serial to Ethernet Gateway | Com-Server Family
Engineering Background: Industrial automation networks increasingly demand seamless integration between legacy serial devices and modern Ethernet/IP infrastructure. The W&T 58631 bridges this gap as a high-performance serial-to-Ethernet gateway engineered by Wiesemann & Theis (W&T), a German manufacturer with over 40 years of industrial connectivity expertise.
Product Positioning: The 58631 is purpose-built for procurement engineers and system integrators who need a reliable, DIN-rail-mountable communication server to connect RS-232/RS-422/RS-485 serial devices to TCP/IP networks without modifying existing field equipment. It is a core component of W&T’s Com-Server family, trusted in SCADA, PLC, and building automation environments worldwide.
Complete Technical Specifications
- Part Number / SKU: 58631
- Manufacturer: Wiesemann & Theis (W&T), Germany
- Product Family: Com-Server
- Function: Serial-to-Ethernet Communication Server
- Serial Interface: RS-232 / RS-422 / RS-485 (software-selectable)
- Network Interface: 10/100 Mbit/s Ethernet (RJ-45)
- Protocols: TCP/IP, UDP, Telnet, DHCP, DNS, HTTP, SNMP
- Baud Rate: 300 – 115,200 bps
- Data Bits: 7 or 8
- Parity: None / Even / Odd
- Stop Bits: 1 or 2
- Operating Voltage: 24 VDC (±20%)
- Power Consumption: ≤ 3 W
- Operating Temperature: 0 °C to +55 °C
- Storage Temperature: -20 °C to +70 °C
- Mounting: DIN rail (35 mm)
- Housing: Compact plastic enclosure
- Weight: approx. 3,600 g (packaged)
- Certifications: CE, RoHS
- Country of Origin: Germany
Proven Application Environments
- SCADA & HMI integration – connect legacy serial PLCs to Ethernet-based supervisory systems
- Building automation – link BACnet MS/TP or Modbus RTU devices to IP networks
- Industrial process control – transparent serial tunneling across TCP/IP infrastructure
- Remote device management – access serial consoles of routers, switches, and UPS units via network
- Energy management – integrate smart meters and power analyzers with RS-485 output
- Machine tool & CNC – bridge RS-232 CNC controllers to plant-level Ethernet
Engineering Advantages
- Transparent Serial Tunneling: Operates in Raw TCP mode for zero-protocol-overhead data pass-through, preserving existing serial application logic
- Multi-Protocol Support: Native TCP/IP, UDP, and Telnet modes selectable per application requirement
- Web-Based Configuration: Integrated HTTP server enables parameter setup without proprietary software
- DHCP & Static IP: Flexible network addressing for both managed and unmanaged LAN environments
- DIN Rail Form Factor: Compact footprint integrates directly into standard control cabinets
- Industrial-Grade Reliability: Designed for 24/7 continuous operation in harsh industrial environments
- German Engineering: Manufactured and quality-controlled in Germany to IEC industrial standards
System Architecture & Signal Flow
The W&T 58631 operates as a transparent protocol converter. Serial data from field devices (RS-232/422/485) is encapsulated into TCP/IP or UDP packets and transmitted across the Ethernet backbone to host systems, SCADA servers, or peer devices. The reverse path is equally transparent. Configuration is performed via the embedded web server (HTTP) or via W&T’s WuTility network management tool. The device supports both client and server TCP modes, enabling flexible point-to-point and point-to-multipoint topologies.
Sourcing & Quality Verification
- All units sourced through authorized W&T distribution channels or verified OEM surplus
- Each unit inspected for physical integrity, label authenticity, and firmware version prior to shipment
- Original manufacturer packaging and documentation preserved where available
- Traceability records maintained for B2B procurement compliance
- Counterfeit-risk assessment performed on all non-new stock
Procurement Process
- Step 1: Submit RFQ via support@konmask.com or WhatsApp +0086 19859288691
- Step 2: Receive quote with lead time, stock status, and shipping options within 24 hours
- Step 3: Confirm order with PO or proforma invoice
- Step 4: Payment via T/T, PayPal, or other agreed method
- Step 5: Dispatch with tracking number; DHL / FedEx / UPS express available
- Step 6: Post-delivery technical support and documentation provided on request
Technical FAQ
Q: Can the 58631 handle RS-485 multi-drop networks?
A: Yes. The RS-485 interface supports multi-drop bus topologies with up to 32 nodes at baud rates up to 115,200 bps.
Q: Is the device compatible with Modbus TCP?
A: The 58631 provides transparent serial tunneling; Modbus RTU frames are encapsulated in TCP, making it compatible with Modbus TCP gateways and SCADA drivers that support this mode.
Q: What configuration software is required?
A: No proprietary software is required. Configuration is accessible via any web browser through the built-in HTTP server. W&T’s free WuTility tool is optionally available for network-wide device discovery.
Q: Is the unit suitable for 24/7 industrial operation?
A: Yes. The 58631 is rated for continuous operation at 0–55 °C with no scheduled maintenance intervals.
Q: Can I get a datasheet or CE declaration?
A: Yes. Contact support@konmask.com and we will provide the official W&T datasheet, CE declaration, and wiring diagrams.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691