Allen-Bradley 1492-CABLE025TBCH Digital Cable | Replacement, Equivalent & Selection Guide
The Allen-Bradley 1492-CABLE025TBCH is a 0.25-meter pre-wired digital cable designed for use with Rockwell Automation 1492 interface modules. It provides a reliable, plug-and-play wiring solution between PLC I/O modules and terminal blocks, eliminating field wiring errors and reducing installation time in industrial control panels.
At Konmask.com, we supply genuine and compatible 1492-CABLE025TBCH cables for MRO, system integration, and OEM applications — with fast global shipping and expert pre-sales support.
Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | 1492-CABLE025TBCH |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Series | 1492 Interface Module Cable |
| Cable Length | 0.25 m (25 cm) |
| Cable Type | Pre-wired Digital I/O Cable |
| Connector Style | TBCH (Terminal Block to Cable Header) |
| Compatible I/O Modules | 1756, 1769, 1794 series digital I/O |
| Wire Gauge | 28 AWG |
| Weight | Approx. 160 g |
| Operating Temperature | 0°C to +60°C |
| Certifications | CE, UL |
Compatible Replacement & Equivalent Models
The following models are functionally compatible or serve as direct replacements for the 1492-CABLE025TBCH in specific configurations:
| Model | Length | Connector Type | Notes |
|---|---|---|---|
| 1492-CABLE025TBCH | 0.25 m | TBCH | Original model (this listing) |
| 1492-CABLE050TBCH | 0.50 m | TBCH | Longer version, same connector |
| 1492-CABLE100TBCH | 1.00 m | TBCH | Extended reach applications |
| 1492-CABLE025A | 0.25 m | Type A | Alternative connector style |
| 1492-CABLE025D | 0.25 m | Type D | For 1794 FLEX I/O modules |
Note: Always verify the connector type and I/O module series before substituting. Contact Konmask.com for cross-reference assistance.
Why Choose the Original 1492-CABLE025TBCH
- Factory-terminated precision: Pre-wired to exact Rockwell Automation specifications — no field crimping required.
- Error-free installation: Color-coded conductors and keyed connectors prevent miswiring.
- Guaranteed compatibility: Engineered specifically for 1492 interface modules and matched I/O racks.
- Reduced downtime: Plug-and-play design cuts panel wiring time by up to 70% vs. discrete wiring.
- Long-term reliability: Industrial-grade insulation rated for continuous duty in control cabinet environments.
Typical Applications
- ControlLogix 1756 digital I/O module wiring to 1492 terminal blocks
- CompactLogix 1769 I/O expansion panel wiring
- FLEX I/O 1794 module interface cabling
- Machine tool and robotics control panels
- Conveyor and material handling automation systems
- Process control and SCADA panel builds
- OEM machine builders requiring standardized wiring harnesses
System Compatibility
| PLC Platform | Compatible Modules | Interface Module |
|---|---|---|
| ControlLogix 1756 | 1756-IB16, 1756-OB16E, 1756-IA16 | 1492-IFM20F-F-2 |
| CompactLogix 1769 | 1769-IQ16, 1769-OB16P | 1492-IFM20F-F-2 |
| FLEX I/O 1794 | 1794-IB16, 1794-OB16 | 1492-IFM20F-D-2 |
| SLC 500 1746 | 1746-IB16, 1746-OB16 | 1492-IFM20F-F-2 |
Selection Guide
Use the following criteria to select the correct 1492 cable for your application:
- Step 1 — Identify your I/O module: Confirm the Rockwell Automation module series (1756 / 1769 / 1794 / 1746).
- Step 2 — Determine cable length: Measure the distance between the I/O module and the terminal block. Choose 0.25 m, 0.50 m, or 1.00 m accordingly.
- Step 3 — Confirm connector style: Match the TBCH, Type A, or Type D connector to your interface module catalog number.
- Step 4 — Check I/O point count: Verify the cable supports the required number of I/O points (16-point or 32-point variants available).
- Step 5 — Verify certifications: Ensure CE/UL compliance meets your regional installation requirements.
Still unsure? Contact our selection team with your module part number for a free cross-reference.
Quality Assurance & Sourcing
- All units sourced from authorized distributors or verified surplus channels.
- Each cable inspected for connector integrity, conductor continuity, and insulation condition prior to shipment.
- Genuine Allen-Bradley / Rockwell Automation OEM parts supplied where specified.
- Compatible third-party equivalents clearly labeled and differentiated from OEM stock.
- Traceability documentation available on request for MRO and maintenance applications.
How to Order
- Click Add to Cart or Buy Now above.
- For bulk orders (10+ units), email support@konmask.com for a volume quote.
- Specify your required quantity, delivery address, and any urgency requirements.
- We accept T/T bank transfer, PayPal, and major credit cards.
- Lead time: In-stock items ship within 1–3 business days. ETA provided at order confirmation.
Replacement & Compatibility FAQ
Q: Can I use 1492-CABLE050TBCH instead of 1492-CABLE025TBCH?
A: Yes — the 0.50 m version uses the same connector and is fully compatible. Choose based on the physical distance in your panel.
Q: Is the 1492-CABLE025TBCH compatible with 1769 CompactLogix?
A: Yes, when paired with the correct 1492 interface module for the 1769 I/O series.
Q: Do you supply genuine Rockwell Automation parts?
A: Yes. We supply both genuine OEM and verified compatible equivalents. Please specify your preference when ordering.
Q: What is the lead time for out-of-stock items?
A: Typically 2–4 weeks for factory-order items. Contact us for current availability.
Q: Can I return the cable if it doesn’t fit?
A: Yes — unused items in original packaging may be returned within 30 days. See our returns policy for details.
© 2026 Konmask.com. All rights reserved.