Allen-Bradley 1797-IRT8 RTD/Thermocouple Input Module – FLEX I/O Series
When a temperature sensor fails to communicate with your control system, the consequences cascade fast — process shutdowns, unplanned downtime, and in critical industries like oil & gas or pharmaceuticals, potential safety incidents. The Allen-Bradley 1797-IRT8 RTD Input Module is the precision interface that keeps your thermal measurement loop intact, converting raw resistance or millivolt signals from RTD and thermocouple sensors into accurate, actionable data for your Rockwell Automation control system. Without it, your FLEX I/O rack loses its eyes on temperature — and your process loses its safety net.
Within the FLEX I/O 1797 series, the 1797-IRT8 occupies a specialized niche: it is the 8-channel universal input module designed to handle both RTD (Resistance Temperature Detector) and thermocouple sensor types in a single compact form factor. This dual-input capability makes it one of the most versatile temperature acquisition modules in the Rockwell Automation portfolio, widely deployed across global process industries where multi-sensor temperature monitoring is a baseline requirement for compliance and quality control.
Technical Specifications
- Part Number: 1797-IRT8
- Series: Allen-Bradley FLEX I/O (1797 Series)
- Manufacturer: Rockwell Automation / Allen-Bradley
- Module Type: RTD / Thermocouple Input Module
- Number of Channels: 8 (individually configurable)
- Input Types Supported: RTD (Pt, Ni, Cu) and Thermocouple (J, K, E, T, R, S, B, C)
- Communication: FLEX I/O backplane interface
- Backplane Current: 75 mA @ 5V DC
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Storage Temperature: -40°C to 85°C
- Relative Humidity: 5% to 95% non-condensing
- Dimensions (H × W × D): Standard FLEX I/O single-slot module
- Certifications: UL, CE, C-Tick
- Compatible Adapters: 1797-AENTR, 1797-OBN8, and other FLEX I/O adapters
Key Features & Benefits
- Universal 8-Channel Input: Each of the 8 channels can be independently configured for RTD or thermocouple input, eliminating the need for separate modules and reducing panel space.
- High Measurement Accuracy: Precision analog-to-digital conversion ensures reliable temperature data critical for process control and regulatory compliance.
- Flexible Sensor Compatibility: Supports a wide range of industry-standard RTD and thermocouple types, making it adaptable to existing sensor infrastructure without rewiring.
- Compact FLEX I/O Form Factor: Designed for the 1797 FLEX I/O platform, enabling distributed I/O architectures that reduce wiring costs and improve system scalability.
- Open-Wire Detection: Built-in diagnostics detect open-circuit sensor faults, providing immediate alerts to prevent undetected process deviations.
- Seamless Rockwell Integration: Fully compatible with Studio 5000 / RSLogix 5000 programming environments for straightforward configuration and commissioning.
Industry & Equipment Applications
- Oil & Gas: Pipeline temperature monitoring, heat exchanger control, and wellhead automation systems.
- Pharmaceuticals & Life Sciences: Bioreactor temperature regulation, clean-in-place (CIP) systems, and FDA-compliant process validation.
- Food & Beverage: Pasteurization control, cold chain monitoring, and oven/dryer temperature management.
- Chemical Processing: Reactor temperature control, distillation column monitoring, and exothermic process safety.
- Power Generation: Turbine inlet temperature monitoring and boiler control systems.
- Water & Wastewater: Thermal treatment process control and environmental compliance monitoring.
System Integration & Compatible Parts
The 1797-IRT8 is designed to integrate seamlessly within the Allen-Bradley FLEX I/O ecosystem. Commonly paired components include:
- 1797-AENTR – FLEX I/O EtherNet/IP Adapter (dual-port)
- 1797-AENT – FLEX I/O EtherNet/IP Adapter
- 1797-TB3 – FLEX I/O Terminal Base Unit (3-wire)
- 1797-TB3S – FLEX I/O Terminal Base Unit with Spring Clamp
- 1756-L8x ControlLogix – Compatible upstream controller platform
- 1769-L3x CompactLogix – Compatible upstream controller platform
Configuration is performed via Studio 5000 Logix Designer or RSLogix 5000, with Add-On Profiles (AOPs) available for rapid deployment.
Our Quality Assurance Process
At Konmask.com, every Allen-Bradley 1797-IRT8 module we supply undergoes a rigorous multi-stage verification process before shipment:
- Authenticity Verification: Cross-referenced against Rockwell Automation authorized distributor records and physical label inspection.
- Visual Inspection: Examination for physical damage, corrosion, counterfeit indicators, and component integrity.
- Functional Testing: Where applicable, modules are bench-tested to confirm basic operational status.
- Secure Packaging: ESD-safe anti-static packaging with moisture barrier protection for international transit.
- Documentation: Certificate of conformity and traceability documentation available upon request.
How to Order
- Submit your inquiry via the Contact / RFQ form on this page with your required quantity and delivery timeline.
- Our technical sales team will respond within 24 business hours with availability, lead time, and a formal quotation.
- Upon PO confirmation, we arrange secure packaging and international freight with full tracking.
- Export documentation (commercial invoice, packing list, COO) provided for all international shipments.
For urgent requirements or large-volume orders, contact us directly at support@konmask.com or +0086 19859288691.
Why Choose Konmask.com?
- ✅ Specialized in Industrial Automation: Focused exclusively on PLC, DCS, and automation hardware — not a generalist marketplace.
- ✅ Global Sourcing Network: Access to both new and surplus Allen-Bradley inventory from verified international sources.
- ✅ Technical Expertise: Our team includes experienced automation engineers who can advise on compatibility and system integration.
- ✅ Fast Response: RFQ responses within 24 hours; expedited sourcing for critical downtime situations.
- ✅ Secure International Shipping: Experienced in export compliance and customs documentation for CN, US, EU, and APAC destinations.
- ✅ After-Sales Support: Technical assistance available post-delivery for installation and commissioning queries.
Frequently Asked Questions
Q: What is the difference between the 1797-IRT8 and the 1797-IE8?
A: The 1797-IRT8 is specifically designed for RTD and thermocouple temperature sensor inputs, while the 1797-IE8 is a general-purpose analog current/voltage input module. The 1797-IRT8 includes cold junction compensation and linearization algorithms optimized for thermal measurement.
Q: Can the 1797-IRT8 be used with a ControlLogix system?
A: Yes. When paired with a compatible FLEX I/O adapter such as the 1797-AENTR (EtherNet/IP), the 1797-IRT8 can be integrated into a ControlLogix or CompactLogix system via the EtherNet/IP network.
Q: Do you supply new or refurbished 1797-IRT8 modules?
A: We supply both new (factory-sealed) and tested surplus units depending on availability. All units are clearly identified by condition in our quotation. Please specify your preference in your RFQ.
Q: What is the lead time for the Allen-Bradley 1797-IRT8?
A: Lead time varies by stock availability. In-stock units typically ship within 3–5 business days internationally. For out-of-stock items, our sourcing team will provide an estimated lead time in the quotation.
Q: Is the 1797-IRT8 still in production by Rockwell Automation?
A: Product lifecycle status can change. Please contact us for the latest information on production status and recommended migration paths if the module has reached end-of-life.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691
{
“@context”: “https://schema.org”,
“@graph”: [
{
“@type”: “Product”,
“name”: “Allen-Bradley 1797-IRT8 RTD Input Module”,
“description”: “Allen-Bradley 1797-IRT8 FLEX I/O 8-Channel RTD and Thermocouple Input Module. Compatible with ControlLogix and CompactLogix systems. Available at Konmask.com.”,
“sku”: “1797-IRT8”,
“mpn”: “1797-IRT8”,
“brand”: {
“@type”: “Brand”,
“name”: “Allen-Bradley”
},
“manufacturer”: {
“@type”: “Organization”,
“name”: “Rockwell Automation”
},
“category”: “RTD Input Module / Industrial Automation”,
“url”: “https://konmask.com/products/allen-bradley-1797-irt8-rtd-input-module-flex-io”,
“image”: “https://konmask.com/products/allen-bradley-1797-irt8-rtd-input-module-flex-io”,
“offers”: {
“@type”: “Offer”,
“url”: “https://konmask.com/products/allen-bradley-1797-irt8-rtd-input-module-flex-io”,
“priceCurrency”: “USD”,
“availability”: “https://schema.org/InStock”,
“seller”: {
“@type”: “Organization”,
“name”: “Konmask.com”
}
}
},
{
“@type”: “FAQPage”,
“mainEntity”: [
{
“@type”: “Question”,
“name”: “What is the difference between the 1797-IRT8 and the 1797-IE8?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “The 1797-IRT8 is specifically designed for RTD and thermocouple temperature sensor inputs, while the 1797-IE8 is a general-purpose analog current/voltage input module. The 1797-IRT8 includes cold junction compensation and linearization algorithms optimized for thermal measurement.”
}
},
{
“@type”: “Question”,
“name”: “Can the 1797-IRT8 be used with a ControlLogix system?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Yes. When paired with a compatible FLEX I/O adapter such as the 1797-AENTR (EtherNet/IP), the 1797-IRT8 can be integrated into a ControlLogix or CompactLogix system via the EtherNet/IP network.”
}
},
{
“@type”: “Question”,
“name”: “Do you supply new or refurbished 1797-IRT8 modules?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “We supply both new (factory-sealed) and tested surplus units depending on availability. All units are clearly identified by condition in our quotation.”
}
},
{
“@type”: “Question”,
“name”: “What is the lead time for the Allen-Bradley 1797-IRT8?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Lead time varies by stock availability. In-stock units typically ship within 3–5 business days internationally. For out-of-stock items, our sourcing team will provide an estimated lead time in the quotation.”
}
},
{
“@type”: “Question”,
“name”: “Is the 1797-IRT8 still in production by Rockwell Automation?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Product lifecycle status can change. Please contact us for the latest information on production status and recommended migration paths if the module has reached end-of-life.”
}
}
]
}
]
}