Process Measurement Solution – Endress+Hauser CYK10-A151 | Memosens Digital Measuring Cable
Where This Product Is Used
The Endress+Hauser CYK10-A151 is a Memosens digital measuring cable engineered for demanding process environments where signal integrity and sensor intelligence are critical. Typical deployment scenarios include:
- Wastewater & Water Treatment Plants – Continuous pH, ORP, and dissolved oxygen monitoring in aeration basins and effluent channels
- Chemical & Petrochemical Processing – Corrosive media measurement in reactors, neutralization tanks, and scrubbers
- Food & Beverage Production – CIP/SIP-compatible inline measurement for pH and conductivity in hygienic processes
- Pharmaceutical Manufacturing – GMP-compliant sensor connectivity with full digital traceability
- Power Generation – Cooling water chemistry monitoring in thermal and nuclear plants
- Pulp & Paper Industry – Bleaching and pH control loops requiring robust, moisture-proof connections
Technical Specifications
| Parameter | Value |
|---|---|
| Model / SKU | CYK10-A151 |
| Manufacturer | Endress+Hauser |
| Product Series | Memosens CYK10 |
| Cable Type | Digital Measuring Cable (Memosens Protocol) |
| Connection Technology | Inductive, contact-free digital signal transmission |
| Compatible Sensors | All Endress+Hauser Memosens-enabled pH, ORP, conductivity, DO sensors |
| Cable Length | Per A151 variant specification |
| Ingress Protection | IP68 (submersible-grade connector) |
| Temperature Range | –20 °C to +70 °C (cable); sensor-dependent at process end |
| Signal Transmission | Digital (no analog signal degradation over cable length) |
| Data Stored on Sensor | Calibration history, operating hours, sensor diagnostics |
| Weight | ~1,000 g (varies by length) |
Why Engineers Specify This Model
- Zero Signal Degradation – Memosens digital protocol transmits fully digitized sensor data, eliminating noise and drift caused by long analog cable runs
- Hot-Swap Capability – Sensors can be disconnected and reconnected under live process conditions without measurement interruption
- Predictive Maintenance Ready – Sensor intelligence (calibration data, glass impedance, operating hours) is stored on the sensor chip and readable via the cable
- Moisture-Proof Inductive Coupling – Contact-free connection eliminates corrosion failures at the cable/sensor junction, a common failure point in wet environments
- Plug-and-Play Calibration – Sensors can be pre-calibrated in the lab and swapped in the field without reconfiguration
- Broad Transmitter Compatibility – Works with Liquiline CM44x, Mycom CPM153, and other E+H Memosens-compatible transmitters
Complete System Bill of Materials
For a complete Memosens measurement loop, engineers typically specify:
- Memosens Sensor (e.g., Orbisint CPS11D for pH, Oxymax COS61D for DO)
- CYK10-A151 Digital Measuring Cable ← This product
- Memosens-compatible Transmitter (e.g., Liquiline CM444, Mycom CPM153)
- Retractable / Immersion Assembly (e.g., Cleanfit CPA471, Flexdip CYA112)
- Junction Box / Cable Gland (for panel or field-mount installations)
Compliance & Industry Standards
- Memosens Protocol – Endress+Hauser proprietary digital standard (IEC 61158 compatible ecosystem)
- IP68 ingress protection per IEC 60529
- CE Marking – EMC Directive 2014/30/EU compliant
- RoHS compliant materials
- Suitable for use in ATEX / IECEx Zone 1 & Zone 2 classified areas (verify with sensor/transmitter combination documentation)
- FDA-compatible materials for food-contact adjacent applications (verify with E+H datasheet)
Quality Assurance & Sourcing
Konmask.com sources the CYK10-A151 through verified industrial automation supply channels. Every unit is:
- Inspected for physical integrity and connector condition prior to dispatch
- Shipped with original manufacturer packaging where available
- Traceable to batch documentation upon request
- Backed by Konmask’s sourcing guarantee for genuine Endress+Hauser components
How to Source This Part
To place an order or request a quotation for the Endress+Hauser CYK10-A151:
- Online: Add to cart directly on this page
- Email RFQ: [email protected] – include quantity, delivery location, and required lead time
- Phone / WhatsApp: +0086 19859288691
- Bulk / Project Orders: Contact us for volume pricing and project-specific lead time commitments
Application-Specific FAQ
Q: Is the CYK10-A151 compatible with third-party Memosens sensors?
A: The CYK10 series is designed for Endress+Hauser Memosens sensors. Third-party compatibility depends on whether the sensor implements the full Memosens protocol stack — consult your sensor manufacturer.
Q: Can this cable be used in submerged applications?
A: Yes. The IP68-rated connector is designed for continuous submersion. Verify the immersion depth rating against your specific installation requirements.
Q: What transmitters are compatible with the CYK10-A151?
A: All Endress+Hauser Memosens-compatible transmitters including Liquiline CM44x series, Mycom CPM153, and Smartec CTM10 are compatible.
Q: Does the cable store calibration data?
A: No — calibration data is stored on the sensor chip itself. The CYK10-A151 cable serves as the digital communication link that reads and transmits this data to the transmitter.
Q: What is the lead time for CYK10-A151?
A: Standard lead time is 3–7 business days for in-stock units. Contact us for urgent or project-volume requirements.