The E-T-A 2210-S211-P1F2-H111-4A is a single-pole thermal circuit breaker from E-T-A’s 2210 series, designed for equipment protection in industrial control panels, power distribution systems, and automation enclosures. This page provides full technical specifications, compatible replacement models, application guidance, and a selection guide to help engineers and procurement teams make the right choice.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | E-T-A (Elektro-Thermische Apparate GmbH) |
| Part Number / SKU | 2210-S211-P1F2-H111-4A |
| Series | 2210 |
| Type | Thermal Circuit Breaker (Single-Pole) |
| Rated Current | 4 A |
| Voltage Rating | Up to 250 V AC / 65 V DC |
| Trip Mechanism | Thermal (bimetallic) |
| Mounting Style | Panel Mount |
| Actuator Type | Push-button (manual reset) |
| Contact Configuration | 1-pole |
| Operating Temperature | -25°C to +85°C |
| Weight | ~300 g (packaged) |
| Approvals | UL, CSA, VDE (series-level) |
Compatible Replacement & Equivalent Models
The following models are commonly evaluated as replacements or equivalents for the ETA 2210-S211-P1F2-H111-4A. Always verify electrical ratings, mounting dimensions, and trip characteristics before substitution:
- E-T-A 2210-S211-P1F2-H111-2A — Same series, 2 A rated current variant
- E-T-A 2210-S211-P1F2-H111-6A — Same series, 6 A rated current variant
- E-T-A 2210-S211-P1F2-H111-8A — Same series, 8 A rated current variant
- E-T-A 3120-F311-P7T1-W01Q-4A — Alternative E-T-A series with similar thermal protection
- Carling Technologies CMB1-B-24-630-2B1-C — Cross-brand equivalent, verify pin-out and trip curve
- Airpax IELH111-1-62-4.0A — Functional equivalent for panel-mount applications
- Schurter 4430.0052 — European equivalent, confirm mounting footprint
⚠ Disclaimer: Replacement suitability depends on your specific application. Consult your system engineer or contact Konmask.com for verified cross-reference support.
Why Choose the Original Model
- Exact trip curve compliance — OEM-specified thermal response ensures system protection as designed
- Certified approvals — UL/CSA/VDE certifications maintained for regulatory compliance
- Drop-in fit — No panel modification required; preserves existing wiring and mounting
- Long-term availability — Sourced from authorized channels with traceability documentation
- Warranty integrity — Using original parts preserves equipment manufacturer warranty
Typical Applications
- Industrial control panels and MCC (Motor Control Centers)
- Power distribution boards and sub-panels
- Automation enclosures (PLC, DCS, SCADA systems)
- Test & measurement equipment protection
- Medical device power supply protection
- Telecommunications and data center power rails
- Marine and transportation control systems
System Compatibility
The 2210-S211-P1F2-H111-4A is compatible with standard 22 mm panel cutout configurations. It integrates with:
- Siemens SIMATIC S7 / S5 control panel assemblies
- Allen-Bradley / Rockwell Automation PLC enclosures
- Schneider Electric Modicon-based control cabinets
- Beckhoff, Mitsubishi, Omron, and Keyence automation systems
- Custom OEM industrial equipment requiring IEC/UL-rated branch circuit protection
Selection Guide
Use the following criteria to confirm this model is correct for your application:
- Step 1 — Rated Current: Confirm load current ≤ 4 A continuous. For higher loads, select the 6 A or 8 A variant.
- Step 2 — Voltage: Verify supply voltage ≤ 250 V AC or ≤ 65 V DC.
- Step 3 — Poles: Single-pole (1P) — suitable for single-phase branch protection.
- Step 4 — Mounting: Confirm panel cutout dimensions match 2210 series datasheet (22 mm standard).
- Step 5 — Reset Type: Manual push-button reset — suitable for applications requiring operator intervention after trip.
- Step 6 — Environment: Rated for -25°C to +85°C; confirm ambient temperature of installation.
- Step 7 — Certifications: Verify required approvals (UL, CSA, VDE) match your regional compliance requirements.
Not sure? Contact our selection team with your application details for a verified recommendation.
Quality Assurance & Sourcing
- ✅ Sourced from authorized distributors and verified supply chains
- ✅ Each unit inspected for physical integrity and part number accuracy
- ✅ Traceability documentation available upon request (CoC, test reports)
- ✅ Anti-counterfeit measures: holographic labels, OEM packaging verification
- ✅ RoHS-compliant stock available — specify at time of order
How to Order
- Click Add to Cart or Buy Now above to place an order online.
- For bulk orders (>10 units), request a volume quote via support@konmask.com.
- Need a specific lead time or expedited shipping? Contact us with your PO requirements.
- International orders: DDP (Delivered Duty Paid) terms available for select regions.
📞 +0086 19859288691 | ✉ support@konmask.com
Replacement & Compatibility FAQ
Q: Can I replace the 2210-S211-P1F2-H111-4A with a 4 A breaker from another brand?
A: Functionally possible, but you must verify trip curve class (B/C/D), mounting dimensions, terminal type, and certifications. Contact us for a verified cross-reference.
Q: What does each segment of the part number mean?
A: 2210 = series; S211 = single-pole, standard terminal; P1F2 = panel-mount, push-button actuator; H111 = housing/color code; 4A = 4 amp rating.
Q: Is this part RoHS compliant?
A: E-T-A 2210 series is available in RoHS-compliant versions. Confirm with your order if compliance documentation is required.
Q: What is the lead time for this part?
A: In-stock items ship within 1–3 business days. Out-of-stock items typically have a 2–6 week lead time. Contact us for real-time availability.
Q: Do you provide a Certificate of Conformance (CoC)?
A: Yes. CoC and test reports are available upon request for all orders.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691