GE 469-P5-HI-A20-E-H – Advanced Motor Management Relay | Multilin 469 Series
Engineering Background
The GE Multilin 469 series represents General Electric’s flagship solution for comprehensive motor protection and management in industrial environments. Designed for medium-to-large induction motors, the 469 platform integrates thermal modeling, current-based protection, and advanced diagnostics into a single DIN-rail or panel-mount unit. The 469-P5-HI-A20-E-H variant is configured with high-current CT inputs, analog I/O expansion, Ethernet communications, and a high-visibility display — making it the preferred choice for critical motor assets in process industries.
Product Positioning
This relay is engineered for procurement engineers and system integrators who require a proven, IEC/ANSI-compliant motor protection device with full SCADA integration capability. It replaces legacy electromechanical overload relays and standalone protection devices with a single, intelligent unit that reduces panel footprint, wiring complexity, and commissioning time.
Complete Technical Specifications
- Model: 469-P5-HI-A20-E-H
- Manufacturer: General Electric (GE Multilin)
- Series: Multilin 469 Motor Management Relay
- CT Input Range (HI): 1–12 A (high-current input, suitable for 1 A or 5 A secondary CTs)
- Auxiliary Power Supply: 20–60 V DC / 20–48 V AC (A20 designation)
- Communications: Ethernet (E designation) — Modbus TCP/IP, DNP3 over TCP
- Display: High-visibility backlit LCD (H designation)
- Analog I/O: Expanded analog I/O module (P5 designation)
- Protection Functions: Thermal overload (49), Overcurrent (50/51), Ground fault (50G/51G), Undercurrent (37), Phase unbalance (46), Phase reversal (47), Stall/locked rotor (48/14), Starts-per-hour (66), RTD-based thermal protection (38/49)
- RTD Inputs: Up to 12 RTD inputs (motor winding, bearing, ambient)
- Output Relays: 5 programmable output relays
- Digital Inputs: 8 optically isolated digital inputs
- Metering: 3-phase current, ground current, thermal capacity, power (kW, kVAR, kVA, PF), energy (kWh)
- Data Logging: Event recorder (last 256 events), oscillography (waveform capture)
- Mounting: Panel flush-mount, 1/2 DIN cutout
- Operating Temperature: -20°C to +60°C
- Weight: 7.36 kg
- Standards: IEC 60255, ANSI/IEEE C37.90, CE, UL, CSA
Proven Application Environments
- Oil & Gas: Compressor motors, pump drives, and wellhead motor protection in upstream and midstream facilities
- Water & Wastewater: High-duty-cycle pump motors requiring starts-per-hour limiting and thermal modeling
- Mining & Minerals: Conveyor drives, crusher motors, and mill drives subject to frequent starts and high inertia loads
- Pulp & Paper: Refiner and agitator motors with RTD winding temperature monitoring
- Power Generation: Auxiliary motor protection in thermal and hydro plants
- Chemical & Petrochemical: Hazardous-area motor feeders requiring ground fault sensitivity and SCADA integration
Engineering Advantages
- Adaptive Thermal Model: Accounts for motor heating history, ambient temperature (via RTD), and cooling curves — preventing nuisance trips while protecting against genuine overloads
- Ethernet Native: Modbus TCP/IP and DNP3 over TCP eliminate the need for serial-to-Ethernet converters, simplifying DCS/SCADA integration
- Oscillography: On-board waveform capture enables post-fault analysis without external power quality meters
- RTD Multiplexing: Up to 12 RTDs on a single relay eliminates separate temperature monitoring modules
- Reduced Panel Footprint: Consolidates overload relay, ground fault relay, temperature monitor, and power meter into one 1/2 DIN unit
- Firmware Upgradeable: Field-upgradeable firmware via EnerVista 469 Setup software
System Architecture & Signal Flow
The 469-P5-HI-A20-E-H sits at the motor feeder level within the protection hierarchy:
- Upstream: MCC bus / switchgear breaker → 469 trip output → contactor/breaker trip coil
- CT Inputs: Phase CTs (1 A or 5 A secondary, HI range) + core-balance or residual ground CT → 469 current inputs
- RTD Inputs: Motor winding RTDs (Pt100) + bearing RTDs → 469 RTD module
- Communications: 469 Ethernet port → plant LAN → DCS/SCADA (Modbus TCP or DNP3)
- Analog Outputs: 4–20 mA analog outputs → DCS analog input cards (current, thermal capacity, power)
- Digital Inputs: Motor running feedback, emergency stop, external trip → 469 digital inputs
Sourcing & Quality Verification
- All units sourced from authorized GE Multilin distributors or verified OEM surplus channels
- Each unit inspected for firmware version, hardware revision, and physical condition prior to listing
- Serial number traceability available upon request for critical applications
- Calibration certificates and factory test reports available for select stock
- Konmask.com maintains a zero-counterfeit policy — units failing authentication are rejected and not listed
Procurement Process
- Step 1: Submit inquiry via product page or email support@konmask.com with your project BOM and required delivery date
- Step 2: Receive stock confirmation, lead time, and formal quotation within 1 business day
- Step 3: Issue PO against quotation; payment via T/T, L/C, or approved credit terms
- Step 4: Unit ships with commercial invoice, packing list, and optional test report
- Step 5: Post-delivery technical support available via email or WhatsApp (+86 198 5928 8691)
Technical FAQ
Q: What is the difference between the HI and LO current input versions?
A: The HI version accepts 1–12 A CT secondary input, suitable for standard 1 A or 5 A CTs. The LO version accepts 0.1–1.2 A, used with low-ratio CTs on small motors. The 469-P5-HI-A20-E-H uses HI inputs.
Q: Is the A20 power supply compatible with 24 V DC control power?
A: Yes. The A20 auxiliary supply range is 20–60 V DC, making it fully compatible with 24 V DC and 48 V DC control power systems.
Q: Can this relay communicate with a Modbus RTU DCS?
A: The E (Ethernet) variant supports Modbus TCP/IP natively. For Modbus RTU, a Modbus TCP-to-RTU gateway is required, or specify the RS485 variant (469-P5-HI-A20-A-H) at time of order.
Q: What software is required for configuration?
A: GE EnerVista 469 Setup software (free download from GE Grid Solutions). Configuration can also be performed via the front-panel keypad and display.
Q: Is a warranty available?
A: Konmask.com offers a 12-month functional warranty on all verified units. Extended warranty and on-site commissioning support available upon request.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691