Motor Control & Industrial Automation Solution – GE CK95BE300 | CK95 Series
The GE CK95BE300 is a heavy-duty 300A IEC definite purpose contactor engineered for demanding motor control, HVAC, and industrial power switching applications. Designed to IEC 60947-4-1 standards, this contactor delivers reliable, long-service-life performance in environments where uptime is non-negotiable.
Where This Product Is Used
- Large AC Motor Starters – Direct-on-line (DOL) and star-delta starting of motors up to 160 kW / 200 HP at 400 V AC
- HVAC & Chiller Plants – Compressor and fan motor switching in commercial and industrial HVAC systems
- Pump & Compressor Control Panels – Water treatment, oil & gas, and process industry pump stations
- Power Distribution Switchgear – Bus-tie and feeder switching in MCC (Motor Control Center) lineups
- Crane & Hoist Drive Systems – Reversing and plugging duty in material handling equipment
- Mining & Heavy Industry – Conveyor drives, crushers, and mill motor control in harsh environments
- Marine & Offshore Panels – Auxiliary motor control aboard vessels and offshore platforms
Technical Specifications
| Part Number / SKU | CK95BE300 |
| Manufacturer | GE (General Electric) |
| Series | CK95 |
| Type | IEC Definite Purpose Contactor |
| Rated Current (AC-3) | 300 A |
| Motor Rating (400 V) | ~160 kW / 200 HP |
| Poles | 3-pole main + auxiliary contacts |
| Standard | IEC 60947-4-1 |
| Utilization Category | AC-3 / AC-4 |
| Coil Voltage Options | 24 V AC/DC, 110 V AC, 220 V AC, 380 V AC (specify at order) |
| Mounting | DIN rail / panel mount |
| Weight | 6.26 kg |
| Enclosure | Open type (for panel installation) |
| Operating Temperature | -25°C to +60°C |
Why Engineers Specify This Model
- High Thermal Capacity – 300 A continuous rating handles large motor inrush without derating
- IEC-Compliant Design – Direct drop-in replacement for IEC MCC panels worldwide
- GE CK95 Series Reliability – Proven contact geometry and arc-quenching chambers for extended electrical life
- Flexible Coil Voltage – Multiple coil options simplify integration into existing control voltage schemes
- Auxiliary Contact Expandability – Add-on auxiliary contact blocks for interlocking and status feedback
- Compact Footprint – Optimized for space-constrained MCC cubicles
Complete System Bill of Materials
For a complete motor starter assembly using the CK95BE300, engineers typically specify:
- GE CK95BE300 – Main contactor (this item)
- GE THLC overload relay – Thermal overload protection (select range to match motor FLA)
- GE auxiliary contact block – For control circuit interlocking
- GE surge suppressor module – Coil transient suppression (RC or varistor type)
- IEC Type 2 coordination fuses – Short-circuit protection upstream
- Control transformer – If coil voltage differs from supply voltage
Compliance & Industry Standards
- IEC 60947-4-1: Low-voltage switchgear – Electromechanical contactors and motor starters
- CE Marking – Compliant for European market deployment
- RoHS Compliant – Restriction of hazardous substances
- UL / CSA listing available on select variants (confirm at order)
Quality Assurance & Sourcing
All GE contactors supplied by Konmask.com are sourced through verified industrial distribution channels. Each unit undergoes incoming inspection including:
- Visual and dimensional verification against OEM datasheet
- Label and date-code authentication
- Coil continuity and insulation resistance check
- Original manufacturer packaging inspection
We do not supply grey-market, refurbished, or counterfeit components. Traceability documentation available on request.
How to Source This Part
- In Stock: Order directly on this page for fast dispatch
- Lead Time Orders: Contact us for volume pricing and scheduled delivery
- OEM / Project Quotations: Email support@konmask.com with your BOM for a consolidated quote
- Urgent Requirements: Call +0086 19859288691 for same-day availability confirmation
- Export & Cross-Border: We ship globally with full commercial invoice and packing list documentation
Application-Specific FAQ
Q: Can the CK95BE300 be used for reversing duty?
A: Yes, with two CK95BE300 units wired in a reversing configuration with mechanical and electrical interlocking. Consult GE application notes for wiring diagrams.
Q: What overload relay is compatible with this contactor?
A: GE THLC series thermal overload relays are designed to mount directly onto the CK95 series. Select the relay current range to match your motor’s full-load amperage.
Q: Is this contactor suitable for capacitor bank switching (AC-6b)?
A: The CK95BE300 is rated AC-3/AC-4. For capacitor switching (AC-6b), please consult GE’s derating tables or specify a dedicated capacitor contactor.
Q: What is the electrical life expectancy?
A: At AC-3 duty, GE CK95 series contactors are rated for millions of operating cycles. Actual life depends on load, switching frequency, and maintenance intervals.
Q: Can I get a datasheet or wiring diagram?
A: Yes. Contact support@konmask.com and reference part number CK95BE300 to receive the official GE technical datasheet.