Flame Detection Solution — General Electric GS9208/IR2 | GS9208 Series
Where This Product Is Used
The GE GS9208/IR2 Infrared Flame Detector is engineered for mission-critical fire and flame detection in environments where hydrocarbon-based fires pose significant risk. Typical deployment sites include:
- Oil & Gas Upstream: Wellheads, drilling platforms, and production separators where flammable gas and liquid hydrocarbons are present.
- Petrochemical & Refinery Plants: Process units, storage tank farms, loading/unloading bays, and compressor stations.
- Offshore Platforms: FPSO vessels, fixed offshore installations, and subsea control rooms requiring continuous flame surveillance.
- Power Generation: Gas turbine enclosures, boiler rooms, and fuel handling areas.
- Chemical Processing: Solvent storage, reactor areas, and distillation columns with open-flame ignition risk.
- Aviation & Military: Hangars, engine test cells, and munitions storage facilities.
- Tunnels & Parking Structures: Vehicle fire detection in enclosed infrastructure.
Technical Specifications
| Parameter | Value |
|---|---|
| Model | GS9208/IR2 |
| Manufacturer | General Electric (GE) |
| Detection Technology | Dual Infrared (IR2) Flame Detection |
| Spectral Response | Infrared (IR) wavelength bands |
| Detection Range | Up to 65 m (213 ft) for 0.1 m² n-heptane fire (typical) |
| Field of View (FOV) | 90° cone angle |
| Response Time | < 5 seconds (adjustable) |
| Supply Voltage | 18–32 V DC |
| Output Signal | 4–20 mA analog + relay outputs |
| Enclosure Rating | IP66 / IP67 |
| Operating Temperature | -55°C to +75°C (-67°F to +167°F) |
| Weight | 450 g |
| Housing Material | 316L Stainless Steel |
| Certifications | ATEX, IECEx, FM, CSA (zone/division rated) |
| Mounting | Standard 1.5″ NPT / M20 conduit entry |
Why Engineers Specify This Model
- Dual-IR Technology: The IR2 configuration uses two infrared sensors to discriminate between genuine hydrocarbon flames and false alarm sources (solar radiation, hot surfaces, arc welding), dramatically reducing nuisance trips.
- Wide Temperature Range: Rated from -55°C to +75°C, making it suitable for arctic offshore installations and high-ambient desert refineries alike.
- Robust Stainless Steel Housing: 316L SS construction resists corrosion in marine, coastal, and chemically aggressive atmospheres.
- High IP Rating: IP66/67 sealing ensures reliable operation in washdown environments and heavy rain.
- Flexible Integration: 4–20 mA output and relay contacts allow direct integration with Honeywell, Siemens, Yokogawa, and GE Mark series fire & gas controllers.
- Low Maintenance: Self-diagnostic capability with fault relay output reduces inspection overhead in remote or hazardous locations.
Complete System Bill of Materials
For a complete flame detection loop using the GS9208/IR2, engineers typically specify the following complementary components:
- Flame Detector: GE GS9208/IR2 (this unit)
- Fire & Gas Controller: GE Multilin F60 / Honeywell XLS / Siemens FDCIO223
- Junction Box: Stainless steel Ex-rated JB, IP66, with terminal blocks
- Cable: Armored, screened 2-core instrumentation cable (0.75–1.5 mm²)
- Mounting Bracket: GE universal swivel bracket (stainless, adjustable ±180°)
- Conduit Fittings: ATEX-certified Ex-e or Ex-d conduit entries, M20 or ¾” NPT
- Sounder/Beacon: Eaton Fulleon or Werma Ex-rated alarm device
- Power Supply: 24 V DC DIN-rail PSU with UPS backup (e.g., Phoenix Contact QUINT)
Compliance & Industry Standards
- ATEX Directive 2014/34/EU — Zone 1 & Zone 2 hazardous area certification
- IECEx — International electrotechnical commission explosive atmosphere standard
- FM Approved — Factory Mutual Class I, Division 1 & 2
- CSA Certified — Canadian Standards Association hazardous location approval
- EN 54-10 — European standard for flame detectors in fire detection systems
- IEC 61508 / SIL — Functional safety compliance for safety instrumented systems
- NFPA 72 — National Fire Alarm and Signaling Code (US installations)
Quality Assurance & Sourcing
Konmask.com specializes in the procurement of genuine, traceable industrial automation and safety components. Every GE GS9208/IR2 unit we supply is:
- Sourced from authorized GE distributors or verified OEM supply chains
- Inspected for physical integrity, label authenticity, and packaging condition upon receipt
- Accompanied by original manufacturer documentation where available
- Stored in ESD-safe, climate-controlled warehousing to preserve component integrity
- Traceable via batch/lot records for full supply chain auditability
We do not supply counterfeit, refurbished-as-new, or grey-market components. All units are sold with a documented sourcing trail.
How to Source This Part
To request a quotation or confirm stock availability for the GE GS9208/IR2:
- Email: support@konmask.com
- Phone / WhatsApp: +0086 19859288691
- Website: https://Konmask.com
Please include your required quantity, delivery location, and any project-specific certification requirements (e.g., ATEX zone classification, SIL level) when enquiring. Lead times vary by stock availability — contact us for current ETA.
Application-Specific FAQ
Q: Can the GS9208/IR2 detect non-hydrocarbon fires such as wood or paper?
A: The IR2 technology is optimized for hydrocarbon flame signatures. Detection of non-hydrocarbon fires (cellulosic materials) is possible but with reduced sensitivity. For mixed-risk environments, consider pairing with a UV/IR or multi-spectrum detector.
Q: Is the GS9208/IR2 suitable for outdoor installation in direct sunlight?
A: Yes. The dual-IR design includes solar radiation rejection algorithms. However, for extreme solar exposure, a sun shield accessory is recommended to prevent optical window heating.
Q: What is the recommended testing interval for this detector?
A: GE recommends functional testing every 6 months using a calibrated IR test lamp. The built-in self-test relay provides continuous loop integrity monitoring between manual tests.
Q: Can this unit be integrated with a Modbus or HART network?
A: The standard GS9208/IR2 outputs 4–20 mA and relay signals. For digital fieldbus integration, consult GE’s GS9000 series accessories or use a signal converter compatible with your DCS/SCADA platform.
Q: What is the warranty and what does it cover?
A: Konmask.com provides a standard 12-month warranty against manufacturing defects on all genuine GE components. Warranty does not cover damage from improper installation, unauthorized modification, or use outside rated specifications.