Serial Communications Solution – GE IC695CMU310 | PACSystems RX3i
Where This Product Is Used
The GE IC695CMU310 Serial Communications Module is deployed across a wide range of industrial automation environments where legacy serial protocols must coexist with modern PLC architectures. Typical application scenarios include:
- Oil & Gas Facilities – Connecting remote RTUs, flow computers, and SCADA hosts via Modbus RTU over RS-485 multidrop networks.
- Water & Wastewater Treatment Plants – Polling distributed sensors, actuators, and HMI panels using ASCII or Modbus protocols across long cable runs.
- Automotive Assembly Lines – Integrating barcode scanners, vision systems, and torque tools that communicate over RS-232 serial links.
- Power Generation & Utilities – Interfacing with protective relays, meters, and IEDs using DNP3 or proprietary serial protocols bridged through the CMU310.
- Food & Beverage Processing – Coordinating weighing systems, label printers, and batch controllers in hygienic environments requiring reliable point-to-point serial links.
- Building Automation & HVAC – Communicating with chillers, AHUs, and BMS gateways over RS-485 using Modbus RTU.
- Pharmaceutical Manufacturing – Logging data from analytical instruments and environmental monitoring devices with strict audit-trail requirements.
Technical Specifications
| Part Number | IC695CMU310 |
| Manufacturer | GE / Emerson Automation Solutions |
| Product Family | PACSystems RX3i |
| Module Type | Serial Communications Module |
| Serial Ports | 2 × isolated serial ports |
| Supported Interfaces | RS-232, RS-485 (2-wire & 4-wire) |
| Protocols | Modbus RTU, Modbus ASCII, SNP, SNPX, Serial I/O |
| Baud Rate | 300 – 115,200 bps |
| Backplane Bus | RX3i Universal Backplane (PCI-based) |
| Power Consumption | 1.1 W (backplane) |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | -40 °C to +85 °C |
| Relative Humidity | 5 – 95% non-condensing |
| Weight | 450 g (approx.) |
| Dimensions (H × W × D) | Standard RX3i single-slot form factor |
| Firmware Configurable | Yes – via Proficy Machine Edition (PME) |
Why Engineers Specify This Model
- Dual Isolated Ports – Two independently isolated serial channels eliminate ground-loop interference in electrically noisy plant environments, reducing wiring faults and unplanned downtime.
- Protocol Flexibility – Native support for Modbus RTU/ASCII, SNP, and SNPX means a single module can serve as both a Modbus master/slave and a GE-native SNP host simultaneously.
- Seamless RX3i Integration – Slots directly into any RX3i universal backplane without adapters; configured entirely within Proficy Machine Edition for unified project management.
- Long-Distance RS-485 – Supports multidrop RS-485 networks up to 1,200 m, making it ideal for distributed I/O and remote device polling across large facilities.
- Proven Field Reliability – Widely deployed in critical infrastructure since the RX3i platform launch; extensive installed base ensures long-term spare-parts availability and community support.
- Backward Compatibility – Maintains compatibility with Series 90-30 SNP/SNPX devices, protecting legacy investments during phased modernization projects.
Complete System Bill of Materials
A typical RX3i serial communications node using the IC695CMU310 requires the following components:
- IC695CMU310 – Serial Communications Module (this item)
- IC695CHS012 / IC695CHS016 – RX3i Universal Backplane (12- or 16-slot)
- IC695PSA040 / IC695PSD040 – RX3i Power Supply (AC or DC input)
- IC695CPE330 / IC695CPE400 – RX3i CPU Module
- IC695ETM001 – Ethernet Module (for SCADA/HMI connectivity)
- RS-232 / RS-485 shielded cable and terminal connectors
- Proficy Machine Edition (PME) software license for configuration
Compliance & Industry Standards
- CE Marking – Compliant with EU Low Voltage and EMC Directives
- UL Listed – UL 508 (Industrial Control Equipment)
- RoHS Compliant – Restriction of Hazardous Substances Directive 2011/65/EU
- IEC 61131-2 – Programmable Controllers: Equipment Requirements and Tests
- ATEX / IECEx – Suitable for use in associated safe-area control panels serving Zone 1/2 hazardous areas (verify with project SIL assessment)
- Modbus Protocol – Conformant with Modbus.org specification (RTU & ASCII modes)
Quality Assurance & Sourcing
At Konmask.com, every IC695CMU310 unit undergoes a structured quality verification process before dispatch:
- Visual Inspection – Board-level examination for physical damage, corrosion, and counterfeit indicators (hologram labels, PCB markings, component dates).
- Functional Power-On Test – Module is energized in an RX3i test rack; LED status and backplane communication are verified.
- Firmware Version Check – Firmware revision is documented and disclosed; downgrade/upgrade options noted where applicable.
- Serialization & Traceability – Each unit’s serial number is logged against the sales order for full traceability.
- ESD-Safe Packaging – Shipped in anti-static bags with foam cushioning inside double-wall corrugated cartons.
- 90-Day Warranty – All units carry a 90-day warranty against defects in materials and workmanship.
How to Source This Part
- Confirm Part Number – Verify IC695CMU310 against your existing rack configuration and PME project hardware catalog.
- Check Firmware Compatibility – Confirm the required firmware revision with your PME version (consult GE/Emerson release notes).
- Request a Quote – Contact us at support@konmask.com or call +0086 19859288691 for volume pricing, lead time, and availability.
- Place Order – Orders accepted via the Konmask.com storefront, email PO, or bank transfer (T/T). Export documentation available for international shipments.
- Expedited Shipping – DHL / FedEx express options available for urgent plant shutdowns or emergency replacements.
Application-Specific FAQ
Q: Can the IC695CMU310 act as a Modbus master and slave simultaneously on its two ports?
A: Yes. Each port is independently configurable; Port 1 can be set as a Modbus RTU master polling field devices while Port 2 operates as a Modbus slave responding to a SCADA host.
Q: Is the IC695CMU310 compatible with the older Series 90-30 (IC693) backplane?
A: No. The CMU310 is designed exclusively for the RX3i (IC695) universal backplane. For Series 90-30 applications, refer to the IC693CMM321 or IC693CMM311.
Q: What cable type is recommended for RS-485 multidrop wiring?
A: Belden 9842 (or equivalent) 120 Ω characteristic impedance, twisted-pair, shielded cable is recommended. Terminate with 120 Ω resistors at both ends of the bus.
Q: Can this module communicate with third-party Modbus RTU devices such as ABB drives or Schneider PLCs?
A: Yes. The IC695CMU310 implements standard Modbus RTU/ASCII, making it interoperable with any compliant third-party device regardless of manufacturer.
Q: How is the module configured – via DIP switches or software?
A: Entirely via software using Proficy Machine Edition (PME). No hardware DIP switches are required; all port parameters (baud rate, parity, protocol, timeouts) are set in the PME hardware configuration.
Q: Do you supply the module with a warranty and test report?
A: Yes. Every unit ships with a Konmask inspection checklist and carries a 90-day warranty. Test reports are available upon request for critical infrastructure projects.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691