GE IC695PBM300CA PROFIBUS Master Module | Replacement, Equivalent & Selection Guide
The GE IC695PBM300CA is a PROFIBUS DP Master Module designed for the GE PACSystems RX3i platform. It enables high-speed, deterministic communication between the RX3i controller and PROFIBUS DP slave devices — including drives, I/O blocks, sensors, and field instruments — making it a cornerstone component in industrial automation and process control architectures.
At Konmask.com, we specialize in sourcing, verifying, and supplying original and equivalent automation components for engineers and procurement teams worldwide.
Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | IC695PBM300CA |
| Manufacturer | GE (General Electric) / Emerson |
| Series | PACSystems RX3i |
| Module Type | PROFIBUS DP Master |
| Communication Protocol | PROFIBUS DP (EN 50170) |
| Max Slave Devices | 125 DP slaves |
| Baud Rate | 9.6 kbps – 12 Mbps (auto-detect) |
| Bus Interface | 9-pin D-sub (DB9) female connector |
| Backplane Interface | RX3i Universal Backplane |
| Power Consumption | Supplied via backplane |
| Weight | Approx. 400 g |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -40°C to 85°C |
| Humidity | 5% to 95% non-condensing |
| Certifications | CE, UL, cUL |
| Firmware | Configurable via Proficy Machine Edition |
Compatible Replacement & Equivalent Models
If the IC695PBM300CA is unavailable or you are evaluating alternatives, the following models offer compatible or equivalent functionality:
| Model | Manufacturer | Compatibility Notes |
|---|---|---|
| IC695PBM300 | GE / Emerson | Direct predecessor; same function, earlier firmware revision |
| IC695PBM300-CA | GE / Emerson | Alternate hyphenated part number format; identical hardware |
| IC695PBM300CB | GE / Emerson | Newer revision (CB); drop-in replacement with enhanced diagnostics |
| IC695PBM300CC | GE / Emerson | Latest revision; recommended for new designs |
| CP343-5 | Siemens | PROFIBUS DP Master for S7-300; not pin-compatible but functionally equivalent in PROFIBUS role |
| 1756-DPB | Allen-Bradley | PROFIBUS DP Master for ControlLogix; cross-platform equivalent |
Note: Cross-brand replacements require re-engineering of the control program and I/O mapping. Always verify firmware and backplane compatibility before substitution.
Why Choose the Original IC695PBM300CA
- Native RX3i Integration — Plug-and-play with PACSystems RX3i backplanes; no adapter required.
- Proficy Machine Edition Support — Full configuration, diagnostics, and firmware management via GE’s native engineering tool.
- Proven Field Reliability — Widely deployed in automotive, oil & gas, water treatment, and discrete manufacturing.
- Deterministic Communication — Guaranteed cycle-time performance critical for motion and process control.
- Revision CA Stability — The CA revision is a mature, stable release with extensive field validation.
Typical Applications
- PROFIBUS DP network master in PACSystems RX3i control systems
- Integration of variable frequency drives (VFDs) via PROFIBUS
- Remote I/O expansion using PROFIBUS DP slave blocks
- Process instrumentation networks (pressure, flow, temperature transmitters)
- Automotive assembly line control and robotics integration
- Water/wastewater SCADA and DCS hybrid architectures
- Oil & gas upstream/downstream field device communication
System Compatibility
- Controller: GE PACSystems RX3i (IC695 series)
- Backplane: IC695CHS007, IC695CHS012, IC695CHS016 (7, 12, 16-slot universal backplanes)
- Power Supply: IC695PSA040, IC695PSD040, IC695PSA140
- Engineering Software: Proficy Machine Edition 8.x and above
- PROFIBUS Slaves: Any EN 50170-compliant DP slave device
Selection Guide
Use this guide to confirm the IC695PBM300CA is the right module for your application:
| Requirement | IC695PBM300CA | IC695PBM300CB/CC | Cross-Brand Alternative |
|---|---|---|---|
| RX3i backplane required | ✅ Yes | ✅ Yes | ❌ No |
| PROFIBUS DP Master role | ✅ Yes | ✅ Yes | ✅ Yes (own platform) |
| Up to 125 DP slaves | ✅ Yes | ✅ Yes | Varies |
| Proficy ME configuration | ✅ Yes | ✅ Yes | ❌ No |
| Drop-in hardware swap | ✅ CA revision | ✅ CB/CC revision | ❌ Requires re-engineering |
| New system design | ⚠️ Legacy revision | ✅ Recommended | ✅ If migrating platform |
Recommendation: For existing RX3i systems running CA firmware, the IC695PBM300CA is the safest drop-in replacement. For new designs, consider the CB or CC revision for extended support lifecycle.
Quality Assurance & Sourcing
- ✅ Original manufacturer parts — sourced from authorized distribution channels
- ✅ Pre-shipment inspection — visual, label, and functional verification
- ✅ Anti-counterfeit screening — serial number and date code validation
- ✅ Secure packaging — ESD-safe bags, foam-lined boxes, and tamper-evident seals
- ✅ Traceability documentation — CoC and test reports available on request
- ✅ Global shipping — DHL / FedEx / UPS express with full tracking
How to Order
- Confirm your part number: IC695PBM300CA
- Verify your RX3i backplane slot availability and power budget
- Add to cart or contact us for bulk/project pricing
- Provide your shipping address and preferred carrier
- Receive order confirmation with tracking within 24 hours
📧 Email: support@konmask.com
📞 Phone/WhatsApp: +0086 19859288691
🌐 Website: https://Konmask.com
Replacement & Compatibility FAQ
Q: Is IC695PBM300CA the same as IC695PBM300?
A: Yes, the CA suffix denotes the hardware/firmware revision. The IC695PBM300 (no suffix) is the original release; CA is a later, more stable revision. They are functionally identical and physically interchangeable.
Q: Can I replace IC695PBM300CA with IC695PBM300CB?
A: Yes. The CB revision is a direct drop-in replacement with the same form factor and backplane interface. Firmware may differ slightly; update via Proficy Machine Edition after installation.
Q: Will a Siemens CP343-5 replace the IC695PBM300CA?
A: Not directly. The CP343-5 is a PROFIBUS DP Master for the Siemens S7-300 platform. It performs the same network role but requires a completely different hardware platform and control program. It is a cross-brand functional equivalent, not a drop-in replacement.
Q: What software is needed to configure the IC695PBM300CA?
A: GE Proficy Machine Edition (PME) is required. The module is configured via the Hardware Configuration tool within PME, where you define the PROFIBUS network, slave GSD files, and I/O mapping.
Q: Do you provide a warranty?
A: Yes. All modules supplied by Konmask.com include a 12-month warranty against manufacturing defects. Expedited replacement is available for critical production environments.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691






