Power System Protection Solution – GE UR6CH Universal Relay | UR Series
Where This Product Is Used
The GE UR6CH Universal Relay is a field-proven protection relay deployed across high-voltage substations, industrial power distribution systems, and utility-grade transmission networks. Engineers specify the UR6CH in the following environments:
- Utility Substations (115 kV – 500 kV): Line, transformer, and bus differential protection schemes where IEC 61850 GOOSE messaging is mandatory.
- Industrial Power Plants & Refineries: Generator protection, motor feeder backup, and arc-flash mitigation in petrochemical and mining facilities.
- Renewable Energy Integration: Wind farm collector systems and solar PV interconnection protection requiring fast fault clearance (<30 ms).
- Rail & Transit Infrastructure: Traction power substation protection where high reliability and redundant I/O are critical.
- Data Center Critical Power: Medium-voltage switchgear protection for Tier III/IV facilities demanding zero unplanned downtime.
Technical Specifications
| Model / SKU | UR6CH |
| Series | UR (Universal Relay) Series |
| Manufacturer | GE Grid Solutions (General Electric) |
| Form Factor | 19-inch rack-mount, 6U chassis |
| I/O Channels | 6-channel configurable analog/digital I/O |
| Rated Voltage | 100–240 V AC / 110–250 V DC (wide-range) |
| Current Input | 1 A / 5 A selectable CT input |
| Communication Protocols | IEC 61850 Ed.2, DNP3, Modbus RTU/TCP, IEC 60870-5-103 |
| Protection Functions | ANSI 21, 27, 32, 46, 47, 49, 50/51, 59, 67, 79, 81, 87 (configurable) |
| Operating Temperature | -40 °C to +85 °C |
| Weight | 900 g |
| Certifications | CE, UL, IEC 60255, IEEE C37.90 |
Why Engineers Specify This Model
- Flexible 6-Channel Architecture: The UR6CH’s modular I/O slots allow engineers to configure the relay for line, transformer, bus, or generator protection without ordering a dedicated single-function device — reducing spare-parts inventory by up to 40%.
- IEC 61850 GOOSE & Sampled Values: Native support eliminates copper wiring between bays, cutting substation commissioning time and enabling peer-to-peer tripping schemes.
- Cybersecurity Hardened: Role-based access control (RBAC), encrypted communications, and NERC CIP compliance features built in — no third-party add-ons required.
- EnerVista Software Suite: GE’s EnerVista UR Setup software provides drag-and-drop logic programming, real-time oscillography, and remote firmware updates.
- Proven Field Reliability: UR Series relays are installed in 100+ countries with a documented MTBF exceeding 200,000 hours.
Complete System Bill of Materials
For a complete UR6CH-based protection panel, engineers typically source the following companion components:
- GE UR Series Chassis (6-slot or 8-slot) – UR-6H / UR-8H
- GE UR CPU Module – 9G-CPU-001 or 9G-CPU-002
- GE UR AC/DC Power Supply Module – 9G-PSU-001
- GE UR CT/VT Input Module – 9G-8CT / 9G-4CT4VT
- GE UR Digital Output Module – 9G-8DO / 9G-16DO
- GE UR Ethernet Communication Card – 9G-ETH-001 (IEC 61850)
- GE EnerVista UR Setup Software License
- Shielded Cat6 Ethernet Cable (IEC 61850 network)
Contact Konmask.com for bundle pricing on complete UR6CH panel kits.
Compliance & Industry Standards
- IEC 60255 – Measuring Relays and Protection Equipment
- IEC 61850 Ed.2 – Communication Networks and Systems in Substations
- IEEE C37.90 – Relays and Relay Systems Associated with Electric Power Apparatus
- NERC CIP-002 through CIP-014 – Critical Infrastructure Protection
- CE Marking – EU Low Voltage Directive & EMC Directive
- UL Listed – Underwriters Laboratories
- RoHS Compliant
Quality Assurance & Sourcing
Konmask.com sources the GE UR6CH exclusively through authorized distribution channels and verified surplus markets. Every unit undergoes:
- Visual inspection and physical verification against GE factory serial number records
- Firmware version check and documentation of installed software revision
- Functional power-on test with communication port verification
- Anti-static packaging with humidity indicator cards for international shipment
All products are shipped with a 90-day Konmask warranty and full traceability documentation.
How to Source This Part
Ready to procure the GE UR6CH for your project? Here’s how to get started:
- Add to Cart: In-stock units ship within 1–3 business days from our warehouse.
- Request a Quote: For volume orders (>5 units) or project-based procurement, email support@konmask.com for a formal quotation with lead time confirmation.
- Technical Pre-Sales: Our engineering team can review your single-line diagram and confirm the UR6CH is the correct relay for your protection scheme.
- Global Shipping: We ship to 50+ countries via DHL Express, FedEx International, and sea freight for large orders.
Application-Specific FAQ
Q: Can the UR6CH replace an older GE D60 or L90 relay?
A: Yes. The UR6CH shares the same UR platform chassis and communication architecture. With appropriate module selection and EnerVista configuration, it can replicate D60 line differential or L90 line current differential functions.
Q: Is the UR6CH compatible with IEC 61850 Edition 2 SCL files?
A: Yes. The UR6CH supports ICD/CID/SCD file import/export for seamless integration with substation automation systems (SAS) and SCADA platforms.
Q: What firmware version is shipped?
A: Units are shipped with the firmware version as received. Konmask documents the installed version; GE EnerVista software can upgrade firmware on-site or remotely.
Q: Can this relay be used in a redundant protection scheme?
A: Yes. The UR6CH supports dual-redundant Ethernet ports and can participate in PRP (Parallel Redundancy Protocol) or HSR (High-availability Seamless Redundancy) network topologies.
Q: Do you provide a test report or calibration certificate?
A: A functional test report is available upon request. Third-party NIST-traceable calibration certificates can be arranged for an additional fee.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691