Process Control Solution – Honeywell 05701-A-0325 | ST 3000 Series Pressure Transmitter
Where This Product Is Used
The Honeywell 05701-A-0325 is a high-accuracy pressure transmitter from the ST 3000 Series, engineered for demanding industrial process environments. It is widely deployed in:
- Oil & Gas: Wellhead pressure monitoring, pipeline differential pressure measurement, separator level control
- Chemical & Petrochemical Plants: Reactor vessel pressure, distillation column DP, tank level via hydrostatic head
- Power Generation: Boiler drum level, steam header pressure, feedwater flow measurement
- Pulp & Paper / Water Treatment: Filter differential pressure, pump suction/discharge monitoring
- Pharmaceutical Manufacturing: Clean-room pressure differential, sterile process vessel monitoring
Technical Specifications
- Model: 05701-A-0325
- Series: ST 3000 Smart Transmitter
- Manufacturer: Honeywell Process Solutions
- Measurement Type: Gauge / Differential Pressure
- Output Signal: 4–20 mA HART
- Accuracy: ±0.075% of span (reference conditions)
- Turndown Ratio: Up to 100:1
- Process Connection: 1/4″ NPT or 1/2″ NPT (per configuration)
- Wetted Materials: 316L Stainless Steel / Hastelloy C (optional)
- Enclosure Rating: IP66 / NEMA 4X
- Ambient Temperature: -40°C to +85°C
- Power Supply: 10.5–55 VDC (loop-powered)
- Weight: ~500 g
- Country of Origin: USA
Why Engineers Specify This Model
- Proven ST 3000 Platform: Decades of field reliability in critical process loops across global refineries and power plants
- HART Communication: Full digital diagnostics, remote configuration, and integration with DCS/SCADA systems (Honeywell Experion, Emerson DeltaV, Siemens PCS 7)
- High Turndown Flexibility: One transmitter covers a wide measurement range, reducing spare-parts inventory
- Robust Construction: IP66-rated housing withstands washdown, humidity, and corrosive atmospheres
- Plug-and-Play Replacement: Direct drop-in replacement for existing ST 3000 installations — no re-wiring or re-calibration of loop required
- SIL Capability: Suitable for use in Safety Instrumented Systems (SIS) per IEC 61508
Complete System Bill of Materials
For a complete pressure measurement loop using the 05701-A-0325, engineers typically specify:
- Honeywell 05701-A-0325 — Pressure Transmitter (this unit)
- Honeywell MC-TAIH02 or equivalent — HART Multiplexer / I/O Card
- 2-valve or 5-valve manifold (SS316L) — Isolation & equalization
- Impulse tubing (1/2″ SS316) — Process connection piping
- DIN rail 24 VDC power supply — Loop power
- HART Communicator (e.g., Emerson 475) — Field configuration tool
- Cable gland M20 × 1.5 (Ex-rated if hazardous area) — Cable entry
Compliance & Industry Standards
- CE Marking — EU Pressure Equipment Directive (PED)
- ATEX / IECEx — Intrinsically Safe (Ex ia) and Explosion-proof (Ex d) options available
- FM / CSA — North American hazardous location approvals
- IEC 61508 SIL 2 — Functional Safety compliance
- NAMUR NE 43 — Standardized signal levels for fault indication
- ISO 9001:2015 — Honeywell manufacturing quality system
Quality Assurance & Sourcing
Konmask.com sources the Honeywell 05701-A-0325 through authorized industrial distribution channels. Every unit is:
- Inspected for physical integrity and original factory seals upon receipt
- Verified against Honeywell part number and date code documentation
- Stored in ESD-safe, climate-controlled warehouse conditions
- Shipped with original manufacturer documentation where available
We do not sell grey-market, refurbished, or counterfeit components. Traceability documentation available upon request for MRO and EPC procurement teams.
How to Source This Part
- In Stock: Ready to ship within 1–3 business days
- Lead Time (if on order): 4–8 weeks from Honeywell factory
- MOQ: 1 unit
- Bulk / Project Pricing: Contact us for BOM-level quotes on 5+ units
- Export: Available for worldwide shipping; export documentation (CO, packing list, commercial invoice) provided
- Payment: T/T, L/C, PayPal, and major credit cards accepted
📧 support@konmask.com | 📞 +0086 19859288691
Application-Specific FAQ
Q: Can the 05701-A-0325 be used in hazardous (Ex) areas?
A: Yes. With the appropriate ATEX/IECEx or FM/CSA certification option, it is rated for Zone 1/2 (gas) and Zone 21/22 (dust) hazardous locations. Confirm the exact approval suffix on your order.
Q: Is this transmitter compatible with Honeywell Experion PKS?
A: Yes. The ST 3000 series integrates natively with Honeywell Experion via HART I/O cards. Full device description (DD) files are available from Honeywell’s Field Device Library.
Q: What is the difference between 05701-A-0325 and 05701-A-0326?
A: The suffix digits encode range, process connection, and fill fluid options. The -0325 variant specifies a particular span and wetted material configuration. Contact our technical team to confirm the correct suffix for your application.
Q: Can I get a calibration certificate with this unit?
A: Factory calibration certificates are available for new units. Third-party NIST-traceable calibration can be arranged upon request at additional cost.
Q: What is the warranty?
A: New units carry Honeywell’s standard 18-month warranty from date of shipment. Konmask.com provides 90-day return/exchange on DOA units.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com