ICS TRIPLEX TC-011-02-1M5 Fan Power Cable | Replacement, Equivalent & Selection Guide
The ICS TRIPLEX TC-011-02-1M5 is a dedicated fan power cable designed for use within ICS TRIPLEX Trusted Control System (TMR) enclosures and chassis. It provides reliable power delivery to cooling fans, ensuring thermal management integrity in safety-critical industrial automation environments. Konmask.com supplies genuine and compatible units with full traceability.
Technical Specifications
- Part Number: TC-011-02-1M5
- Manufacturer: ICS TRIPLEX
- Series: Trusted Control System (TMR)
- Cable Type: Fan Power Cable
- Cable Length: Approximately 1.5 m (1M5 suffix)
- Connector Type: Proprietary ICS TRIPLEX keyed power connector
- Voltage Rating: Compatible with standard 24 VDC fan supply rails
- Weight: 2,680 g (packaged)
- Operating Temperature: -20°C to +70°C
- Application: Internal chassis fan power distribution
- Compliance: Designed for use in SIL-rated TMR safety systems
Compatible Replacement & Equivalent Models
If the TC-011-02-1M5 is unavailable or end-of-life, the following alternatives may be considered depending on your chassis revision and fan assembly:
- TC-011-02-1M0 – Shorter 1.0 m variant; verify routing clearance before substitution
- TC-011-02-2M0 – Longer 2.0 m variant; suitable for extended-depth enclosures
- ICS TRIPLEX OEM Fan Cable Kit – Bundled replacement kit for full chassis fan arrays
- Custom-length equivalent – Contact Konmask.com for custom cable fabrication to original ICS TRIPLEX specifications
Note: Always verify connector pinout and voltage compatibility before substituting any cable assembly in a TMR safety system.
Why Choose the Original TC-011-02-1M5
- Factory-specified cable length (1.5 m) optimized for standard ICS TRIPLEX TMR rack depth
- Keyed connectors prevent mis-wiring in high-density chassis environments
- Manufactured to ICS TRIPLEX quality standards for use in SIL 1–3 certified systems
- Full OEM traceability — critical for functional safety audits and maintenance records
- Minimizes downtime risk: drop-in replacement with zero re-engineering
Typical Applications
- ICS TRIPLEX Trusted TMR Controller chassis fan power distribution
- Replacement during scheduled preventive maintenance of TMR enclosures
- Spare parts inventory for oil & gas, petrochemical, and power generation plants
- Upgrade or refurbishment of legacy ICS TRIPLEX safety systems
- Emergency replacement to restore cooling in critical control environments
System Compatibility
- ICS TRIPLEX Trusted TMR Controller – T8000 series and compatible chassis
- ICS TRIPLEX T8110 / T8120 / T8130 – Processor and I/O modules requiring fan-cooled enclosures
- ICS TRIPLEX T8800 Series – Power supply and fan tray assemblies
- Consult your system BOM or contact Konmask.com to confirm compatibility with your specific chassis revision.
Selection Guide
| Requirement | Recommended Model |
|---|---|
| Standard TMR rack depth (1.5 m routing) | TC-011-02-1M5 ✓ (this model) |
| Compact enclosure (<1.0 m routing) | TC-011-02-1M0 |
| Extended enclosure (>1.5 m routing) | TC-011-02-2M0 |
| Full fan array replacement | ICS TRIPLEX Fan Cable Kit |
| Non-standard length required | Custom fabrication — contact us |
Quality Assurance & Sourcing
- All units sourced from authorized ICS TRIPLEX distributors or verified surplus channels
- Each cable inspected for connector integrity, insulation condition, and labeling accuracy
- Serialized documentation available upon request for safety-system traceability
- Export-compliant packaging with country-of-origin declaration
- Konmask.com maintains stock of critical ICS TRIPLEX spare parts for rapid dispatch
How to Order
- Confirm your chassis model and fan assembly revision from your system BOM
- Verify cable routing length requirement (1.5 m for TC-011-02-1M5)
- Add to cart or contact [email protected] for bulk/project pricing
- Provide your PO number, delivery address, and any traceability documentation requirements
- Typical lead time: 3–7 business days for in-stock units; expedited options available
Replacement & Compatibility FAQ
Q: Can I use a longer cable (TC-011-02-2M0) as a direct replacement?
A: Yes, provided the additional cable length can be safely routed and secured within the enclosure without obstructing airflow or other components.
Q: Is the TC-011-02-1M5 compatible with non-ICS TRIPLEX fan assemblies?
A: The connector is proprietary to ICS TRIPLEX. Use with third-party fans requires adapter verification — contact us for guidance.
Q: Do you supply documentation for safety system maintenance records?
A: Yes. Konmask.com can provide material certificates, test records, and sourcing declarations upon request.
Q: What is the lead time for out-of-stock units?
A: Typically 2–4 weeks for factory-new units. Refurbished or surplus units may be available sooner — inquire directly.
Q: Can Konmask.com fabricate a custom-length fan power cable?
A: Yes. Contact us with your connector type, length, and voltage requirements for a custom quotation.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: [email protected] | +0086 19859288691