In a continuous process plant—whether it’s an oil refinery, chemical reactor, or offshore platform—a single point of power failure on a FOUNDATION Fieldbus H1 segment can cascade into unplanned shutdowns, lost production, and costly emergency maintenance. Without a dedicated redundant power conditioner, every field device on that segment becomes vulnerable: flow transmitters go blind, control valves freeze in position, and operators lose visibility at the worst possible moment. The MTL RELCOM F802 exists precisely to eliminate that risk.
The RELCOM F802 is MTL Instruments’ dual-redundant fieldbus power conditioner engineered for FOUNDATION Fieldbus H1 and PROFIBUS PA segments. Within the globally trusted RELCOM series—MTL’s dedicated line of fieldbus infrastructure components—the F802 occupies the critical tier of high-availability power supply, delivering seamless active redundancy that meets the stringent demands of SIL-rated process control environments. It is deployed across refineries, LNG terminals, pharmaceutical plants, and water treatment facilities on every continent.
Technical Specifications
- Model: MTL F802 / RELCOM F802
- Function: Redundant Fieldbus Power Conditioner
- Compatible Protocols: FOUNDATION Fieldbus H1, PROFIBUS PA
- Redundancy Mode: Active-active dual redundancy (hot standby)
- Output Voltage: Regulated fieldbus-compliant DC output
- Impedance: High impedance to fieldbus signal (per IEC 61158-2)
- Segment Support: Single H1/PA segment per unit
- Mounting: DIN rail
- Weight: 1,760 g
- Standards: IEC 61158-2, ATEX / IECEx compatible configurations available
- Manufacturer: MTL Instruments (RELCOM brand)
Note: All specifications are based on published MTL/RELCOM documentation. Contact Konmask.com for the latest datasheet.
Key Features & Benefits
- True Active Redundancy: Both power modules operate simultaneously; if one fails, the other sustains the segment without interruption or manual switchover.
- Signal Integrity Protection: High-impedance design prevents power supply noise from corrupting fieldbus communication signals.
- Hot-Swap Capability: Failed modules can be replaced under live conditions, eliminating the need for segment shutdown during maintenance.
- Compact DIN Rail Form Factor: Optimized for marshalling cabinet and junction box integration in space-constrained installations.
- Wide Industrial Compatibility: Supports all major FOUNDATION Fieldbus H1 and PROFIBUS PA field devices from leading vendors (Emerson, Yokogawa, ABB, Endress+Hauser, etc.).
- Reduced Lifecycle Cost: Eliminates segment downtime events, dramatically reducing the total cost of ownership versus non-redundant alternatives.
Industry & Equipment Applications
- Oil & Gas: Upstream wellhead control, midstream pipeline monitoring, downstream refinery DCS integration
- Petrochemical & Chemical: Reactor control loops, distillation column instrumentation
- LNG & Offshore: Platform safety instrumented systems (SIS) requiring high-availability fieldbus power
- Pharmaceutical & Food & Beverage: FDA/GMP-compliant process control with validated fieldbus infrastructure
- Power Generation: Turbine control and boiler management systems
- Water & Wastewater: SCADA-integrated treatment plant automation
System Integration & Compatible Parts
The MTL RELCOM F802 is designed to integrate seamlessly within the broader RELCOM fieldbus infrastructure ecosystem. Compatible and complementary components include:
- RELCOM F10 / F11 Fieldbus Segment Protectors
- MTL fieldbus barriers and isolators (MTL5000 / MTL7000 series)
- RELCOM FPS fieldbus power supplies (non-redundant variants)
- DCS host systems: Emerson DeltaV, Honeywell Experion, Yokogawa CENTUM, ABB 800xA
- Standard IEC 61158-2 compliant H1 field devices
Our Quality Assurance Process
At Konmask.com, every MTL RELCOM F802 unit we supply undergoes a rigorous sourcing and verification process:
- Authorized Supply Chain: Units are sourced exclusively from verified distributors and authorized channels to guarantee authenticity.
- Visual & Marking Inspection: Each unit is inspected for correct labeling, serial number integrity, and physical condition before dispatch.
- Documentation Package: Original manufacturer documentation, certificates of conformity, and test records are provided upon request.
- Traceability: Full supply chain traceability is maintained for every order to support your site audit requirements.
How to Order
- Submit your inquiry via the Contact / RFQ form on this page or email [email protected].
- Provide your required quantity, delivery timeline, and destination country.
- Our technical team will confirm availability, lead time, and issue a formal quotation within 24 hours.
- Upon PO confirmation, we arrange secure packaging and international freight with full export documentation.
Why Choose Konmask.com?
- Specialized in industrial automation and process control components for B2B buyers worldwide
- Deep technical expertise in fieldbus infrastructure, DCS, and PLC ecosystems
- Fast global shipping with DHL, FedEx, and UPS express options
- Dedicated pre-sales engineering support for compatibility verification
- Competitive pricing with volume discount programs for OEMs and EPC contractors
- Responsive after-sales support and RMA handling
Frequently Asked Questions
Q: What is the difference between the MTL F802 and a standard (non-redundant) fieldbus power supply?
A: The F802 uses two active power modules operating in parallel. If one module fails, the other continues to power the segment without any interruption. A standard single-module supply would cause a complete segment outage on failure.
Q: Is the RELCOM F802 compatible with PROFIBUS PA as well as FOUNDATION Fieldbus H1?
A: Yes. The F802 is designed to comply with IEC 61158-2 physical layer requirements, which are shared by both FOUNDATION Fieldbus H1 and PROFIBUS PA protocols.
Q: Can I replace a failed module while the segment is live?
A: Yes. The hot-swap design allows module replacement under energized conditions, provided your site safety procedures permit live work on the cabinet.
Q: What DCS systems has the F802 been validated with?
A: The F802 has been used with Emerson DeltaV, Honeywell Experion PKS, Yokogawa CENTUM VP, and ABB 800xA, among others. Contact us for specific compatibility documentation.
Q: How do I request a datasheet or certificate of conformity?
A: Email [email protected] with your order reference or inquiry number and we will provide the full documentation package.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: [email protected] | +0086 19859288691