The SICK ICR620S-T11503 is a high-performance industrial bar code reader designed for demanding factory automation and logistics environments. This page provides complete technical specifications, compatible replacement models, application guidance, and sourcing information to help engineers and procurement teams make confident selection decisions.
Technical Specifications
| Manufacturer | SICK AG |
| Part Number | ICR620S-T11503 |
| Series | ICR620S |
| Device Type | Industrial Bar Code Reader (Stationary) |
| Reading Technology | Laser / CCD Imaging |
| Supported Code Types | 1D: Code 128, Code 39, EAN/UPC, Interleaved 2/5, Codabar; 2D: DataMatrix, QR Code (model-dependent) |
| Interface | RS-232, RS-422, Ethernet (model-dependent) |
| Supply Voltage | 10–30 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Protection Rating | IP 65 |
| Weight | approx. 500 g |
| Configuration Software | SOPAS Engineering Tool |
| Certifications | CE, UL (region-dependent) |
Note: Specifications are based on published SICK datasheet data. Confirm exact parameters with the official SICK datasheet before final design-in.
Compatible Replacement & Equivalent Models
When the ICR620S-T11503 is discontinued, out of stock, or cost-prohibitive, the following models are commonly evaluated as functional equivalents. Always verify electrical, mechanical, and software compatibility before substitution.
| Model | Brand | Key Similarity | Notes |
|---|---|---|---|
| ICR620S-T11501 | SICK | Same series, different variant | Check suffix for interface/optics differences |
| ICR620S-T11505 | SICK | Same series, extended range | Confirm reading distance requirements |
| CLV620-0120 | SICK | CLV series, similar performance tier | Different form factor; widely available |
| CLV651-0120S01 | SICK | Higher-end CLV, Ethernet native | Upgrade path for network-integrated lines |
| MS-3 / MS-4 | Keyence | Cross-brand alternative | Requires interface adapter; strong read rate |
| DM3610 | Cognex | Cross-brand, 1D/2D capable | Higher cost; superior decode algorithm |
Need help confirming compatibility? Contact our technical team at [email protected] with your application details.
Why Choose the Original Model
- Proven field reliability — SICK ICR620S series has extensive deployment history in automotive, logistics, and food & beverage lines.
- Native SOPAS integration — seamless configuration, diagnostics, and parameter cloning via SICK’s own engineering tool.
- Guaranteed OEM compatibility — no adapter cables, no firmware workarounds, no integration risk.
- Spare parts ecosystem — mounting brackets, cables, and accessories are standardized across the ICR620 family.
- Long-term support — SICK provides firmware updates and technical documentation for the full product lifecycle.
Typical Applications
- Conveyor-based parcel and carton identification in warehouse & distribution centers
- Automotive body-in-white (BIW) part tracking on assembly lines
- Pharmaceutical serialization and track-and-trace compliance
- Food & beverage date-code and batch verification
- Electronics PCB and component traceability
- Postal and courier sortation systems
System Compatibility
- PLC / Controller: Siemens S7-300/400/1200/1500, Allen-Bradley ControlLogix/CompactLogix, Mitsubishi Q/iQ-R series, Omron NJ/NX series
- Fieldbus / Network: PROFIBUS DP, PROFINET, EtherNet/IP, Modbus TCP (via gateway or native Ethernet variant)
- SCADA / MES: Compatible with standard serial and Ethernet data forwarding; integrates with Siemens WinCC, Ignition, and most OPC-UA-capable platforms
- SICK Ecosystem: MSC800 bar code controller, Flexi Soft safety controller (for interlock applications), SICK Inspector vision systems
Selection Guide
Use the criteria below to confirm the ICR620S-T11503 is the right choice — or to identify a better-fit alternative:
| Requirement | ICR620S-T11503 | Consider Instead |
|---|---|---|
| Reading distance < 300 mm | ✅ Suitable | — |
| Reading distance 300–800 mm | ⚠️ Check optics suffix | CLV620 long-range variant |
| 2D code reading required | ⚠️ Confirm model suffix | ICR890 / Cognex DM3610 |
| Ethernet/IP native required | ⚠️ Check suffix -T115xx | CLV651 Ethernet variant |
| Harsh environment (IP67+) | ❌ IP65 only | SICK CLV680 (IP67) |
| Budget-sensitive replacement | — | ICR620S-T11501 or CLV620 |
| Drop-in OEM replacement | ✅ Best choice | — |
Quality Assurance & Sourcing
- Authentic stock only — Konmask.com sources exclusively from authorized distributors and verified industrial surplus channels.
- Pre-shipment inspection — every unit undergoes visual inspection and, where applicable, power-on functional verification.
- Traceability — batch records and supplier documentation available on request for regulated industries.
- Warranty — 90-day replacement warranty on all stocked units; extended warranty available on request.
- Anti-counterfeit — SICK holograms, label integrity, and serial number cross-reference checked before dispatch.
How to Order
- Confirm the exact part number: SICK ICR620S-T11503 (check suffix carefully — each suffix denotes a specific optic/interface combination).
- Add to cart and proceed to checkout, or contact us for bulk/project pricing.
- For urgent requirements, email [email protected] with quantity, delivery location, and required lead time.
- Export documentation (commercial invoice, packing list, CO) provided for international shipments.
Phone / WhatsApp: +0086 19859288691
Email: [email protected]
Website: https://Konmask.com
Replacement & Compatibility FAQ
Q: Is the ICR620S-T11503 still in production?
A: SICK periodically updates its ICR product line. Contact us to confirm current production status and available stock.
Q: Can I replace an ICR620S-T11503 with a CLV620 without rewiring?
A: In most cases, yes — both use the same M12 connector pinout for power and serial. Verify the interface type (RS-232 vs. RS-422) matches your controller port.
Q: Does the ICR620S-T11503 read DataMatrix or QR codes?
A: The base ICR620S series is primarily a 1D laser reader. 2D capability depends on the specific suffix variant. Contact us to confirm your unit’s capability.
Q: What cable do I need?
A: SICK part number DOS0000 (power/IO) and DOS0001 (serial data) are the standard accessories. We can supply cables alongside the reader.
Q: Can you supply a test report or FAT document?
A: Yes — factory acceptance test documentation is available for project orders. Please request at time of order.
© 2026 Konmask.com. All rights reserved.