Allen-Bradley 2711P-T12C6D2 – 12.1″ Color Touch HMI Terminal | PanelView Plus 6 Platform
Engineering Background
The Allen-Bradley 2711P-T12C6D2 is a high-performance human-machine interface (HMI) terminal from Rockwell Automation’s PanelView Plus 6 series. Designed for demanding industrial environments, this unit delivers a 12.1-inch SVGA color touchscreen with integrated FactoryTalk View ME runtime, enabling seamless visualization and control across a wide range of automation architectures. It is the preferred choice for engineers requiring a robust, scalable, and network-ready operator interface in discrete and process manufacturing applications.
Product Positioning
The 2711P-T12C6D2 occupies the mid-to-large display tier within the PanelView Plus 6 family, bridging the gap between compact panels and full-scale SCADA workstations. Its dual-port EtherNet/IP connectivity and native ControlLogix/CompactLogix integration make it the standard specification for new panel builds and legacy system upgrades across automotive, food & beverage, oil & gas, and water treatment sectors.
Complete Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | 2711P-T12C6D2 |
| Series | PanelView Plus 6 |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Display Size | 12.1 inch (diagonal) |
| Display Type | TFT Color LCD, SVGA |
| Resolution | 800 × 600 pixels |
| Touch Technology | Analog Resistive Touchscreen |
| Backlight | LED |
| Processor | Intel Atom 1.6 GHz |
| RAM | 512 MB DDR2 |
| Storage | 512 MB CompactFlash (internal) |
| Operating System | Windows CE 6.0 |
| HMI Software | FactoryTalk View ME (pre-installed runtime) |
| Communication Ports | 2× EtherNet/IP (RJ-45, dual-port switch), 1× RS-232, 2× USB 2.0 Host, 1× USB 2.0 Device |
| Network Protocol | EtherNet/IP, DH-485 (via adapter) |
| Input Voltage | 24 VDC (18–32 VDC operating range) |
| Power Consumption | ≤ 40 W typical |
| Operating Temperature | 0 °C to +55 °C |
| Storage Temperature | -20 °C to +70 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Enclosure Rating | NEMA 4/4X, 12, 13; IP65 (front face) |
| Vibration Resistance | IEC 60068-2-6: 5–500 Hz, 2 g |
| Shock Resistance | IEC 60068-2-27: 15 g, 11 ms |
| Certifications | UL, CE, cUL, C-Tick |
| Panel Cutout | 340 mm × 268 mm (W × H) |
| Overall Dimensions | 368 mm × 296 mm × 73 mm (W × H × D) |
| Weight | Approx. 2.9 kg |
| Mounting | Panel mount (front), landscape orientation |
| Catalog Suffix Decode | T = Touch; 12 = 12.1″; C = Color; 6 = Series 6; D2 = DC power, dual EtherNet/IP |
Proven Application Environments
- Automotive Assembly Lines — Real-time visualization of conveyor, robot, and press status with ControlLogix integration
- Food & Beverage Processing — Washdown-rated front panel (IP65) suitable for CIP/SIP environments
- Oil & Gas Wellhead & Skid Control — Wide temperature tolerance and vibration resistance for field-mounted panels
- Water & Wastewater Treatment — SCADA-edge visualization with EtherNet/IP to remote I/O and drives
- Pharmaceutical Manufacturing — Audit-trail capable via FactoryTalk Security integration
- Building Automation & Utilities — Energy monitoring dashboards with trend displays and alarm management
- Machine OEM Panels — Standard platform for multi-axis motion and safety system HMI
Engineering Advantages
- Dual EtherNet/IP Ports — Built-in device-level ring (DLR) support eliminates the need for external managed switches in ring topologies
- FactoryTalk View ME Native Runtime — No additional software license required for runtime operation; full tag-based alarming, trending, and recipe management
- Seamless Logix Integration — Direct tag browsing to ControlLogix, CompactLogix, and GuardLogix controllers without intermediate OPC servers
- LED Backlight Longevity — Rated for 50,000+ hours MTBF, reducing planned maintenance intervals versus CCFL predecessors
- USB Peripheral Support — Supports barcode scanners, printers, and USB drives for recipe download and data logging
- Scalable Application Migration — FactoryTalk View ME applications are portable across the entire PanelView Plus 6 family; resize and redeploy without full redesign
- NEMA 4X / IP65 Front Face — Suitable for outdoor enclosures and high-pressure washdown without additional sealing
System Architecture & Signal Flow
The 2711P-T12C6D2 operates as an EtherNet/IP Class 1 and Class 3 device. In a typical architecture:
- Controller Layer: ControlLogix or CompactLogix PLC communicates via EtherNet/IP to the panel’s Port 1 (primary network).
- Device Ring (DLR): Port 2 daisy-chains to the next device in the ring, providing fault-tolerant network redundancy without a managed switch.
- HMI Runtime: FactoryTalk View ME polls controller tags at configurable update rates (default 500 ms); alarm states are evaluated on-panel.
- Data Logging: Trend data and alarm history are stored to internal CompactFlash or exported via USB to removable media.
- Remote Access: FactoryTalk ViewPoint (optional server license) enables browser-based remote monitoring over the plant LAN.
Signal flow: Field Sensors → PLC I/O → Controller Tag Database → EtherNet/IP → PanelView Plus HMI → Operator Display & Input → Controller Write-Back
Sourcing & Quality Verification
- Origin: Sourced from authorized distributors and verified surplus channels; all units are Allen-Bradley genuine.
- Inspection Protocol: Each unit undergoes visual inspection (housing, connectors, label integrity), power-on functional test, and firmware version verification prior to shipment.
- Warranty: 90-day operational warranty against defects in materials and workmanship. Extended warranty available upon request.
- Traceability: Serial number and date code recorded at intake; available to buyer upon request for maintenance records.
- Packaging: Anti-static bag + foam-lined carton; meets ISTA 2A transit testing standards.
Procurement Process
- Inquiry: Submit your part number, required quantity, and delivery timeline via the contact form or email below.
- Quotation: Receive a formal quotation with unit price, lead time, and shipping options within 1 business day.
- Order Confirmation: Purchase order or online checkout accepted; proforma invoice issued for wire transfer payments.
- Quality Hold: Unit reserved and final inspection completed upon order confirmation.
- Shipment: DHL / FedEx / SF Express with full tracking; export documentation (commercial invoice, packing list, COO) provided for international orders.
- After-Sales: Technical support available via email for installation, commissioning, and FactoryTalk View ME application queries.
Technical FAQ
Q: Is the 2711P-T12C6D2 compatible with MicroLogix or SLC 500 controllers?
A: Yes, via EtherNet/IP or RS-232 DF1 protocol. A FactoryTalk View ME application must be configured with the appropriate communication driver (e.g., DF1, DH-485 via 1761-NET-AIC adapter).
Q: What version of FactoryTalk View ME Studio is required to develop applications for this panel?
A: FactoryTalk View ME Studio v6.0 or later is recommended. Applications developed in later versions (v8.x, v9.x) are backward-compatible with the panel’s runtime if the feature set is within v6.x scope.
Q: Can the internal CompactFlash be replaced or upgraded?
A: The internal CF card is field-replaceable. Rockwell Automation recommends using only approved CF cards (Cat. No. 2711P-RCF512) to ensure compatibility and reliability.
Q: Does this unit support FactoryTalk Security for user authentication?
A: Yes. FactoryTalk Security is integrated into the ME runtime, supporting local user accounts and network directory authentication for role-based access control.
Q: What is the difference between 2711P-T12C6D2 and 2711P-T12C6D1?
A: The D2 suffix denotes dual EtherNet/IP ports with DLR support. The D1 suffix has a single EtherNet/IP port. The D2 is the preferred specification for new installations requiring network redundancy.
Q: Is CE marking included for European import?
A: Yes. The 2711P-T12C6D2 carries CE marking per EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. Declaration of Conformity available upon request.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691