GE IC695PNS001 PROFINET IO Controller Scanner – PACSystems RX3i Series
When a PROFINET IO scanner fails on the plant floor, the consequences are immediate and severe: distributed IO devices go offline, production lines halt, and engineering teams scramble under pressure to source a replacement. In high-throughput manufacturing, automotive assembly, or process control environments, every minute of unplanned downtime translates directly into lost revenue and missed delivery commitments. The GE IC695PNS001 is the critical link that keeps your PROFINET IO network alive — and without it, your entire distributed control architecture is at risk.
The IC695PNS001 is GE’s dedicated PROFINET IO Controller Scanner module for the PACSystems RX3i platform — one of the most widely deployed mid-to-high-end PLC systems in global industrial automation. Positioned as the primary PROFINET interface within the RX3i backplane, this module enables the CPU to communicate with up to 128 PROFINET IO devices across a standard Ethernet network, making it indispensable for modern, open-architecture control systems. Its adoption spans automotive OEMs, food & beverage plants, oil & gas facilities, and discrete manufacturing lines worldwide.
Technical Specifications
- Part Number: IC695PNS001
- Series: PACSystems RX3i
- Manufacturer: GE (GE Automation & Controls / GE Fanuc)
- Module Type: PROFINET IO Controller Scanner
- Communication Protocol: PROFINET IO (IRT / RT)
- Max IO Devices Supported: Up to 128 PROFINET IO devices
- Network Interface: 2 × RJ45 Ethernet ports (integrated switch)
- Backplane Compatibility: RX3i Universal Backplane (IC695CHS007, IC695CHS012, IC695CHS016)
- Power Consumption: Supplied via RX3i backplane
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Storage Temperature: -40°C to 85°C
- Humidity: 5% to 95% non-condensing
- Weight: Approx. 450 g
- Certifications: CE, UL, cUL
- Firmware: Configurable via Proficy Machine Edition (PME)
Key Features & Benefits
- Seamless PROFINET IO Integration: Acts as a PROFINET IO Controller, enabling the RX3i CPU to manage distributed IO devices over standard Ethernet infrastructure.
- High Device Capacity: Supports up to 128 PROFINET IO slave devices per scanner, reducing the need for multiple network segments.
- Dual-Port Integrated Switch: Built-in Ethernet switch supports line and ring topologies without additional hardware, simplifying network design.
- IRT & RT Support: Compatible with both Isochronous Real-Time (IRT) and Real-Time (RT) PROFINET communication classes for deterministic control.
- Hot-Swap Capable: Designed for RX3i backplane hot-swap, minimizing maintenance downtime in live systems.
- PME Configuration: Fully configurable through GE’s Proficy Machine Edition software with GSDML device import support.
- Diagnostic Transparency: Provides detailed device-level diagnostics accessible from the RX3i CPU for rapid fault isolation.
Industry & Equipment Applications
- Automotive Manufacturing: Body-in-white assembly lines, welding cells, and paint shop conveyors using PROFINET-enabled robots and drives.
- Food & Beverage: Hygienic filling, packaging, and conveyor systems with distributed PROFINET IO panels.
- Oil & Gas: Wellhead control panels and pipeline SCADA systems requiring deterministic Ethernet communication.
- Discrete Manufacturing: CNC machine tool integration, press lines, and assembly automation with Siemens or Phoenix Contact IO devices.
- Water & Wastewater: Pump station control and treatment plant automation with remote IO over PROFINET.
- Power Generation: Turbine control auxiliaries and substation automation requiring open Ethernet protocols.
System Integration & Compatible Parts
The IC695PNS001 is designed to operate within the GE PACSystems RX3i ecosystem. Key compatible components include:
- CPUs: IC695CPE302, IC695CPE305, IC695CPE310, IC695CPE330, IC695CPE400
- Backplanes: IC695CHS007 (7-slot), IC695CHS012 (12-slot), IC695CHS016 (16-slot)
- Power Supplies: IC695PSA040, IC695PSD040, IC695PSA140
- Ethernet Modules: IC695ETM001 (for additional Ethernet ports)
- PROFINET IO Devices: Compatible with any GSDML-certified PROFINET IO device (Siemens ET200, Phoenix Contact Axioline, Wago 750, etc.)
- Programming Software: Proficy Machine Edition (PME) v8.0 or later
Our Quality Assurance Process
At Konmask.com, every GE IC695PNS001 module undergoes a rigorous multi-stage verification process before shipment:
- Visual Inspection: Physical examination for damage, corrosion, counterfeit markings, and component integrity.
- Label & Traceability Verification: Cross-referencing part numbers, date codes, and serial numbers against GE’s official documentation.
- Functional Testing: Where applicable, modules are bench-tested in an RX3i rack environment to verify PROFINET communication and backplane interface.
- Anti-Static Packaging: All modules are shipped in ESD-safe bags with foam padding and double-box protection.
- Documentation: Certificate of conformance and test report available upon request.
How to Order
- Submit an inquiry via the “Get a Quote” button or email support@konmask.com.
- Provide your required quantity, delivery timeline, and destination country.
- Receive a formal quotation with lead time and shipping options within 24 business hours.
- Confirm the order and receive a proforma invoice for payment processing.
- Module ships with full tracking and insurance coverage.
Why Choose Konmask.com?
- ✅ Specialized in Industrial Automation: Focused exclusively on PLC, DCS, and automation hardware — not a generalist marketplace.
- ✅ Global B2B Export Experience: Serving engineering teams, MRO buyers, and system integrators across 40+ countries.
- ✅ Fast Sourcing for Obsolete & Hard-to-Find Parts: Extensive supplier network for discontinued GE modules.
- ✅ Technical Pre-Sales Support: Our team can advise on compatibility, firmware versions, and system configuration.
- ✅ Flexible Payment Terms: T/T, PayPal, and trade finance options available for qualified buyers.
- ✅ Secure Logistics: DHL, FedEx, and UPS express with full export documentation support.
Frequently Asked Questions
Q: Is the IC695PNS001 compatible with all PACSystems RX3i CPUs?
A: The IC695PNS001 is compatible with RX3i CPUs running firmware that supports PROFINET IO Controller functionality. This includes IC695CPE302, CPE305, CPE310, CPE330, and CPE400. Always verify firmware version compatibility in the GE PACSystems RX3i PROFINET IO Controller User Manual (GFK-2571).
Q: How many PROFINET IO devices can the IC695PNS001 support?
A: The module supports up to 128 PROFINET IO devices per scanner module. Multiple IC695PNS001 modules can be installed in the same RX3i backplane to expand capacity.
Q: Can I use the IC695PNS001 with third-party PROFINET IO devices?
A: Yes. The IC695PNS001 supports any GSDML-certified PROFINET IO device. Device configuration is performed by importing the GSDML file into Proficy Machine Edition.
Q: What is the lead time for the IC695PNS001?
A: Lead time varies by stock availability. In-stock units typically ship within 1–3 business days. For sourced units, lead time is 5–15 business days. Contact us for current availability.
Q: Do you provide a warranty on the IC695PNS001?
A: Yes. Konmask.com provides a 90-day functional warranty on all modules. Extended warranty options are available upon request.
Q: Can you supply multiple units for a plant-wide upgrade project?
A: Absolutely. We regularly fulfill bulk orders for system integrators and end-users. Volume pricing is available — please contact us with your project requirements.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691
{
“@context”: “https://schema.org”,
“@graph”: [
{
“@type”: “Product”,
“name”: “GE IC695PNS001 PACSystems RX3i PROFINET Scanner Module”,
“description”: “GE IC695PNS001 is a PROFINET IO Controller Scanner module for the PACSystems RX3i platform, supporting up to 128 PROFINET IO devices over standard Ethernet.”,
“sku”: “IC695PNS001”,
“mpn”: “IC695PNS001”,
“brand”: {
“@type”: “Brand”,
“name”: “GE”
},
“manufacturer”: {
“@type”: “Organization”,
“name”: “GE Automation & Controls”
},
“category”: “PROFINET Scanner Module”,
“url”: “https://konmask.com/products/ge-ic695pns001-pacsystems-rx3i-profinet-scanner-module”,
“offers”: {
“@type”: “Offer”,
“url”: “https://konmask.com/products/ge-ic695pns001-pacsystems-rx3i-profinet-scanner-module”,
“priceCurrency”: “USD”,
“availability”: “https://schema.org/InStock”,
“seller”: {
“@type”: “Organization”,
“name”: “Konmask.com”
}
}
},
{
“@type”: “FAQPage”,
“mainEntity”: [
{
“@type”: “Question”,
“name”: “Is the IC695PNS001 compatible with all PACSystems RX3i CPUs?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “The IC695PNS001 is compatible with RX3i CPUs running firmware that supports PROFINET IO Controller functionality, including IC695CPE302, CPE305, CPE310, CPE330, and CPE400.”
}
},
{
“@type”: “Question”,
“name”: “How many PROFINET IO devices can the IC695PNS001 support?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “The module supports up to 128 PROFINET IO devices per scanner module. Multiple IC695PNS001 modules can be installed in the same RX3i backplane.”
}
},
{
“@type”: “Question”,
“name”: “Can I use the IC695PNS001 with third-party PROFINET IO devices?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Yes. The IC695PNS001 supports any GSDML-certified PROFINET IO device. Configuration is performed by importing the GSDML file into Proficy Machine Edition.”
}
},
{
“@type”: “Question”,
“name”: “What is the lead time for the IC695PNS001?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “In-stock units typically ship within 1–3 business days. Sourced units have a lead time of 5–15 business days.”
}
},
{
“@type”: “Question”,
“name”: “Do you provide a warranty on the IC695PNS001?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Yes. Konmask.com provides a 90-day functional warranty on all modules. Extended warranty options are available upon request.”
}
}
]
}
]
}