Honeywell CC-PAON01 / CC-PAIN01 / CC-PDOB01 Analog & Digital I/O Module | Replacement, Equivalent & Selection Guide
The Honeywell CC-PAON01, CC-PAIN01, and CC-PDOB01 are high-performance I/O modules designed for the Honeywell Experion PKS distributed control system (DCS). These modules deliver precise analog output, analog input, and digital output capabilities for mission-critical industrial process control environments. At Konmask.com, we supply genuine and compatible replacement modules with full technical support for your selection and integration needs.
Technical Specifications
| Parameter | CC-PAON01 | CC-PAIN01 | CC-PDOB01 |
|---|---|---|---|
| Function | Analog Output | Analog Input | Digital Output |
| Series | Honeywell Experion PKS C300 / SCADA | ||
| Signal Range | 4–20 mA / 0–10 V | 4–20 mA / 0–10 V | 24 VDC Discrete |
| Channels | 8 AO Channels | 8 AI Channels | 16 DO Channels |
| Communication | FTE (Fault Tolerant Ethernet) / CEE Bus | ||
| Power Supply | 24 VDC (via backplane) | ||
| Operating Temp. | 0°C to 60°C | ||
| Certifications | CE, UL, FM, ATEX (zone 2) | ||
| Weight | ~200 g | ||
| Country of Origin | USA | ||
Compatible Replacement & Equivalent Models
When the original Honeywell module is unavailable or end-of-life, the following alternatives are commonly evaluated:
- CC-PAON01 (Analog Output) → Equivalent: Honeywell CC-PAON11, CC-PAON51; 3rd-party: Moore Industries SPA2, Pepperl+Fuchs KFD2-STC4-Ex1
- CC-PAIN01 (Analog Input) → Equivalent: Honeywell CC-PAIN11, CC-PAIN51; 3rd-party: Phoenix Contact MACX MCR-EX-SL-RPSSI-I
- CC-PDOB01 (Digital Output) → Equivalent: Honeywell CC-PDOB11, CC-PDOB51; 3rd-party: Weidmuller ACT20P-AI-AO-S
Note: Always verify firmware version and backplane compatibility before substitution. Contact support@konmask.com for a free compatibility check.
Why Choose the Original Model
- Seamless Integration — Plug-and-play with Honeywell Experion PKS C300 controllers; no re-engineering required.
- Certified Safety — FM, ATEX, and SIL-rated for use in hazardous process environments.
- Redundancy Support — Native support for redundant I/O configurations to maximize uptime.
- Long-term Support — Honeywell provides firmware updates and lifecycle support through authorized channels.
- Proven Reliability — Deployed globally in oil & gas, chemical, power, and water treatment plants.
Typical Applications
- Oil & Gas upstream/downstream process control (flow, pressure, temperature loops)
- Chemical plant DCS integration with HART-enabled field instruments
- Power generation turbine and boiler control systems
- Water & wastewater treatment SCADA systems
- Pharmaceutical batch process automation (FDA 21 CFR Part 11 environments)
- Pulp & paper mill continuous process control
System Compatibility
- DCS Platform: Honeywell Experion PKS R400 / R410 / R430 / R500+
- Controller: C300 Process Controller, ACE (Application Control Environment)
- Network: FTE (Fault Tolerant Ethernet), CEE backplane bus
- Software: Honeywell Control Builder, Experion Station HMI
- HART: HART 5 / HART 7 pass-through supported (CC-PAIN01)
Selection Guide
Use the table below to select the correct module for your application:
| Requirement | Recommended Model | Key Differentiator |
|---|---|---|
| Analog Output (4–20 mA) | CC-PAON01 | Standard 8-channel AO, non-redundant |
| Analog Output (redundant) | CC-PAON11 | Redundant pair configuration |
| Analog Input (4–20 mA / HART) | CC-PAIN01 | 8-channel AI with HART pass-through |
| Analog Input (redundant) | CC-PAIN11 | Redundant AI pair |
| Digital Output (24 VDC) | CC-PDOB01 | 16-channel DO, standard density |
| Digital Output (high density) | CC-PDOB11 | Redundant DO configuration |
Not sure which model fits your system? Send your existing I/O list or control narrative to support@konmask.com and our engineers will recommend the correct part within 24 hours.
Quality Assurance & Sourcing
- All modules are sourced from authorized distributors or verified surplus channels with full traceability.
- Each unit undergoes visual inspection, functional bench test, and firmware version verification before shipment.
- Packaging includes anti-static protection, original or equivalent documentation, and a 12-month warranty.
- Certificates of conformance (CoC) and test reports available upon request.
How to Order
- Confirm your Experion PKS release version (R400 / R430 / R500+) and controller type (C300 / ACE).
- Specify the exact part number: CC-PAON01, CC-PAIN01, or CC-PDOB01.
- Indicate required quantity and delivery timeline.
- Submit your inquiry via support@konmask.com or WhatsApp +0086 19859288691.
- Receive a formal quotation within 4 business hours with lead time and shipping options.
Replacement & Compatibility FAQ
Q: Can CC-PAON01 replace CC-PAON11 directly?
A: CC-PAON11 is the redundant version. CC-PAON01 can replace it in non-redundant configurations only. Backplane slot assignment must be verified.
Q: Is CC-PAIN01 compatible with HART 7 devices?
A: Yes, CC-PAIN01 supports HART 5 and HART 7 pass-through when used with Experion PKS R430 or later.
Q: What is the lead time for CC-PDOB01?
A: Standard stock items ship within 3–5 business days. For urgent requirements, contact us for expedited options.
Q: Do you supply modules with original Honeywell firmware?
A: Yes. All modules are supplied with factory-loaded firmware. Firmware upgrade support is available upon request.
Q: Can I use a 3rd-party equivalent in a SIL-rated loop?
A: Only if the replacement module carries equivalent SIL certification. We strongly recommend using original Honeywell modules for safety-instrumented systems.
© 2026 Konmask.com. All rights reserved.