Industrial Ethernet Switching Solution – Siemens 6GK5416-4GS00-2AM2 | SCALANCE X416
The Siemens SCALANCE X416 (6GK5416-4GS00-2AM2) is a managed Layer 2 industrial Ethernet switch engineered for mission-critical automation networks. With 16 Gigabit ports combining fiber and copper interfaces, it delivers deterministic, high-availability communication across harsh industrial environments — from substation automation to large-scale process control.
Where This Product Is Used
- Substation Automation (IEC 61850): Deployed as the backbone switch in digital substations, enabling GOOSE messaging and Sampled Values (SV) with sub-millisecond latency between IEDs, RTUs, and HMIs.
- Process Control & DCS Networks: Connects DCS controllers, field I/O, and engineering workstations in oil & gas, chemical, and refinery plants where network uptime is non-negotiable.
- Automotive Manufacturing Lines: Integrates PROFINET devices — robots, PLCs, and vision systems — across high-speed assembly lines requiring ring redundancy (MRP/MRPD).
- Water & Wastewater SCADA: Provides resilient Ethernet backbone for distributed pump stations and treatment facilities operating over extended fiber runs.
- Railway & Transportation Infrastructure: Supports EN 50155-compliant deployments in trackside control cabinets and rolling stock communication networks.
- Power Generation & Utilities: Used in turbine control rooms and grid-edge automation where IEEE 1588 PTP time synchronization is required for protection relay coordination.
Technical Specifications
- Part Number: 6GK5416-4GS00-2AM2
- Series: SCALANCE X-400 (X416)
- Switch Type: Managed Layer 2 Industrial Ethernet Switch
- Total Ports: 16 (configurable fiber + copper via media modules)
- Fiber Ports: 4× SFP Gigabit (100/1000 Mbps, LC duplex)
- Copper Ports: 12× RJ45 10/100/1000 Mbps (auto-negotiation, auto-crossover)
- Switching Capacity: Non-blocking, store-and-forward architecture
- Redundancy Protocols: MRP (Media Redundancy Protocol), RSTP, MSTP, HSR, PRP
- Time Synchronization: IEEE 1588v2 PTP (Boundary Clock / Transparent Clock), SNTP
- VLAN Support: IEEE 802.1Q, up to 4094 VLANs
- QoS: IEEE 802.1p, DSCP, 8 priority queues
- Management: Web UI, SNMP v1/v2c/v3, CLI (Telnet/SSH), PROFINET IO Device
- Power Supply: 24–60 V DC (redundant input), 100–240 V AC optional
- Operating Temperature: −40 °C to +70 °C
- Protection Rating: IP30 (panel mount)
- Dimensions (W×H×D): 60 × 125 × 124 mm (base unit)
- Weight: ~1,280 g
- Mounting: DIN rail / rack mount (with adapter)
- Certifications: CE, UL, cUL, ATEX Zone 2, IECEx, GL, DNV
Why Engineers Specify This Model
- IEC 61850 Edition 2 Certified: Native support for GOOSE, MMS, and SV makes it the preferred choice for protection and control engineers designing digital substations without additional gateways.
- Extreme Temperature Range (−40 °C to +70 °C): Operates reliably in outdoor cabinets, arctic environments, and high-heat process areas where commercial switches fail.
- Dual Redundant Power Inputs: Eliminates single points of failure; alarm relay output signals power loss to SCADA systems instantly.
- PROFINET IO Device Integration: Appears as a network node in TIA Portal, enabling diagnostics, port mirroring, and configuration directly from Siemens engineering tools — no separate NMS required.
- Modular Media Flexibility: Swap fiber/copper media modules without rewiring — future-proof for network topology changes.
- Cybersecurity Hardening: IEEE 802.1X port authentication, RADIUS, MAC-based access control, and HTTPS/SSH encryption align with IEC 62443-4-2 component security requirements.
Complete System Bill of Materials
For a complete IEC 61850 substation LAN or PROFINET ring, engineers typically pair the 6GK5416-4GS00-2AM2 with:
- 6GK5992-2AL00-8AA0 – SCALANCE X-400 24 V DC Power Supply Module
- 6GK5992-2GS00-8AA0 – SFP Transceiver 1000BASE-SX (850 nm, LC, 550 m)
- 6GK5992-2GX00-8AA0 – SFP Transceiver 1000BASE-LX (1310 nm, LC, 10 km)
- 6GK1901-1BB10-2AE0 – IE FC RJ45 Plug 180 (Industrial Ethernet connector)
- 6ES7315-2EH14-0AB0 – SIMATIC S7-300 CPU (upstream PLC controller)
- 6GK7343-1EX30-0XE0 – CP 343-1 PROFINET Communication Processor
Compliance & Industry Standards
- IEC 61850-3 (Communication networks for substations)
- IEEE 1613 (Environmental requirements for communication networking devices in electric power substations)
- IEC 62443-4-2 (Industrial cybersecurity component requirements)
- EN 50155 (Railway applications – electronic equipment)
- NEMA TS2 (Traffic management systems)
- UL 508 / UL 61010-1 (Industrial control equipment)
- ATEX II 3 G Ex nA IIC T4 Gc (Zone 2 hazardous area)
- DNV GL (Marine & offshore applications)
- RoHS 2011/65/EU compliant
Quality Assurance & Sourcing
Every Siemens 6GK5416-4GS00-2AM2 unit supplied by Konmask.com undergoes a rigorous intake process:
- ✔ Authenticity verification against Siemens serial number database
- ✔ Visual inspection for tamper evidence, counterfeit markings, and physical damage
- ✔ Functional power-on test with port link verification
- ✔ Original manufacturer packaging or anti-static ESD-safe repackaging
- ✔ Traceable chain of custody documentation available on request
We source from authorized Siemens distribution channels and vetted industrial surplus partners. All units carry a 12-month Konmask warranty against defects in materials and workmanship.
How to Source This Part
- In-Stock Orders: Add to cart and check out — ships within 1–3 business days from our warehouse.
- Bulk / Project Quantities: Contact support@konmask.com for volume pricing and lead-time commitments.
- Urgent / Emergency Procurement: Call or WhatsApp +0086 19859288691 for same-day quotation on critical plant shutdowns.
- Export & International Shipping: We ship worldwide with full export documentation (commercial invoice, packing list, COO). DDP and DAP Incoterms available.
- Repair & Exchange: Advance exchange program available — contact us with your failed unit details.
Application-Specific FAQ
Q: Can the 6GK5416-4GS00-2AM2 be used as a PRP/HSR node for IEC 61850 protection applications?
A: Yes. The SCALANCE X416 supports both PRP (Parallel Redundancy Protocol) and HSR (High-availability Seamless Redundancy) per IEC 62439-3, achieving zero-switchover-time redundancy required for protection relay applications.
Q: Is this switch compatible with Siemens TIA Portal for PROFINET diagnostics?
A: Yes. The X416 is a PROFINET IO Device and can be integrated into TIA Portal V14 and later. Port status, link speed, and alarm conditions are visible directly in the network view.
Q: What fiber transceivers are compatible with the SFP slots?
A: Siemens-branded SFPs (6GK5992-2GS00-8AA0 for SX, 6GK5992-2GX00-8AA0 for LX) are recommended. Third-party SFPs may work but are not officially supported and may trigger SNMP alarms.
Q: Does this unit support IEEE 1588 PTP for time-sensitive protection applications?
A: Yes. The 6GK5416-4GS00-2AM2 supports IEEE 1588v2 as both Boundary Clock and Transparent Clock, enabling sub-microsecond time synchronization across the substation LAN.
Q: What is the difference between 6GK5416-4GS00-2AM2 and 6GK5416-4GS00-2AM2 variants?
A: The suffix -2AM2 denotes the standard managed version with AC/DC power supply flexibility. Always verify the full order number with your Siemens representative or Konmask.com to ensure the correct power supply and media module configuration for your project.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691