When a power monitoring control module fails on the plant floor, the consequences cascade instantly: energy data goes dark, demand management algorithms lose their reference point, and maintenance teams are left flying blind during peak load events. In facilities where power quality directly impacts production yield — semiconductor fabs, pharmaceutical cleanrooms, continuous-process chemical plants — even a brief gap in monitoring can translate to unplanned downtime, regulatory non-compliance, or costly demand-charge spikes. The Allen-Bradley 1407-CGCM Control Module is the precision instrument that prevents this scenario, serving as the intelligent core of the PowerMonitor 3000 system.
Within the PowerMonitor 3000 family, the 1407-CGCM occupies the role of the central gateway module — the component that aggregates metered data from current and voltage inputs, executes real-time power calculations, and exposes that data to upstream control systems via standard industrial communication protocols. Rockwell Automation’s PowerMonitor 3000 platform is deployed across thousands of industrial facilities worldwide, trusted by energy managers and plant engineers who require IEC-compliant power quality analysis without sacrificing integration simplicity. The 1407-CGCM is the module that makes that trust possible.
Technical Specifications
- Part Number: 1407-CGCM
- Series: PowerMonitor 3000
- Manufacturer: Allen-Bradley / Rockwell Automation
- Module Type: Control Gateway / Communication Module
- Communication Interface: Compatible with DH-485, DeviceNet, and ControlNet (per system configuration)
- Mounting: DIN rail / panel mount per PowerMonitor 3000 chassis
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Storage Temperature: -40°C to 85°C
- Enclosure Rating: IP20 (panel-mount installation)
- Power Supply: Supplied via PowerMonitor 3000 backplane
- Certifications: UL Listed, CE Marked, RoHS Compliant
- Weight: Approx. 60 g
Note: Specifications are based on published Rockwell Automation documentation. Always verify against the official product manual (Publication 1407-UM001) for your specific application.
Key Features & Benefits
- Real-Time Power Calculation Engine: Continuously computes true RMS voltage, current, active power (kW), reactive power (kVAR), apparent power (kVA), and power factor — giving energy managers the granular data needed for demand response programs.
- Seamless Rockwell Ecosystem Integration: Designed to communicate natively with Allen-Bradley PLCs and SCADA systems, eliminating the need for protocol converters or custom middleware.
- Energy Data Logging: Supports interval-based energy accumulation, enabling time-of-use analysis and utility billing verification.
- Compact Form Factor: Fits within the standard PowerMonitor 3000 chassis, preserving panel space in congested electrical enclosures.
- Robust Industrial Design: Built to withstand the electrical noise, vibration, and temperature cycling common in heavy industrial environments.
- Simplified Commissioning: Module-level configuration via RSPower or Studio 5000 Logix Designer reduces setup time for qualified integrators.
Industry & Equipment Applications
- Oil & Gas: Substation and MCC power monitoring for upstream and midstream facilities
- Automotive Manufacturing: Press line and paint shop energy management
- Water & Wastewater: Pump station demand monitoring and utility cost allocation
- Food & Beverage: Clean-in-place (CIP) system energy auditing
- Mining & Minerals: Crusher and conveyor drive power quality analysis
- Data Centers: UPS and PDU monitoring for PUE optimization
- Pharmaceutical: GMP-compliant energy data acquisition for regulated environments
System Integration & Compatible Parts
The 1407-CGCM is designed to operate within the Allen-Bradley PowerMonitor 3000 platform. Typical system configurations include:
- 1407-CGCM — Control Gateway Module (this item)
- 1407-CGBM — Base Module (chassis foundation)
- 1407-CGM2 — Metering Module (voltage/current inputs)
- 1407-CGPM — Power Supply Module
- 1756-ENBT / 1756-EN2T — ControlLogix Ethernet Bridge (for upstream PLC integration)
- RSPower 32 / Studio 5000 — Configuration and monitoring software
Contact our technical team to confirm compatibility with your existing PowerMonitor 3000 chassis revision and firmware version before ordering.
Our Quality Assurance Process
Every Allen-Bradley 1407-CGCM sourced through Konmask.com undergoes a structured verification process before shipment:
- Authenticity Verification: Visual inspection of Rockwell Automation holographic labels, date codes, and country-of-origin markings against known-good references.
- Packaging Integrity Check: Original factory packaging or equivalent ESD-safe repackaging confirmed prior to dispatch.
- Documentation Review: Certificate of conformance and traceability records available upon request for regulated industries.
- Functional Pre-Check (where applicable): Modules sourced from verified surplus channels are bench-tested for power-on response before listing.
How to Order
- Submit an inquiry via the Contact Us form or email support@konmask.com with your required quantity and delivery timeline.
- Our technical sales team will confirm availability, lead time, and provide a formal quotation within 1 business day.
- Upon PO receipt, we arrange shipment via DHL, FedEx, or UPS with full tracking and export documentation.
- For urgent requirements, expedited sourcing and same-day dispatch options are available — please indicate in your inquiry.
Why Choose Konmask.com?
- Industrial Automation Specialists: We focus exclusively on PLC, DCS, and power monitoring components — not a generalist distributor.
- Global Sourcing Network: Access to verified surplus, authorized distribution channels, and factory-new stock across North America, Europe, and Asia.
- Technical Pre-Sales Support: Our engineers can assist with cross-referencing, compatibility confirmation, and system-level questions before you commit to a purchase.
- Fast International Shipping: Consolidated export experience with customs documentation support for buyers in China, Southeast Asia, the Middle East, and beyond.
- Transparent Traceability: Full documentation chain available for quality-critical procurement teams.
Frequently Asked Questions
Q: Is the 1407-CGCM still in production by Rockwell Automation?
A: The PowerMonitor 3000 series has reached end-of-life status with Rockwell Automation. However, the 1407-CGCM remains widely available through authorized surplus channels. Konmask.com maintains stock sourced from verified industrial decommissions and authorized distributors. Contact us for current availability.
Q: Can the 1407-CGCM be used as a direct replacement in an existing PowerMonitor 3000 system?
A: Yes, provided the chassis revision and firmware are compatible. We recommend confirming the existing system’s catalog number suffix and firmware revision with our technical team before ordering to ensure a drop-in replacement.
Q: What communication protocols does the 1407-CGCM support?
A: The 1407-CGCM supports communication via the PowerMonitor 3000 backplane to connected network adapter modules. Supported upstream protocols depend on the network module installed (e.g., DH-485, DeviceNet, ControlNet). Please refer to publication 1407-UM001 for the full protocol matrix.
Q: Do you provide a warranty on the 1407-CGCM?
A: Yes. All modules sold through Konmask.com carry a minimum 90-day functional warranty. Extended warranty options are available — please inquire at the time of quotation.
Q: Can you supply multiple units for a plant-wide retrofit project?
A: Absolutely. We regularly fulfill multi-unit orders for MRO and capital project procurement teams. Volume pricing is available — please include your required quantity in your inquiry for a tailored quotation.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691
{
“@context”: “https://schema.org”,
“@graph”: [
{
“@type”: “Product”,
“name”: “Allen-Bradley 1407-CGCM Control Module”,
“description”: “Allen-Bradley 1407-CGCM Control Module for PowerMonitor 3000 Series. Industrial power monitoring gateway module for real-time energy data acquisition and PLC integration.”,
“sku”: “1407-CGCM”,
“mpn”: “1407-CGCM”,
“brand”: {
“@type”: “Brand”,
“name”: “Allen-Bradley”
},
“manufacturer”: {
“@type”: “Organization”,
“name”: “Rockwell Automation”
},
“category”: “Industrial Control Module / Power Monitoring”,
“url”: “https://konmask.com/products/allen-bradley-1407-cgcm-control-module-powermonitor-3000”,
“offers”: {
“@type”: “Offer”,
“priceCurrency”: “USD”,
“availability”: “https://schema.org/InStock”,
“seller”: {
“@type”: “Organization”,
“name”: “Konmask.com”,
“url”: “https://konmask.com”
}
}
},
{
“@type”: “FAQPage”,
“mainEntity”: [
{
“@type”: “Question”,
“name”: “Is the 1407-CGCM still in production by Rockwell Automation?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “The PowerMonitor 3000 series has reached end-of-life status with Rockwell Automation. However, the 1407-CGCM remains widely available through authorized surplus channels. Konmask.com maintains stock sourced from verified industrial decommissions and authorized distributors.”
}
},
{
“@type”: “Question”,
“name”: “Can the 1407-CGCM be used as a direct replacement in an existing PowerMonitor 3000 system?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Yes, provided the chassis revision and firmware are compatible. We recommend confirming the existing system’s catalog number suffix and firmware revision with our technical team before ordering.”
}
},
{
“@type”: “Question”,
“name”: “What communication protocols does the 1407-CGCM support?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “The 1407-CGCM supports communication via the PowerMonitor 3000 backplane to connected network adapter modules. Supported upstream protocols depend on the network module installed (e.g., DH-485, DeviceNet, ControlNet).”
}
},
{
“@type”: “Question”,
“name”: “Do you provide a warranty on the 1407-CGCM?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “Yes. All modules sold through Konmask.com carry a minimum 90-day functional warranty. Extended warranty options are available upon request.”
}
},
{
“@type”: “Question”,
“name”: “Can you supply multiple units for a plant-wide retrofit project?”,
“acceptedAnswer”: {