BACHMANN MX213 – High-Performance Redundant Processor Module | MC200 Series Platform
Engineering Background
The BACHMANN MX213 is a central processing unit (CPU) module designed for the BACHMANN MC200 modular automation platform. Engineered for demanding industrial environments, the MX213 delivers deterministic real-time control with support for hot-standby redundancy, making it a preferred choice for critical infrastructure, power generation, and process automation applications where unplanned downtime carries significant operational and financial consequences.
Product Positioning
The MX213 occupies the mid-to-high tier of the BACHMANN MC200 CPU lineup, offering a balance of processing throughput, I/O scalability, and communication flexibility. It is the go-to module for system integrators and OEMs who require IEC 61131-3 compliant programming, high-speed cycle times, and seamless integration with BACHMANN’s distributed I/O and drive ecosystems. Konmask.com stocks verified-authentic MX213 units sourced through authorized distribution channels, with full traceability documentation available on request.
Complete Technical Specifications
| Part Number | MX213 |
| Manufacturer | BACHMANN electronic GmbH |
| Platform | MC200 Modular Automation System |
| Module Type | Central Processor Unit (CPU) |
| Programming Standard | IEC 61131-3 (LD, FBD, ST, IL, SFC) |
| Redundancy Support | Hot-standby CPU redundancy |
| Cycle Time | Configurable; deterministic real-time execution |
| Communication Interfaces | Ethernet (100 Mbit/s), PROFIBUS DP, CANopen (via expansion) |
| Onboard Memory | Program memory + retain data memory (battery-backed) |
| Operating Voltage | 24 V DC (via backplane) |
| Operating Temperature | 0 °C to +55 °C |
| Storage Temperature | -25 °C to +70 °C |
| Relative Humidity | 5 % to 95 % (non-condensing) |
| Protection Class | IP20 |
| Weight | approx. 600 g |
| Certifications | CE, UL (refer to current BACHMANN datasheet for full listing) |
| Firmware | Upgradeable via BACHMANN SolutionCenter |
Note: Specifications are based on published BACHMANN documentation. Always verify against the official MX213 datasheet for your specific firmware revision before final engineering sign-off.
Proven Application Environments
- Wind & Solar Power Generation – Real-time turbine and inverter control with redundant failover
- Oil & Gas Processing – Safety-critical process automation with deterministic scan cycles
- Water & Wastewater Treatment – Continuous process monitoring and SCADA integration
- Industrial Machinery & OEM Equipment – High-speed motion sequencing and multi-axis coordination
- Building Automation & Infrastructure – BACnet/Modbus gateway applications via MC200 communication modules
- Marine & Offshore Systems – Vibration-tolerant, wide-temperature operation in harsh environments
Engineering Advantages
- Hot-Standby Redundancy – Seamless CPU switchover with no process interruption; ideal for 24/7 continuous operations
- IEC 61131-3 Compliance – Full multi-language programming support reduces engineering ramp-up time and enables code reuse across projects
- Modular Scalability – Expands within the MC200 rack system; mix digital, analog, and specialty I/O modules without CPU replacement
- Deterministic Execution – Guaranteed cycle-time consistency critical for closed-loop control and safety interlocks
- Integrated Diagnostics – Onboard LED status indicators and software-accessible fault registers accelerate commissioning and troubleshooting
- Long Product Lifecycle – BACHMANN’s industrial-grade components are designed for 10+ year operational lifespans with sustained spare-parts availability
System Architecture & Signal Flow
The MX213 mounts directly into the MC200 backplane rack, communicating with I/O modules via the high-speed internal bus. In a redundant configuration, two MX213 units operate in a primary/standby topology: the primary CPU executes the control program and continuously synchronizes process image data to the standby unit. Upon detection of a primary fault, the standby assumes control within the configured switchover time, preserving all retain variables and output states.
External engineering workstations connect via Ethernet using BACHMANN SolutionCenter IDE for program download, online monitoring, and firmware management. Field devices interface through the MC200’s distributed I/O modules or via fieldbus masters (PROFIBUS DP, CANopen) hosted on dedicated communication modules within the same rack.
Sourcing & Quality Verification
- Authenticity – All MX213 units listed on Konmask.com are sourced from verified supply chains. Counterfeit risk is mitigated through supplier qualification and incoming inspection.
- Condition – Units are available as new/surplus-new. Condition grade is clearly stated on each listing. Refurbished units, where offered, include full functional test reports.
- Traceability – Date codes, firmware versions, and serial number ranges are documented and available upon request for critical procurement.
- Packaging – ESD-safe packaging with anti-static bags and foam inserts. Export cartons rated for international air and sea freight.
Procurement Process
- Step 1 – RFQ Submission: Contact [email protected] with your required quantity, target delivery date, and any firmware/revision requirements.
- Step 2 – Quotation & Lead Time: Receive a formal quotation within 1 business day including unit price, shipping options, and estimated lead time.
- Step 3 – Order Confirmation: Submit purchase order. Payment terms: T/T, PayPal, or as agreed for qualified accounts.
- Step 4 – Inspection & Dispatch: Units undergo pre-shipment inspection. Tracking number provided within 24 hours of dispatch.
- Step 5 – After-Sales Support: Technical support available via email and phone. Warranty claims processed within 5 business days.
Technical FAQ
Q: Is the MX213 compatible with older MC200 racks?
A: Yes. The MX213 is backward-compatible with standard MC200 backplane racks. Verify rack revision and power supply capacity before installation.
Q: Can the MX213 run without a redundant partner?
A: Yes. The MX213 operates as a standalone CPU. Redundancy is an optional configuration activated via software licensing and a second MX213 unit.
Q: What programming software is required?
A: BACHMANN SolutionCenter (based on CODESYS) is required for program development, download, and diagnostics. Contact BACHMANN or Konmask for licensing guidance.
Q: What is the typical lead time for MX213 from Konmask?
A: In-stock units ship within 3–5 business days internationally. For urgent requirements, DHL Express options are available.
Q: Does Konmask provide a warranty?
A: Yes. A 12-month warranty against manufacturing defects is provided on all new units. Terms available on request.