Engineering Background
The IC695PBM300 is GE’s dedicated PROFIBUS DP Master module engineered for the PACSystems RX3i universal backplane architecture. Designed to bridge high-speed RX3i backplane communications with field-level PROFIBUS DP networks, this module enables deterministic, high-integrity data exchange between the RX3i CPU and up to 125 PROFIBUS DP slave devices — making it the backbone of distributed I/O and intelligent field device integration in process and discrete manufacturing environments.
Product Positioning
Targeted at automation engineers requiring a robust, standards-compliant PROFIBUS DP master in a PACSystems RX3i chassis, the IC695PBM300 eliminates the need for external gateways and delivers native backplane-speed integration. It is the preferred choice for brownfield upgrades, greenfield DCS/PLC hybrid architectures, and any application demanding IEC 61158-compliant fieldbus performance within the GE PACSystems ecosystem.
Complete Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | IC695PBM300 |
| Platform | GE PACSystems RX3i |
| Module Type | PROFIBUS DP Master (Class 1) |
| Protocol | PROFIBUS DP-V0 / DP-V1 |
| Max Slave Devices | 125 per master |
| Max Input Data | 244 bytes per scan |
| Max Output Data | 244 bytes per scan |
| Baud Rates | 9.6 kbps – 12 Mbps (auto-detect) |
| Physical Interface | 9-pin D-sub (RS-485) |
| Backplane Interface | RX3i Universal Backplane |
| Configuration Tool | Proficy Machine Edition (PME) |
| Power Consumption | Supplied via RX3i backplane |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | -40 °C to +85 °C |
| Relative Humidity | 5% – 95% non-condensing |
| Certifications | CE, UL, cUL |
| Form Factor | Single-slot RX3i module |
| Weight | ~1,000 g (module + packaging) |
Proven Application Environments
- Discrete Manufacturing: Automotive assembly lines integrating PROFIBUS-enabled servo drives, VFDs, and distributed I/O racks
- Process Industries: Chemical, oil & gas, and water treatment plants using PROFIBUS DP for valve positioners and field transmitters
- Power Generation: Turbine control and substation automation with deterministic fieldbus scan cycles
- Material Handling: Conveyor and sortation systems with distributed motor starters and safety modules on PROFIBUS
- Brownfield Upgrades: Replacing legacy PROFIBUS masters while retaining existing field wiring and slave device configurations
- Hybrid DCS/PLC Architectures: PACSystems RX3i acting as PROFIBUS master alongside DCS supervisory layers
Engineering Advantages
- Native Backplane Integration: Direct RX3i backplane communication eliminates gateway latency and single points of failure
- DP-V1 Acyclic Services: Supports parameterization and diagnostics of intelligent field devices without interrupting cyclic I/O
- Auto Baud Rate Detection: Simplifies commissioning across mixed-speed PROFIBUS segments
- GSD File Compatibility: Full support for standard GSD/GSDML device description files in Proficy Machine Edition
- Diagnostic Transparency: Module-level and slave-level diagnostics surfaced directly in the RX3i CPU fault table
- Hot-Swap Capable: Supports RX3i hot-swap procedures for minimal process downtime during module replacement
- Scalable Architecture: Multiple IC695PBM300 modules can be installed in a single RX3i chassis for expanded slave capacity
System Architecture & Signal Flow
The IC695PBM300 occupies a single slot in the RX3i universal backplane and communicates with the RX3i CPU (e.g., IC695CPE305, IC695CPE400) via the high-speed backplane bus. On the field side, the module’s 9-pin D-sub RS-485 port connects to the PROFIBUS DP segment. The CPU’s application program reads and writes I/O data to the module’s backplane-mapped memory, which the IC695PBM300 cyclically exchanges with up to 125 DP slaves. DP-V1 acyclic read/write services are handled via dedicated message channels, enabling parameterization and diagnostics without disrupting cyclic I/O. Configuration is performed offline in Proficy Machine Edition using imported GSD files, then downloaded to the module via the CPU.
Typical signal flow: RX3i CPU ↔ Backplane Bus ↔ IC695PBM300 ↔ RS-485 PROFIBUS DP Segment ↔ Slave Devices (I/O, Drives, Instruments)
Sourcing & Quality Verification
- Origin: Sourced from authorized GE/Emerson distribution channels and verified surplus with full traceability
- Inspection: Each unit undergoes visual inspection, label verification, and functional power-on testing prior to shipment
- Authenticity: Part numbers, date codes, and firmware revision labels verified against GE factory documentation
- Packaging: Anti-static ESD packaging with moisture barrier; original GE packaging retained where available
- Warranty: 12-month Konmask operational warranty covering manufacturing defects and functional failures
- Documentation: GE datasheet, installation guide, and PME configuration reference available upon request
Procurement Process
- Step 1 — Inquiry: Submit your RFQ via the product page or email support@konmask.com with quantity and required delivery date
- Step 2 — Quote: Receive a formal quotation with unit price, lead time, and shipping options within 1 business day
- Step 3 — Order Confirmation: Purchase order accepted via Shopify checkout, bank transfer (T/T), or agreed trade terms
- Step 4 — Pre-Shipment Inspection: Final QC check and photo documentation provided before dispatch
- Step 5 — Shipping: DHL / FedEx / UPS express with full tracking; sea freight available for bulk orders
- Step 6 — After-Sales: Technical support, commissioning guidance, and warranty claims handled by Konmask engineering team
Technical FAQ
Q: Is the IC695PBM300 compatible with all RX3i CPUs?
A: Yes. It is compatible with all PACSystems RX3i CPUs (IC695CPE302, CPE305, CPE310, CPE400, etc.) installed in the RX3i universal backplane.
Q: Can I use multiple IC695PBM300 modules in one chassis?
A: Yes. Multiple modules can be installed in a single RX3i chassis, each managing an independent PROFIBUS DP segment with up to 125 slaves per module.
Q: Does it support PROFIBUS DP-V1 acyclic services?
A: Yes. The IC695PBM300 supports both DP-V0 cyclic I/O and DP-V1 acyclic read/write for device parameterization and diagnostics.
Q: What configuration software is required?
A: Proficy Machine Edition (PME) is required for hardware configuration, GSD file import, and slave address assignment. No additional third-party tools are needed.
Q: What is the maximum PROFIBUS segment length?
A: Segment length depends on baud rate — up to 1,200 m at 93.75 kbps, reducing to 100 m at 12 Mbps. Repeaters can extend total network reach.
Q: Is firmware upgrade supported in the field?
A: Firmware updates are performed via Proficy Machine Edition connected to the RX3i CPU. Contact Konmask for the latest firmware revision applicable to your system.
Q: Do you provide a test report or functional verification certificate?
A: Yes. A pre-shipment functional test report is available upon request for all orders.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691