Honeywell K2LCN-8 (51401551-801) Local Control Network Module | Replacement, Equivalent & Selection Guide
The Honeywell K2LCN-8 (Part No. 51401551-801) is a Local Control Network (LCN) communication module designed for use in Honeywell’s TDC 3000 Distributed Control System (DCS). It provides high-speed peer-to-peer data exchange between process controllers, operator stations, and application modules across the LCN highway. Konmask.com supplies genuine and compatible-grade K2LCN-8 modules with full traceability for industrial automation environments.
Technical Specifications
- Manufacturer: Honeywell Process Solutions
- Part Number: K2LCN-8 / 51401551-801
- Module Type: Local Control Network (LCN) Interface Module
- Series: TDC 3000 / PlantScape / Experion PKS (legacy LCN)
- Network: LCN Highway (Local Control Network)
- Data Rate: 5 Mbps (LCN standard)
- Form Factor: Card/module for TDC 3000 cabinet
- Power Supply: Supplied via backplane
- Operating Temperature: 0°C to 60°C
- Weight: Approx. 1 kg
- Condition Available: New, Refurbished, Tested
Compatible Replacement & Equivalent Models
When the K2LCN-8 is discontinued or unavailable, the following models may serve as functional equivalents or drop-in replacements depending on your system revision:
- 51401551-100 – Earlier revision of the same LCN module family; verify firmware compatibility
- 51401551-200 – Mid-series revision; compatible with most TDC 3000 R500+ systems
- 51401551-400 – Upgraded variant with enhanced diagnostics; backward compatible
- K2LCN-4 (51401551-701) – 4-node variant; suitable for smaller LCN segments
- LCNP4E – Enhanced LCN processor; used in Experion PKS migration paths
- Note: Always verify hardware revision, firmware version, and cabinet slot compatibility before substitution. Contact Konmask for cross-reference validation.
Why Choose the Original K2LCN-8 (51401551-801)
- Factory-validated for TDC 3000 LCN highway communication integrity
- Proven reliability in continuous-process industries (refining, petrochemical, power)
- Full backward compatibility with existing TDC 3000 cabinet infrastructure
- Supported by Honeywell’s legacy spare parts program and Konmask’s sourcing network
- Reduces integration risk compared to third-party or non-OEM alternatives
Typical Applications
- Oil & gas refinery DCS control loops
- Chemical and petrochemical plant automation
- Power generation and utilities control systems
- Pulp & paper process control
- Pharmaceutical batch control (TDC 3000 legacy installations)
- LCN highway expansion and node replacement projects
System Compatibility
- Honeywell TDC 3000 – Primary target platform (R400 and above recommended)
- Honeywell PlantScape – Compatible via LCN gateway configurations
- Honeywell Experion PKS – Supported in legacy LCN coexistence mode
- Cabinet Types: Universal Control Network (UCN) cabinets with LCN backplane
- Not compatible with: Experion LS, C300 controller series, or non-LCN Honeywell platforms
Selection Guide
Use the following criteria to confirm the K2LCN-8 is the right module for your application:
- Step 1 – Confirm platform: Verify your DCS is TDC 3000 or a compatible LCN-based system.
- Step 2 – Check node count: K2LCN-8 supports up to 8 LCN nodes; use K2LCN-4 for smaller segments.
- Step 3 – Verify part suffix: Suffix -801 denotes the latest production revision; confirm against your system BOM.
- Step 4 – Firmware alignment: Match module firmware to your system software release (R500, R510, R520, etc.).
- Step 5 – Slot availability: Confirm physical slot and backplane pin compatibility in your cabinet.
- Need help? Send your system BOM or cabinet drawing to support@konmask.com for a free compatibility check.
Quality Assurance & Sourcing
- All K2LCN-8 modules sourced through authorized industrial distributors and verified supply chains
- Each unit undergoes visual inspection, functional bench test, and ESD-safe packaging
- Certificates of conformance and test reports available upon request
- Traceability documentation provided for regulated industries
- Konmask.com maintains stock of both new and refurbished units to support urgent MRO needs
How to Order
- Online: Add to cart directly from this page
- Email RFQ: support@konmask.com – include quantity, required condition (new/refurbished), and delivery timeline
- Phone/WhatsApp: +0086 19859288691
- Lead Time: In-stock units ship within 1–3 business days; sourced units 5–15 business days
- Payment: T/T, PayPal, credit card, and trade terms available for qualified accounts
Replacement & Compatibility FAQ
Q: Can the K2LCN-8 replace the 51401551-400 directly?
A: In most TDC 3000 R500+ systems, yes. The -801 suffix is the latest revision and is backward compatible with -400 and -200 variants. Firmware verification is recommended.
Q: Is the K2LCN-8 compatible with Experion PKS C300 controllers?
A: No. The K2LCN-8 is an LCN-bus module and is not compatible with the C300 series, which uses a different communication architecture (FTE/FOUNDATION Fieldbus).
Q: Do you supply refurbished units with warranty?
A: Yes. Konmask offers refurbished K2LCN-8 modules with a 90-day functional warranty and full test documentation.
Q: How do I verify the correct revision for my system?
A: Check your system’s hardware BOM or contact Honeywell support for the recommended spare part revision. Konmask’s technical team can also assist — email us your system details.
Q: Can I get a datasheet or wiring diagram?
A: Yes. Contact support@konmask.com and we will provide available technical documentation.
© 2026 Konmask.com. All rights reserved.