DeviceNet Automation Solution – YOKOGAWA F3LD01-ON | FA-M3 Series
The YOKOGAWA F3LD01-ON is a high-performance DeviceNet Scanner Module designed for the FA-M3 modular PLC platform. It enables seamless integration of DeviceNet field devices — including drives, sensors, and actuators — into centralized control architectures across demanding industrial environments.
Where This Product Is Used
The F3LD01-ON is specified by automation engineers in applications where reliable, deterministic DeviceNet communication is critical:
- Automotive Assembly Lines — Coordinating robot controllers, servo drives, and safety PLCs over a single DeviceNet trunk
- Food & Beverage Processing — Connecting distributed I/O blocks, variable frequency drives (VFDs), and conveyor sensors in hygienic production lines
- Pharmaceutical Manufacturing — Integrating smart actuators and flow meters in GMP-compliant batch control systems
- Water & Wastewater Treatment — Monitoring pump stations and valve positioners across large-scale SCADA networks
- Semiconductor Fabrication — Linking precision motion controllers and environmental sensors in cleanroom automation
- Pulp & Paper Mills — Managing distributed drives and tension controllers on high-speed winding machines
Technical Specifications
| Part Number | F3LD01-ON |
| Manufacturer | YOKOGAWA Electric Corporation |
| Series | FA-M3 (STARDOM / Sequence CPU Compatible) |
| Module Type | DeviceNet Master / Scanner Module |
| Network Protocol | DeviceNet (CAN-based, IEC 62026-3) |
| Max Slave Nodes | 63 nodes per network |
| I/O Data Size | Up to 256 bytes input / 256 bytes output |
| Baud Rates | 125 kbps / 250 kbps / 500 kbps |
| Power Consumption | 5 VDC from backplane bus |
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -20°C to +70°C |
| Humidity | 10% to 90% RH (non-condensing) |
| Weight | Approx. 213 g |
| Mounting | FA-M3 base unit slot (standard module pitch) |
| Certifications | CE, UL, ODVA Conformance Tested |
Why Engineers Specify This Model
- Native FA-M3 Integration — Plug-and-play compatibility with YOKOGAWA FA-M3 CPU modules; no external gateway required
- ODVA-Certified Interoperability — Guaranteed compatibility with third-party DeviceNet slaves from Allen-Bradley, Omron, Turck, and others
- Deterministic Scan Cycle — Polled, change-of-state (COS), and cyclic messaging modes ensure predictable network latency
- Flexible Topology — Supports trunk-line/drop-line topology with T-port taps; compatible with thick and thin cable media
- Diagnostic Transparency — Per-node status flags and network health LEDs simplify commissioning and fault isolation
- Long Product Lifecycle — YOKOGAWA FA-M3 platform is actively supported with firmware updates and spare parts availability
Complete System Bill of Materials
For a complete FA-M3 DeviceNet control node, engineers typically specify:
- FA-M3 CPU Module (e.g., F3SP71-4N, F3SP76-7N)
- F3LD01-ON — DeviceNet Scanner Module (this item)
- FA-M3 Base Unit (e.g., F3BU04-0N, F3BU16-0N)
- FA-M3 Power Supply Module (e.g., F3PU20-0S)
- DeviceNet Trunk Cable (thick: 7841A, thin: 1485C-P1-C300)
- DeviceNet Power Supply (24 VDC, min. 4 A for network)
- ODVA-compliant T-port taps and terminating resistors (121 Ω)
Compliance & Industry Standards
- DeviceNet: ODVA DeviceNet Specification, Volume I & II
- IEC 62026-3: Low-voltage switchgear and controlgear — DeviceNet
- CE Marking: EMC Directive 2014/30/EU; Low Voltage Directive 2014/35/EU
- UL Listed: UL 508 (Industrial Control Equipment)
- RoHS Compliant: Directive 2011/65/EU
Quality Assurance & Sourcing
Every YOKOGAWA F3LD01-ON unit shipped by Konmask.com undergoes the following verification process:
- Visual inspection against YOKOGAWA OEM packaging and label standards
- Serial number traceability check against manufacturer records
- Functional power-on test prior to dispatch
- Anti-static packaging with humidity indicator card
- Sourced from authorized distributors and verified surplus channels — no counterfeit risk
How to Source This Part
Konmask.com maintains ready stock of the F3LD01-ON for immediate dispatch. For volume orders, OEM replacement programs, or system integration projects:
- 📧 Email: [email protected]
- 📞 Phone / WhatsApp: +0086 19859288691
- 🌐 Web: https://konmask.com
- Lead time: In-stock items ship within 1–3 business days; DHL / FedEx / UPS international express available
Application-Specific FAQ
Q: Can the F3LD01-ON operate as a DeviceNet slave instead of a master?
A: No. The F3LD01-ON is a master/scanner module only. For slave functionality, refer to YOKOGAWA’s F3LD02 or equivalent slave adapter modules.
Q: How many F3LD01-ON modules can be installed in one FA-M3 base unit?
A: Up to the slot capacity of the base unit (max. 16 I/O slots on F3BU16-0N). Multiple scanner modules can coexist, each managing an independent DeviceNet segment.
Q: Is the F3LD01-ON compatible with EtherNet/IP or PROFIBUS networks?
A: No. This module is exclusively for DeviceNet. For EtherNet/IP, specify the F3LE01-5T; for PROFIBUS-DP, specify the F3LP02-0N.
Q: What programming software is required for configuration?
A: YOKOGAWA ToolBox (WideField3) is used for FA-M3 CPU programming. DeviceNet network configuration is performed via the module’s EDS file loaded into any ODVA-compliant network configuration tool (e.g., RSNetWorx for DeviceNet).
Q: Can this module be used in a hot-standby redundant CPU configuration?
A: Yes, when paired with YOKOGAWA’s FA-M3 dual-CPU redundancy option. Consult the F3LD01-ON hardware manual (IM 34M06H62-01E) for redundancy wiring and configuration details.