Industrial Network Integration Solution – ABB FEIP-21 | ACS880 Drive Series
Where This Product Is Used
The ABB FEIP-21 EtherNet/IP Adapter Module (3AXD50000192793) is deployed in demanding industrial automation environments where ACS880 variable frequency drives must communicate over EtherNet/IP networks. Typical application sites include:
- Automotive Assembly Lines – Synchronizing conveyor belt drives with PLC-controlled robotic arms via EtherNet/IP for precise speed and torque coordination.
- Water & Wastewater Treatment Plants – Integrating pump and blower drives into SCADA systems for remote monitoring, fault diagnostics, and energy optimization.
- Pulp & Paper Mills – Enabling real-time process control of winder and refiner drives through Allen-Bradley ControlLogix or CompactLogix PLCs.
- Oil & Gas Facilities – Connecting compressor and fan drives to DCS platforms for continuous process visibility and predictive maintenance.
- Food & Beverage Production – Coordinating mixer, pump, and conveyor drives in hygienic environments with deterministic network communication.
- Mining & Minerals Processing – Providing robust drive-to-controller communication in high-vibration, high-dust environments.
Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | FEIP-21 |
| ABB Order Code | 3AXD50000192793 |
| Compatible Drive Series | ABB ACS880 (all frame sizes) |
| Fieldbus Protocol | EtherNet/IP (CIP over Ethernet) |
| Network Speed | 10/100 Mbps, Auto-negotiation |
| Connector Type | RJ-45 (2 ports, daisy-chain capable) |
| Topology Support | Linear, Star, Ring (DLR) |
| Device Level Ring (DLR) | Supported |
| IP Address Assignment | DHCP / Static (configurable via drive panel) |
| Cyclic Data | Up to 12 words input / 12 words output |
| Acyclic Messaging | Explicit Messaging (Class 3) |
| Power Supply | Supplied via drive option slot (no external power required) |
| Operating Temperature | -10°C to +55°C |
| Storage Temperature | -40°C to +70°C |
| Humidity | 5–95% RH (non-condensing) |
| Weight | 450 g |
| Mounting | Drive option slot (plug-in, tool-free) |
| Firmware Upgradeable | Yes, via ABB Drive Composer |
Why Engineers Specify This Model
- Native ACS880 Integration – Designed exclusively for the ACS880 platform; no external gateway or converter required, reducing BOM cost and panel space.
- Device Level Ring (DLR) Support – Enables fault-tolerant ring topology, eliminating single points of network failure in critical production lines.
- Dual-Port RJ-45 – Supports daisy-chain wiring, simplifying cable routing and reducing switch port requirements in large drive arrays.
- Seamless PLC Integration – Pre-built EDS (Electronic Data Sheet) files available for Rockwell Automation Studio 5000, enabling rapid tag import and commissioning.
- Real-Time Parameter Access – Full read/write access to all ACS880 drive parameters over the network, enabling remote tuning and diagnostics without local panel access.
- Compact Plug-In Design – Tool-free installation into the drive option slot; no additional mounting hardware or wiring terminals required.
Complete System Bill of Materials
For a complete ACS880 EtherNet/IP networked drive system, engineers typically specify:
- ABB ACS880-01 / ACS880-07 Variable Frequency Drive (frame-size dependent on motor kW)
- ABB FEIP-21 (3AXD50000192793) – EtherNet/IP Adapter Module (this item)
- ABB ACS-AP-I or ACS-AP-W Assistant Control Panel (for local commissioning)
- Shielded Cat5e / Cat6 Ethernet cable (industrial grade, rated for flex/drag chain if required)
- Managed industrial Ethernet switch with DLR support (e.g., Cisco IE-2000, Stratix 5700)
- Rockwell ControlLogix / CompactLogix PLC with 1756-EN2T or equivalent EtherNet/IP scanner module
- ABB Drive Composer Pro software (for commissioning, parameter backup, and firmware updates)
Compliance & Industry Standards
- EtherNet/IP conformance tested – ODVA certified
- CE Marked (EU Machinery Directive, EMC Directive)
- UL Listed (UL 508C – Power Conversion Equipment)
- RoHS 2 compliant (Directive 2011/65/EU)
- IEC 61800-3 (EMC requirements for variable speed drive systems)
- IEC 61158 / IEC 61784 (Fieldbus communication standards)
Quality Assurance & Sourcing
Konmask.com sources ABB automation components through authorized distribution channels and verified industrial surplus networks. Every unit undergoes the following before dispatch:
- Visual inspection for physical damage, corrosion, and connector integrity
- Label and serial number verification against ABB part number 3AXD50000192793
- Functional power-on test where applicable
- Anti-static packaging with humidity indicator card
- Traceable documentation provided upon request
We stand behind every shipment. If a part does not match its specification, we resolve it — no bureaucratic delays.
How to Source This Part
- In Stock: Order directly on this page for same-day or next-business-day dispatch.
- Bulk / Project Quantity: Contact us for volume pricing and lead-time commitment — we support MRO and capital project procurement.
- Urgent Requirement: Email support@konmask.com or call +0086 19859288691 for expedited sourcing.
- Cross-Reference: This module is also referenced as FEIP21, 3AXD50000192793, ABB EtherNet/IP option module for ACS880.
Application-Specific FAQ
Q: Is the FEIP-21 compatible with ACS580 or ACS480 drives?
A: No. The FEIP-21 is designed exclusively for the ACS880 drive series. For ACS580, the correct module is FENA-21; for ACS480, use FENA-01.
Q: Can I use the FEIP-21 with a Siemens S7 PLC?
A: Yes. EtherNet/IP is an open standard. Siemens S7-1500 with a CP 1543-1 module supports EtherNet/IP scanner functionality and can communicate with the FEIP-21.
Q: Does the FEIP-21 support implicit (I/O) and explicit (messaging) communication simultaneously?
A: Yes. The module supports concurrent cyclic I/O (implicit) and explicit messaging, allowing real-time control alongside parameter read/write operations.
Q: What is the maximum number of FEIP-21 modules per ACS880 drive?
A: One FEIP-21 per drive. The ACS880 option slot 1 or slot 2 can be used; only one EtherNet/IP adapter is supported per drive unit.
Q: Is firmware update required after installation?
A: ABB recommends verifying firmware compatibility using Drive Composer Pro. Firmware updates are performed over the drive’s USB or Ethernet connection.
© 2026 Konmask.com. All rights reserved.