Bently Nevada 190501-02-99-00 – High-Output Piezoelectric Velocity Transducer | Velomitor CT Series
Engineering Background: The Velomitor CT (Compact Transducer) is Bently Nevada’s purpose-built piezoelectric velocity sensor engineered for continuous, online vibration monitoring of rotating and reciprocating machinery. Unlike traditional electrodynamic velocity sensors, the Velomitor CT uses an integrated electronic circuit to convert raw piezoelectric charge into a low-impedance velocity-proportional voltage signal, eliminating the mechanical resonance limitations of moving-coil designs.
Product Positioning: Part number 190501-02-99-00 is the standard industrial configuration of the Velomitor CT — featuring a 2-pin MIL-C-5015 connector, side-exit cable entry, and compatibility with Bently Nevada 3500 Series, System 1, and third-party monitoring platforms. It is the preferred sensor for engineers specifying API 670-compliant machinery protection systems on turbines, compressors, pumps, and motors.
Complete Technical Specifications
- Part Number: 190501-02-99-00
- Series / Platform: Velomitor CT (Compact Transducer)
- Manufacturer: Bently Nevada (Baker Hughes)
- Sensor Type: Piezoelectric Velocity Transducer (ICP® compatible)
- Measurement Parameter: Casing / Bearing Housing Vibration Velocity
- Sensitivity: 100 mV/in/s (3.937 mV/mm/s) ±5%
- Frequency Range: 2 Hz – 1,000 Hz (±3 dB)
- Amplitude Range: 0 – 50 in/s pk (0 – 1,270 mm/s pk)
- Resonant Frequency: ≥ 18,000 Hz
- Transverse Sensitivity: ≤ 5% of axial sensitivity
- Supply Voltage: 18 – 30 VDC (constant current excitation)
- Supply Current: 2 – 20 mA
- Output Bias Voltage: 8 – 14 VDC
- Output Impedance: ≤ 100 Ω
- Connector: 2-Pin MIL-C-5015 (side-exit)
- Housing Material: 316L Stainless Steel
- Mounting: ¼-28 UNF Stud (bottom), Magnetic / Adhesive optional
- Operating Temperature: -40°C to +121°C (-40°F to +250°F)
- Ingress Protection: IP67
- Weight: 380 g (approx.)
- Compliance: API 670, CE, RoHS
Proven Application Environments
- Steam and gas turbine bearing housing vibration monitoring
- Centrifugal and reciprocating compressor casing vibration
- Pump and motor vibration surveillance (API 670 systems)
- Bently Nevada 3500/22M Transient Data Interface inputs
- System 1 Condition Monitoring Software integration
- Third-party DCS / PLC vibration input cards (4–20 mA conversion via transmitter)
- Offshore and marine machinery protection panels
- Petrochemical plant rotating equipment health monitoring
Engineering Advantages
- No Moving Parts: Piezoelectric design eliminates mechanical wear, extending MTBF vs. electrodynamic sensors
- Wide Frequency Response: 2–1,000 Hz captures both low-speed machinery and high-frequency structural resonances in a single sensor
- High Shock Resistance: Survives 5,000 g shock — suitable for compressor valve decks and reciprocating machinery
- Low-Impedance Output: Drives long cable runs (up to 300 m) without signal degradation
- API 670 Compliant: Drop-in replacement for existing Bently Nevada machinery protection systems
- IP67 Sealed: Withstands wash-down, oil mist, and outdoor installation without additional enclosures
System Architecture & Signal Flow
The 190501-02-99-00 operates on a constant-current loop (2–20 mA, 18–30 VDC). The internal piezoelectric crystal generates a charge proportional to acceleration; the integrated ASIC differentiates and conditions this signal to produce a velocity-proportional voltage output. The bias voltage (8–14 VDC) rides on the signal line and is blocked by the monitoring system’s input coupling capacitor. Signal flow: Sensor → 2-pin MIL connector → field cable → Bently Nevada 3500 I/O module or third-party monitor input card → System 1 / DCS historian.
For 4–20 mA loop integration, pair with a Bently Nevada 3300/16 or equivalent velocity-to-current transmitter.
Sourcing & Quality Verification
- All units sourced from authorized distributors or verified OEM surplus channels
- Each unit inspected: housing integrity, connector pin condition, bias voltage output, and sensitivity verification
- Original Bently Nevada calibration documentation available upon request
- Traceability to Baker Hughes / Bently Nevada part number confirmed before shipment
- 30-day functional warranty on all stocked units
Procurement Process
- Step 1: Confirm part number 190501-02-99-00 matches your system’s connector and mounting requirements
- Step 2: Contact us for real-time stock availability and lead time — support@konmask.com | +0086 19859288691
- Step 3: Submit PO or request a proforma invoice; we accept T/T, L/C, and major credit cards
- Step 4: Units ship within 1–3 business days from Hong Kong warehouse; DHL / FedEx express available
- Step 5: Receive unit with inspection report and, where available, OEM calibration certificate
Technical FAQ
Q: Is the 190501-02-99-00 a direct replacement for the 190501-01-99-00?
A: The -02- suffix denotes the side-exit connector configuration vs. the -01- top-exit variant. Electrically identical; verify connector orientation before ordering.
Q: Can this sensor be used with non-Bently Nevada monitors?
A: Yes. Any monitor accepting a constant-current-powered ICP®/IEPE-compatible velocity input (100 mV/in/s) is compatible. Confirm supply current range (2–20 mA) with your monitor manufacturer.
Q: What cable is recommended for long runs?
A: Bently Nevada 330130 series low-noise coaxial cable or equivalent RG-58 with foil + braid shield. Maintain cable impedance ≤ 100 pF/m for runs exceeding 150 m.
Q: Does this sensor require periodic recalibration?
A: Bently Nevada recommends sensitivity verification every 2 years or per your plant’s machinery protection maintenance schedule (API 670 Annex D).
Q: What is the difference between Velomitor CT and Velomitor XA?
A: The Velomitor XA (190501-0X-00-00 series) extends the frequency range to 15,000 Hz for high-frequency structural analysis. The CT variant (this unit) is optimized for standard machinery protection per API 670.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691