Turbine Temperature Monitoring Solution – GE IS200VRTDH1DAC | Speedtronic Mark VI
Where This Product Is Used
The GE IS200VRTDH1DAC (also referenced as VRTD H1D) is a dedicated RTD (Resistance Temperature Detector) input card engineered for GE’s Speedtronic Mark VI turbine control platform. It is deployed in mission-critical environments where precise, real-time temperature measurement is essential for safe turbine operation:
- Gas Turbine Power Plants – Exhaust thermocouple/RTD monitoring on Frame 5, 6, 7, and 9 series GE gas turbines
- Combined Cycle Power Stations – Heat recovery steam generator (HRSG) temperature loop integration
- Steam Turbine Control Systems – Bearing metal temperature and steam inlet/exhaust monitoring
- Compressor Stations – Pipeline compressor train temperature supervision
- LNG & Petrochemical Plants – Process turbine temperature feedback in hazardous-area control rooms
- Marine Propulsion Systems – Shipboard gas turbine generator temperature management
Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | IS200VRTDH1DAC |
| Alternate Reference | VRTD H1D |
| Series | Speedtronic Mark VI |
| Manufacturer | GE (General Electric) |
| Card Function | RTD (Resistance Temperature Detector) Input |
| Input Channels | Multiple RTD inputs (Pt100 / Pt1000 compatible) |
| Communication Bus | Mark VI IONet / VME backplane |
| Operating Temperature | 0°C to +60°C |
| Form Factor | Single-width VME card |
| Weight | 420 g (approx.) |
| Condition | New / Refurbished / Tested Available |
Why Engineers Specify This Model
- Drop-in Mark VI Compatibility – Designed exclusively for the Mark VI I/O rack; no firmware patching or adapter required
- High-Resolution Temperature Accuracy – Supports Pt100 three-wire RTD inputs with hardware linearization, minimizing measurement drift in high-temperature turbine environments
- Redundancy-Ready Architecture – Supports TMR (Triple Modular Redundancy) configurations for SIL-rated turbine protection loops
- Proven Field Reliability – Widely deployed across GE Frame 7FA, 7EA, 9E, and 6B turbine fleets globally
- Reduced Downtime Risk – Stocked as a spare-parts module; hot-swap capability within Mark VI chassis minimizes planned outage windows
Complete System Bill of Materials
The IS200VRTDH1DAC is typically specified alongside the following Mark VI components:
- IS200VCMIH2C – Mark VI VME Communication Module
- IS200VSVOH1BAB – Servo Driver Output Card
- IS200VPWRH1MEB – Mark VI Power Supply Module
- IS200VTURH1BBB – Turbine Control Processor Card
- DS200TCQAG1BHF – Mark V/VI Terminal Board (RTD)
- IS200ECTBG1A – I/O Terminal Board for RTD wiring termination
Contact [email protected] for complete BOM sourcing assistance.
Compliance & Industry Standards
- Designed and tested to GE Speedtronic Mark VI engineering specifications
- Compatible with IEC 61511 functional safety requirements for turbine protection systems
- Suitable for installations governed by NFPA 85 (Boiler and Combustion Systems Hazards Code)
- Meets CE / RoHS directives for international export compliance
- Traceable to ISO 9001:2015 quality management standards through our supply chain
Quality Assurance & Sourcing
At Konmask.com, every GE Speedtronic module undergoes a structured verification process before shipment:
- ✅ Visual inspection for PCB damage, corrosion, and component integrity
- ✅ Firmware version verification against GE release documentation
- ✅ Functional bench test on Mark VI-compatible test rack where applicable
- ✅ Anti-static packaging with humidity indicator card
- ✅ Traceable lot documentation and certificate of conformance available on request
We source from decommissioned power plant inventories, authorized distributors, and OEM surplus channels — ensuring authenticity and traceability.
How to Source This Part
- Confirm your Mark VI rack slot and firmware revision – Share your existing VRTD card label or Mark VI project configuration file
- Request a quote – Email [email protected] or call +0086 19859288691 with your required quantity and delivery timeline
- Receive availability confirmation – We respond within 1 business day with stock status, lead time, and pricing in your preferred currency
- Place order & ship – DHL / FedEx express worldwide; export documentation (CO, packing list, commercial invoice) included
Application-Specific FAQ
Q: Is the IS200VRTDH1DAC compatible with Mark VIe?
A: The VRTDH1D is a Mark VI-series card. Mark VIe uses a different I/O architecture (IONET Ethernet-based). Please confirm your controller generation before ordering.
Q: Can this card replace an IS200VRTDH1CAC or IS200VRTDH1BAC?
A: Hardware revision suffixes (B, C, D) may indicate minor PCB changes. Functional compatibility is typically maintained, but we recommend verifying with your GE service engineer or sharing your system configuration for confirmation.
Q: What RTD sensor types are supported?
A: The card is designed for Pt100 (100Ω at 0°C) three-wire RTD inputs, which are standard in GE turbine exhaust and bearing temperature circuits.
Q: Do you offer exchange / repair services?
A: Yes. We offer board-level repair and exchange programs for IS200VRTDH1DAC. Contact us with your faulty unit details for a repair quotation.
Q: What is the lead time for in-stock units?
A: In-stock units ship within 1–3 business days. For sourced units, typical lead time is 2–4 weeks depending on origin.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: [email protected] | +0086 19859288691