Process Automation Solution – Honeywell 2MLI-D22A | TDC-3000 Series
Where This Product Is Used
The Honeywell 2MLI-D22A Digital Input Module is a discrete I/O card designed for the Honeywell TDC-3000 Distributed Control System (DCS). It is widely deployed in:
- Oil & Gas refineries – monitoring valve position feedback, pump run/stop status, and ESD trip signals
- Chemical & Petrochemical plants – reading discrete field device states across multi-loop process units
- Power generation facilities – capturing turbine and boiler interlock status signals
- Pulp & Paper mills – integrating motor control center (MCC) status into the DCS historian
- Pharmaceutical manufacturing – acquiring binary signals from cleanroom equipment for batch record compliance
Wherever a TDC-3000 backbone is in service, the 2MLI-D22A provides the discrete input capacity that keeps process visibility intact.
Technical Specifications
- Part Number: 2MLI-D22A
- Manufacturer: Honeywell Process Solutions
- Series: TDC-3000 / PM (Process Manager) I/O
- Module Type: Digital (Discrete) Input
- Input Channels: 16 discrete input channels (per standard 2MLI-D22A configuration)
- Signal Type: Dry contact / wet contact discrete inputs
- Communication: Local Control Network (LCN) backplane interface
- Form Factor: Card-style module for TDC-3000 I/O chassis
- Operating Temperature: 0 °C to 60 °C (32 °F to 140 °F)
- Approvals: CE, UL (refer to Honeywell datasheet for full certification list)
- Weight: Approx. 100 g (card only, without termination assembly)
Always verify specifications against the official Honeywell product datasheet before engineering design-in.
Why Engineers Specify This Model
- Direct TDC-3000 compatibility – plug-in replacement with no firmware re-configuration required in most applications
- Proven field reliability – the TDC-3000 platform has decades of continuous service in tier-1 process facilities worldwide
- Reduced downtime risk – sourcing a genuine 2MLI-D22A avoids the integration risk of cross-brand substitutes
- Simplified spares management – standardized card form factor allows a single spare to cover multiple I/O slots
- Long lifecycle support – Honeywell’s extended support programs keep legacy TDC-3000 assets operational beyond standard EOL dates
Complete System Bill of Materials
For a fully operational TDC-3000 digital input circuit, engineers typically specify:
- Honeywell 2MLI-D22A – Digital Input Module (this item)
- TDC-3000 I/O Chassis / Card File (e.g., MC-PAIH03 or equivalent)
- Termination Assembly / Field Termination Panel (FTA) matched to 2MLI-D22A
- LCN Cable and connectors for backplane communication
- 24 VDC field power supply for wet-contact input loops
- Surge protection barriers (recommended for field wiring in hazardous areas)
Contact support@konmask.com for a complete BOM quotation.
Compliance & Industry Standards
- IEC 61511 – Functional Safety for the Process Industry (SIS integration guidance)
- IEC 61131-2 – Programmable Controllers: Equipment Requirements and Tests
- NAMUR NE 21 – EMC requirements for process control equipment
- CE Marking – European conformity for electrical equipment
- RoHS – Restriction of Hazardous Substances (verify lot date with Honeywell)
Quality Assurance & Sourcing
Konmask.com specializes in genuine, traceable industrial automation components for DCS, PLC, and process control applications. Every 2MLI-D22A unit we supply is:
- Inspected for physical integrity and label authenticity prior to dispatch
- Stored in ESD-safe, climate-controlled warehousing
- Shipped with full traceability documentation upon request
- Backed by our sourcing guarantee – if a part does not perform as specified, we resolve it
We do not supply counterfeit, refurbished-as-new, or unverified grey-market stock.
How to Source This Part
- Add to cart directly on this page for standard lead times
- Request a quote for volume orders (>5 units) or expedited delivery – email support@konmask.com
- Provide your PO or project number for B2B invoicing and customs documentation
- Specify shipping Incoterms (EXW, FOB, CIF) if required for your procurement process
Lead time: typically 3–10 business days depending on stock availability. Contact us for urgent requirements.
Application-Specific FAQ
Q: Is the 2MLI-D22A compatible with both TDC-3000 and Experion PKS systems?
A: The 2MLI-D22A is a TDC-3000 series card. Experion PKS uses a different I/O architecture (Series C / CHARM). Confirm your system generation before ordering.
Q: Can this module be hot-swapped in a live TDC-3000 chassis?
A: Hot-swap capability depends on your specific chassis revision and system configuration. Consult your Honeywell system documentation or contact our technical team for guidance.
Q: Do you provide a certificate of conformance (CoC) with the shipment?
A: Yes. CoC and inspection records are available upon request at time of order.
Q: What is the difference between 2MLI-D22A and similar Honeywell digital input cards?
A: The 2MLI-D22A designation identifies a specific channel count and signal conditioning configuration within the TDC-3000 I/O family. Cross-reference your existing card label and system I/O list before substituting.
Q: Can you supply the matching termination assembly?
A: Yes. Contact us with your full I/O list and we will identify the correct FTA part number to pair with the 2MLI-D22A.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691