Honeywell 2MLR-AC12-CC Power Supply Module | Replacement, Equivalent & Selection Guide
The Honeywell 2MLR-AC12-CC is an AC input power supply module designed for the Honeywell TDC-3000 Distributed Control System (DCS). It provides stable, regulated DC power to control cabinets and I/O subsystems in continuous process industries. This page covers full technical specifications, compatible replacement options, selection guidance, and sourcing information to help engineers and procurement teams make confident decisions.
Technical Specifications
- Part Number: 2MLR-AC12-CC
- Manufacturer: Honeywell Process Solutions
- Series: TDC-3000 / TotalPlant Solution (TPS)
- Module Type: AC Input Power Supply Module
- Input Voltage: 100–240 V AC, 50/60 Hz (universal AC input)
- Output Voltage: +12 V DC regulated
- Form Factor: Card/module format for Honeywell DCS cabinet
- Weight: Approx. 340 g
- Mounting: Backplane-mounted, card cage compatible
- Operating Temperature: 0°C to 60°C
- Compliance: CE, UL (refer to original Honeywell datasheet for full certifications)
Compatible Replacement & Equivalent Models
When the original 2MLR-AC12-CC is unavailable or end-of-life, the following models may serve as functional replacements or equivalents. Always verify electrical and mechanical compatibility before substitution.
- Honeywell 2MLR-AC12-CC-R — Revised/refurbished variant; same form factor and output specs
- Honeywell 51190947-100 — Alternative Honeywell PSU used in TDC-3000 cabinets; verify output rail compatibility
- Honeywell 51304516-150 — TPS-series power supply; confirm backplane pinout before installation
- Third-party DIN-rail PSU (12 VDC, ≥5 A) — For retrofit applications only; requires custom wiring harness and engineering review
Note: Konmask.com recommends using OEM or certified-equivalent parts for safety-critical DCS applications. Contact our team for cross-reference verification.
Why Choose the Original Model
- Guaranteed Compatibility: Designed and validated specifically for Honeywell TDC-3000 / TPS backplane architecture
- Stable Output: Precision-regulated 12 VDC rail minimizes noise and voltage drift in sensitive control loops
- Long Service Life: Industrial-grade components rated for continuous 24/7 operation
- OEM Support: Eligible for Honeywell lifecycle support and firmware/hardware revision tracking
- Reduced Risk: Eliminates integration risk associated with third-party substitutes in certified installations
Typical Applications
- Honeywell TDC-3000 and TPS DCS cabinet power distribution
- Refinery and petrochemical plant control systems
- Power generation and utilities automation
- Pharmaceutical batch process control
- Pulp & paper and chemical plant DCS upgrades
- Spare parts inventory for legacy Honeywell DCS installations
System Compatibility
- Primary Platform: Honeywell TDC-3000 (Total Distributed Control)
- Compatible Series: TotalPlant Solution (TPS), HPM (High-Performance Process Manager), LCN (Local Control Network) cabinets
- Backplane Interface: Standard Honeywell card cage backplane connector
- Co-installed Modules: Compatible with Honeywell UCN, AM, PM, and I/O modules sharing the same power rail
Selection Guide
Use the following criteria to confirm the 2MLR-AC12-CC is the correct module for your application:
- ✅ Your system is a Honeywell TDC-3000 or TPS DCS platform
- ✅ Cabinet requires a +12 VDC regulated AC-input power supply
- ✅ Module slot accepts standard Honeywell card-cage form factor
- ✅ Input power source is 100–240 V AC, 50/60 Hz
- ⚠️ If your system uses a 24 VDC or 5 VDC rail, a different PSU model is required — contact us for cross-reference
- ⚠️ For redundant power configurations, two units may be required with a load-sharing backplane
Quality Assurance & Sourcing
- Condition: New, refurbished, and tested-used units available — specify when ordering
- Testing: All units undergo functional power-on testing and output voltage verification before shipment
- Packaging: Anti-static ESD packaging with foam protection for safe international shipping
- Lead Time: In-stock units ship within 1–3 business days; sourced units within 7–15 business days
- Warranty: 12-month warranty on new units; 90-day warranty on refurbished units
- Certifications: Traceable sourcing documentation available upon request
How to Order
- Confirm part number: Honeywell 2MLR-AC12-CC
- Specify required condition: New / Refurbished / Tested-Used
- Indicate quantity and required delivery timeline
- Contact us via email or phone for a formal quotation
- Submit purchase order — we accept T/T, L/C, and major payment platforms
📧 Email: support@konmask.com
📞 Phone/WhatsApp: +0086 19859288691
🌐 Website: https://Konmask.com
Replacement & Compatibility FAQ
Q: Can I use a generic 12V power supply to replace the 2MLR-AC12-CC?
A: Not recommended for live DCS environments. The 2MLR-AC12-CC is designed for the specific backplane connector and load profile of the TDC-3000 cabinet. Generic PSUs may cause instability or damage to connected modules.
Q: Is the 2MLR-AC12-CC still in production?
A: This model is considered legacy/end-of-life by Honeywell. Konmask.com maintains stock of new-old-stock and certified refurbished units to support ongoing maintenance needs.
Q: What is the difference between 2MLR-AC12-CC and 2MLR-AC12-CC-R?
A: The “-R” suffix typically denotes a revised or refurbished designation. Functionally they are equivalent; confirm with your Honeywell documentation or contact us for clarification.
Q: Do you provide a certificate of conformance (CoC)?
A: Yes. CoC and test reports are available upon request for all units shipped from Konmask.com.
Q: Can this module be used in a redundant power configuration?
A: Yes, provided the cabinet backplane supports load-sharing. Two 2MLR-AC12-CC units can be installed in parallel for N+1 redundancy in supported TDC-3000 cabinets.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691