Honeywell CC-TCF901 (51308301-175) Control Firewall Module | Replacement, Equivalent & Selection Guide
The Honeywell CC-TCF901 (part number 51308301-175) is a dedicated Control Firewall Module designed for use within Honeywell’s Experion PKS and C300 DCS architectures. It provides hardware-enforced network segmentation between the control network and higher-level supervisory or enterprise networks, ensuring process integrity and cybersecurity compliance in critical industrial environments.
At Konmask.com, we supply genuine, tested, and certified CC-TCF901 modules alongside verified compatible alternatives — helping engineers and procurement teams make confident, cost-effective sourcing decisions.
Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | CC-TCF901 / 51308301-175 |
| Manufacturer | Honeywell Process Solutions |
| Module Type | Control Firewall Module |
| Platform Compatibility | Experion PKS, C300 Controller Series |
| Communication Interface | FTE (Fault Tolerant Ethernet) |
| Network Segmentation | Control Network ↔ Supervisory / Enterprise Network |
| Mounting | Standard Honeywell I/O chassis / cabinet rail |
| Power Supply | Supplied via chassis backplane |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Weight | Approx. 180 g |
| Certifications | CE, UL (refer to Honeywell datasheet for full listing) |
| Firmware | Compatible with Experion R400 and above |
Compatible Replacement & Equivalent Models
When the original CC-TCF901 is unavailable, end-of-life, or cost-prohibitive, the following alternatives may be evaluated depending on system revision and firmware version:
| Model | Manufacturer | Compatibility Notes |
|---|---|---|
| CC-TCF901 Rev. B/C | Honeywell | Direct drop-in; verify firmware revision match |
| 51308301-175 (alternate label) | Honeywell | Same module, alternate part label — fully interchangeable |
| CC-TCF901 (refurbished) | Certified 3rd-party | Suitable for non-SIL applications; requires factory reset and re-commissioning |
| Honeywell CC-TCNT01 | Honeywell | Newer generation network termination; confirm chassis compatibility before substitution |
⚠ Always validate hardware revision and firmware compatibility with your Honeywell system integrator before substitution in safety-critical loops.
Why Choose the Original Model
- Hardware-enforced security: Dedicated firewall logic prevents unauthorized cross-network traffic at the hardware level — not reliant on software patches.
- Seamless Experion PKS integration: Factory-configured for plug-and-play deployment within certified Honeywell cabinets.
- Redundancy support: Supports redundant FTE network topologies for high-availability process control.
- Regulatory compliance: Meets IEC 62443 and ISA-99 industrial cybersecurity standards when deployed per Honeywell guidelines.
- Long service life: Designed for 24/7 continuous operation in harsh industrial environments.
Typical Applications
- Oil & gas refining and upstream production control systems
- Chemical and petrochemical plant DCS networks
- Power generation and utilities (SCADA/DCS hybrid architectures)
- Pharmaceutical manufacturing with 21 CFR Part 11 compliance requirements
- Pulp & paper and mining process control
- Water treatment and municipal infrastructure automation
System Compatibility
| System / Platform | Compatibility |
|---|---|
| Honeywell Experion PKS R400+ | ✅ Fully compatible |
| Honeywell C300 Controller | ✅ Fully compatible |
| Honeywell Experion R300 | ⚠ Verify firmware; may require update |
| Honeywell TDC 3000 | ❌ Not compatible — different architecture |
| Third-party DCS (ABB, Emerson, Siemens) | ❌ Not compatible — proprietary protocol |
Selection Guide
Use the following decision framework to select the correct module for your application:
- Confirm your Experion PKS revision — R400 and above are fully supported. R300 may require a firmware upgrade.
- Identify chassis slot availability — CC-TCF901 occupies one standard I/O chassis slot.
- Determine redundancy requirement — For high-availability systems, order two units for primary/secondary FTE redundancy.
- Assess cybersecurity compliance scope — If IEC 62443 SL2+ is required, use only genuine Honeywell modules with current firmware.
- Evaluate refurbished vs. new — Refurbished units are acceptable for non-critical monitoring loops; new units are recommended for safety-instrumented systems (SIS).
- Check lead time vs. urgency — Konmask.com maintains in-stock inventory for rapid dispatch; contact us for expedited shipping options.
Quality Assurance & Sourcing
- All modules are sourced from authorized distributors or directly from Honeywell-certified supply chains.
- Each unit undergoes functional verification testing prior to dispatch.
- Genuine modules ship with original Honeywell packaging, documentation, and traceability records.
- Refurbished units are clearly labeled and include a 90-day functional warranty.
- Export compliance screening performed on all international orders (EAR / ECCN classification available on request).
How to Order
- Add the CC-TCF901 to your cart and proceed to checkout, or
- Contact our technical sales team for bulk pricing, lead time confirmation, or custom sourcing:
📧 support@konmask.com
📞 +0086 19859288691 - Provide your Experion PKS revision and chassis model for compatibility pre-verification at no charge.
- Request a formal quotation (RFQ) for orders of 3+ units.
Replacement & Compatibility FAQ
Q: Can I use a refurbished CC-TCF901 in a safety-instrumented system (SIS)?
A: We do not recommend refurbished modules for SIL-rated loops. Use only new, traceable Honeywell-certified units in SIS applications.
Q: Is the 51308301-175 part number the same as CC-TCF901?
A: Yes. 51308301-175 is Honeywell’s internal manufacturing part number for the CC-TCF901 module. They are the same physical product.
Q: What is the lead time for in-stock units?
A: In-stock units typically ship within 1–3 business days. Contact us to confirm current availability before placing time-critical orders.
Q: Do you provide a certificate of conformance (CoC)?
A: Yes. A CoC is available for all genuine Honeywell modules upon request at time of order.
Q: Can this module be used with Emerson DeltaV or ABB 800xA?
A: No. The CC-TCF901 uses Honeywell’s proprietary FTE protocol and is not compatible with third-party DCS platforms.
Q: What happens if I install a mismatched firmware revision?
A: The Experion PKS system will flag a hardware mismatch alarm. Always verify firmware compatibility with your Honeywell system engineer before installation.
© 2026 Konmask.com. All rights reserved.