Honeywell MTL5575 Temperature Converter | Replacement, Equivalent & Selection Guide
The Honeywell MTL5575 is a DIN rail-mounted temperature converter from the MTL5000 series, designed to accept thermocouple and RTD inputs and transmit a 4–20 mA analog output signal to PLCs, DCS controllers, and SCADA systems. This page provides full technical specifications, compatible replacement models, and a structured selection guide to help industrial buyers source the right unit with confidence.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | MTL5575 |
| Brand / Manufacturer | Honeywell (MTL Instruments) |
| Series | MTL5000 |
| Function | Temperature Converter (Thermocouple / RTD Input) |
| Output Signal | 4–20 mA analog |
| Input Types | Thermocouple (J, K, T, E, R, S, B, N) / RTD (Pt100) |
| Mounting | DIN rail (35 mm) |
| Supply Voltage | 24 V DC (nominal) |
| Isolation | Galvanic isolation between input, output, and supply |
| Hazardous Area | Suitable for Zone 1 / Zone 2 (intrinsically safe input) |
| Approvals | ATEX, IECEx (refer to datasheet for full certification list) |
| Weight | ~300 g |
| Country of Origin | — |
Always verify specifications against the official Honeywell MTL5575 datasheet before final design-in.
Compatible Replacement & Equivalent Models
The following models are commonly evaluated as functional replacements or equivalents for the MTL5575. Verify electrical and mechanical compatibility before substitution.
| Model | Brand | Notes |
|---|---|---|
| MTL5575 | Honeywell / MTL | Original OEM unit |
| MTL4575 | Honeywell / MTL | MTL4000 series equivalent; different supply voltage range |
| 9202 | Pepperl+Fuchs | Thermocouple / RTD converter; verify output range |
| KFD2-UT2-Ex1 | Pepperl+Fuchs | HART-capable; check loop power requirements |
| IM35-11Ex-HI/24VDC | Phoenix Contact | DIN rail temperature transmitter; verify input type |
| MACX MCR-T-UI-UP | Phoenix Contact | Universal input; wider supply range |
| STT25H | Honeywell | Head-mount transmitter; different form factor |
Note: Konmask.com supplies genuine Honeywell MTL5575 units. Third-party equivalents listed above are for reference only.
Why Choose the Original Model
- Proven field reliability in hazardous-area process plants worldwide
- Full ATEX / IECEx certification maintained with original documentation
- Seamless integration with existing MTL5000 series backplanes and power supplies
- Guaranteed interoperability with Honeywell Experion, Yokogawa CENTUM, ABB 800xA, and other major DCS platforms
- Long-term spare-parts availability through authorized distribution channels
Typical Applications
- Oil & gas upstream / downstream process control
- Chemical and petrochemical plant instrumentation
- Power generation temperature monitoring loops
- Pharmaceutical batch process control
- Water treatment and utilities SCADA systems
- Hazardous-area DCS / PLC I/O marshalling cabinets
System Compatibility
The MTL5575 is designed to interface with standard 4–20 mA analog input cards across all major control platforms:
- Honeywell Experion PKS / TDC 3000
- Emerson DeltaV / Fisher ROC
- Yokogawa CENTUM VP / ProSafe
- ABB System 800xA / AC500
- Siemens SIMATIC S7 / PCS 7
- Rockwell Automation ControlLogix / PlantPAx
- Schneider Electric Modicon M340 / Foxboro
Selection Guide
Use the following criteria to confirm the MTL5575 is the correct choice for your application:
| Selection Criterion | MTL5575 Capability |
|---|---|
| Input sensor type | Thermocouple (multi-type) or Pt100 RTD |
| Output signal | 4–20 mA (2-wire loop) |
| Hazardous area classification | Zone 1 / Zone 2 (ATEX / IECEx) |
| Mounting format | 35 mm DIN rail |
| Supply voltage | 24 V DC |
| Galvanic isolation required | Yes – input / output / supply isolated |
| HART pass-through required | No (use MTL5575H for HART) |
If your application requires HART communication, consider the MTL5575H. For non-hazardous areas, the MTL4575 may offer a cost advantage.
Quality Assurance & Sourcing
- All units sourced through verified industrial supply chains
- Original manufacturer packaging and documentation supplied where available
- Batch traceability records available on request
- Pre-shipment functional inspection available for critical orders
- Export compliance and customs documentation supported for international orders
How to Order
- Confirm part number: MTL5575
- Specify required quantity
- Contact us via email or phone for stock availability and lead time
- Request a formal quotation — we respond within 1 business day
- Provide shipping destination for accurate freight cost calculation
📧 support@konmask.com | 📞 +0086 19859288691
Replacement & Compatibility FAQ
Q: Can the MTL5575 replace an MTL4575 directly?
A: Not directly — the MTL4000 and MTL5000 series use different backplane connectors and supply voltage ranges. Verify mechanical and electrical compatibility before substitution.
Q: Is the MTL5575 suitable for SIL-rated safety loops?
A: The MTL5575 is not independently SIL-rated. For functional safety applications, consult Honeywell for SIL-capable alternatives within the MTL range.
Q: What is the difference between MTL5575 and MTL5575H?
A: The MTL5575H adds HART signal pass-through capability, allowing digital communication with HART-enabled field instruments over the same 4–20 mA loop.
Q: Can Konmask.com supply original Honeywell MTL5575 units?
A: Yes. Contact us with your quantity and delivery requirements for a prompt quotation.
Q: What certifications does the MTL5575 carry?
A: ATEX and IECEx for hazardous area use. Refer to the official Honeywell datasheet for the complete approval list.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691