Bently Nevada 190501-10-00-01 – High-Sensitivity Piezoelectric Velocity Transducer | Velomitor CT Platform
Engineering Background: The Velomitor CT series represents Bently Nevada’s field-proven approach to continuous velocity-based vibration monitoring on rotating and reciprocating machinery. Unlike traditional seismic velocity sensors that rely on moving coil assemblies, the Velomitor CT employs a solid-state piezoelectric element integrated with an internal signal-conditioning circuit, eliminating mechanical wear and delivering consistent, low-noise output across its full operating life.
Product Positioning: The 190501-10-00-01 is a compact, top-exit cable configuration Velomitor CT transducer designed for direct integration with Bently Nevada 3500 Series machinery protection racks and compatible monitoring systems. It is the preferred choice for procurement engineers specifying continuous online vibration monitoring on turbines, compressors, pumps, fans, and gearboxes where API 670 compliance is required.
Complete Technical Specifications
| Parameter | Value |
|---|---|
| Part Number / SKU | 190501-10-00-01 |
| Series / Platform | Velomitor CT (Bently Nevada) |
| Sensor Technology | Piezoelectric (solid-state, no moving parts) |
| Measurement Type | Casing / Structural Velocity (vibration) |
| Sensitivity | 100 mV/in/s (3.937 mV/mm/s) |
| Frequency Range | 2 Hz – 1,000 Hz (±3 dB) |
| Amplitude Range | 0 – 50 in/s pk (0 – 1,270 mm/s pk) |
| Supply Voltage | 18 – 30 VDC (constant current loop) |
| Bias Voltage Output | 10 – 14 VDC (nominal 12 VDC) |
| Current Consumption | 2 – 10 mA |
| Output Impedance | < 100 Ω |
| Transverse Sensitivity | < 5% of axial sensitivity |
| Operating Temperature | -40 °C to +121 °C (-40 °F to +250 °F) |
| Humidity | 0 – 100% RH (non-condensing) |
| Enclosure Rating | IP67 (dust-tight, immersion-resistant) |
| Housing Material | 316 Stainless Steel |
| Mounting Thread | 1/4-28 UNF (stud mount) |
| Cable Exit | Top exit, integral armored cable |
| Connector | 2-pin MIL-C-5015 style |
| Weight | Approx. 320 g (with cable) |
| Compliance | API 670, CE, RoHS |
| Country of Origin | USA |
Proven Application Environments
- Steam & Gas Turbines: Continuous casing vibration monitoring per API 670 requirements; direct wiring to 3500/42M velocity input modules.
- Centrifugal Compressors: Bearing housing velocity measurement for early-warning fault detection on high-speed rotating equipment.
- Reciprocating Compressors: Frame and cylinder velocity monitoring; compatible with 3500/77M reciprocating compressor monitor.
- Pumps & Fans: Structural vibration trending on balance-of-plant rotating equipment; suitable for ATEX Zone 2 installations with appropriate barriers.
- Gearboxes: High-frequency velocity capture for gear mesh and bearing defect frequencies up to 1,000 Hz.
- Power Generation: OEM-specified on GE, Siemens, and MHI turbine packages; drop-in replacement for legacy seismic velocity sensors.
Engineering Advantages
- Solid-State Reliability: No moving coil or magnet assembly — immune to mechanical fatigue, corrosion of internal springs, and orientation sensitivity that affect traditional velocity sensors.
- Wide Dynamic Range: 0–50 in/s pk amplitude range covers both normal operating vibration and high-amplitude trip events without signal clipping.
- Low-Noise Floor: Internal ASIC signal conditioning delivers <0.01 in/s rms broadband noise, enabling detection of early-stage bearing defects.
- Direct 3500 System Compatibility: 4–20 mA / voltage output compatible with 3500/42M, 3500/45, and 3500/46M input modules — no external signal conditioner required.
- Rugged IP67 Enclosure: 316 SS housing withstands wash-down, steam purging, and outdoor installation without additional protection.
- Long Service Life: MTBF >100,000 hours; no periodic recalibration required under normal operating conditions.
System Architecture & Signal Flow
The 190501-10-00-01 operates as a two-wire, constant-current-loop device. The internal piezoelectric element converts mechanical velocity (integrated from acceleration) into a proportional charge signal, which is amplified and buffered by the internal ASIC. The resulting voltage output (100 mV/in/s) is superimposed on the DC bias voltage and transmitted over the two-wire cable to the monitoring system input module.
Typical wiring path: Transducer → Armored cable → Junction box (optional) → 3500 rack I/O module (3500/42M or equivalent) → System monitor / DCS / historian.
The sensor is powered directly by the monitoring system’s constant-current supply (18–30 VDC, 2–10 mA). No external power supply or signal conditioner is required in standard Bently Nevada 3500 installations.
Sourcing & Quality Verification
- All units supplied by Konmask.com are sourced from authorized distributors or verified surplus channels with full traceability documentation.
- Each unit undergoes incoming inspection including visual examination, dimensional verification, and functional bias-voltage check prior to shipment.
- Original manufacturer documentation (datasheet, calibration certificate where available) is included with every shipment.
- Counterfeit-risk mitigation: serial number and date code verification performed against Bently Nevada manufacturing records where accessible.
- Packaging: anti-static bag + foam-lined carton; meets ASTM D4169 shipping performance requirements.
Procurement Process
- Confirm Part Number: Verify 190501-10-00-01 against your system BOM or Bently Nevada 3500 rack configuration drawing.
- Request Quote: Contact support@konmask.com with quantity, required delivery date, and destination port/Incoterm.
- Review & Accept: Receive formal quotation with lead time, unit price, and shipping options within 24 business hours.
- Place Order: Submit PO via email or online checkout; T/T, L/C, and credit card accepted.
- Shipment & Tracking: Units ship within 3–7 business days; DHL/FedEx/UPS tracking number provided upon dispatch.
- After-Sales Support: 12-month warranty against manufacturing defects; technical support available via email and WhatsApp.
Technical FAQ
Q: Is the 190501-10-00-01 a direct replacement for the 190501-10-00-00?
A: Yes. The -01 suffix denotes a minor revision to the internal ASIC firmware; all mechanical dimensions, electrical interface, and performance specifications are identical. It is a drop-in replacement.
Q: Can this transducer be used with non-Bently Nevada monitoring systems?
A: Yes, provided the monitoring system supplies a compatible constant-current loop (18–30 VDC, 2–10 mA) and accepts a voltage output signal. Signal conditioning may be required for systems expecting 4–20 mA input.
Q: What is the maximum cable length between the transducer and the monitoring rack?
A: Bently Nevada specifies a maximum cable capacitance of 3,000 pF. Using standard Bently Nevada armored cable (approx. 30 pF/ft), this equates to approximately 100 ft (30 m). Longer runs require low-capacitance cable or a remote power unit.
Q: Is ATEX/IECEx certification available for this model?
A: The standard 190501-10-00-01 is not intrinsically safe. For hazardous area installations, use with an approved Zener barrier or galvanic isolator, or specify the ATEX-rated variant (190501-10-00-CN or equivalent).
Q: What is the recommended mounting torque?
A: 15–20 ft-lb (20–27 N·m) on a clean, flat, unpainted metal surface. Use a stainless steel stud (1/4-28 UNF) with thread-locking compound for permanent installations.
© 2026 Konmask.com. All rights reserved.
Original Source: https://Konmask.com
Contact: support@konmask.com | +0086 19859288691